Johannes Schrittwieser
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Johannes Schrittwieser has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Ursula Schmidt-Erfurth
Medical University of Vienna
5 shared publications - Gregor Sebastian Reiter
Medical University of Vienna
4 shared publications - Hrvoje Bogunović
Medical University of Vienna
3 shared publications - Klaudia Birner
Department of Ophthalmology and Optometry Medical University of Vienna Vienna Austria
3 shared publications Markus Gumpinger
3 shared publications- Anna Eidenberger
Department of Ophthalmology and Optometry Medical University of Vienna Vienna Austria
2 shared publications
Latest Publications
- Open Access
- 29 July 2026
- Published by Wiley in Acta Ophthalmologica
Systematic quantification of outer retinal morphology in three different SD ‐ OCT devices in geographic atrophy
Purpose: To define interdevice differences in quantitative outer retinal biomarkers across three spectral‐domain (SD) optical coherence tomography (OCT) devices in geographic atrophy (GA). Methods: Patients with GA prospectively underwent imaging using Spectralis (Heidelberg Engineering), Cirrus (Zeiss) and Maestro (Topcon) OCT devices. Ellipsoid zone (EZ) and outer nuclear layer (ONL) thickness, as well as EZ and retinal pigment epithelium (RPE) loss, were automatically pre‐segmented and manually corrected. Quantitative measurements were compared between OCT devices using anova or Friedman tests. Bland–Altman analysis determined mean differences and 95% limits of agreement (LoA). Results: A total of 7080 B‐scans from 120 OCT volumes of 40 eyes were analysed. Mean patient age was 80 ± 7 years. Mean EZ thickness in the 6‐mm macular cube was 34.8 ± 4.6, 33.4 ± 4.1 and 31.0 ± 4.8 μm for Spectralis, Cirrus and Maestro, respectively, while mean ONL thickness was 77.8 ± 9.2, 78.5 ± 9.4 and 75.8 ± 9.6 μm. Interdevice differences were significant for EZ and ONL‐thickness (all p < 0.05). Mean EZ thickness bias ranged from 1.5 to 3.8 μm, with the widest LoA between Spectralis and Maestro. Mean ONL‐thickness bias ranged from −0.7 to 2.7 μm, with the widest LoA between Cirrus and Maestro. EZ‐loss and EZ/RPE‐loss‐area also differed significantly (both p < 0.01). Conclusion: Visualization and quantification of atrophic features at the level of the photoreceptors, including EZ thickness, EZ loss and ONL thickness, are influenced by the implemented OCT machine. Consistency in the OCT device during patient monitoring allows for the highest precision and eliminates interdevice differences in quantitative outcome measures.
- 29 July 2026
- Published by Wiley in Acta Ophthalmologica
Open AccessSystematic quantification of outer retinal morphology in three different SD ‐ OCT devices in geographic atrophy
Purpose: To define interdevice differences in quantitative outer retinal biomarkers across three spectral‐domain (SD) optical coherence tomography (OCT) devices in geographic atrophy (GA). Methods: Patients with GA prospectively underwent imaging using Spectralis (Heidelberg Engineering), Cirrus (Zeiss) and Maestro (Topcon) OCT devices. Ellipsoid zone (EZ) and outer nuclear layer (ONL) thickness, as well as EZ and retinal pigment epithelium (RPE) loss, were automatically pre‐segmented and manually corrected. Quantitative measurements were compared between OCT devices using anova or Friedman tests. Bland–Altman analysis determined mean differences and 95% limits of agreement (LoA). Results: A total of 7080 B‐scans from 120 OCT volumes of 40 eyes were analysed. Mean patient age was 80 ± 7 years. Mean EZ thickness in the 6‐mm macular cube was 34.8 ± 4.6, 33.4 ± 4.1 and 31.0 ± 4.8 μm for Spectralis, Cirrus and Maestro, respectively, while mean ONL thickness was 77.8 ± 9.2, 78.5 ± 9.4 and 75.8 ± 9.6 μm. Interdevice differences were significant for EZ and ONL‐thickness (all p < 0.05). Mean EZ thickness bias ranged from 1.5 to 3.8 μm, with the widest LoA between Spectralis and Maestro. Mean ONL‐thickness bias ranged from −0.7 to 2.7 μm, with the widest LoA between Cirrus and Maestro. EZ‐loss and EZ/RPE‐loss‐area also differed significantly (both p < 0.01). Conclusion: Visualization and quantification of atrophic features at the level of the photoreceptors, including EZ thickness, EZ loss and ONL thickness, are influenced by the implemented OCT machine. Consistency in the OCT device during patient monitoring allows for the highest precision and eliminates interdevice differences in quantitative outcome measures.
- Open Access
- 29 April 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (9) , 3392
Choriocapillaris Flow-Enriched Prediction of Retinal Sensitivity Using OCT-Derived Biomarkers in Intermediate Age-Related Macular Degeneration
Objectives: To assess the association of structural biomarkers derived from optical coherence tomography (OCT) and choriocapillaris (CC) flow information with point-wise retinal sensitivity (PWS) measured by microperimetry (MP) in intermediate age-related macular degeneration (iAMD). Methods: Patients with iAMD received imaging with spectral-domain (SD)-OCT (Spectralis, Heidelberg Engineering) and OCT-angiography (OCT-A) (PLEX Elite 9000, ZEISS). In addition, MP examinations in photopic setting (MP-3, NIDEK) and mesopic background illumination (MAIA2, ICare) were performed. The thickness of the ellipsoid-zone (EZ) and the outer nuclear layer (ONL), as well as the volume of drusen and HRF, were segmented using deep-learning (DL)-based approaches. CC flow deficit percentage (FD%) was extracted from OCT-A slabs using a novel binarization method. Semiautomatic co-registration of MP examinations, OCT-A slabs, and OCT volumes was performed. Three exploratory models were calculated using multivariable mixed-effects models: (1) structure–function (SF) using structural OCT biomarkers, (2) flow–function (FF) utilizing OCT-A derived flow information, and (3) structure–flow–function (SFF) incorporating both OCT and OCT-A data. Model performance was evaluated using AIC and BIC criterion. Results: 19 eyes of 19 patients were evaluated, totalling 3297 MP-stimuli, 1873 B-scans, and 19 OCT-A slabs. Mean (SD) age was 76 (7) years, and sensitivity was 26.0 (3.36) dB in the MP-3 and 22.42 (3.64) dB in the MAIA2. Mesopic MAIA2 examinations showed significantly lower PWS values (−3.56 to −3.63 dB; p < 0.001). Drusen and HRF volume decreased PWS (−0.6 [95% CI: −1.04; −0.16] dB/nL; p = 0.007 and −9.56 [95% CI: −12.86; −6.26] dB/nL; p < 0.001), while ONL was positively associated with PWS (0.06 [0.05; 0.07] at an eccentricity of 5.2°; p < 0.001) in the SF model. CC FD% was not significantly associated with PWS in the FF and the SFF model (p > 0.05 in both cases). In the SFF model drusen volume (−1.69 [95% CI: −2.09; −1.29] dB/nL; p < 0.001), EZ (0.04 [95% CI: 0.02; 0.06] dB/µm; p < 0.001), and ONL thickness (0.03 [95% CI: 0.02; 0.04] dB/µm; p < 0.001) were significant predictors for PWS. The SF model exhibited the lowest AIC and BIC indicating best model performance. Conclusions: Structural parameters derived from SD-OCT such as HRF, drusen volume, and outer retinal layer thickness may be more closely associated with PWS, with CC FD% as an OCT-A-derived metric contributing limited additional explanatory benefit in cross-sectional analyses.
- 29 April 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (9) , 3392
Open AccessChoriocapillaris Flow-Enriched Prediction of Retinal Sensitivity Using OCT-Derived Biomarkers in Intermediate Age-Related Macular Degeneration
Objectives: To assess the association of structural biomarkers derived from optical coherence tomography (OCT) and choriocapillaris (CC) flow information with point-wise retinal sensitivity (PWS) measured by microperimetry (MP) in intermediate age-related macular degeneration (iAMD). Methods: Patients with iAMD received imaging with spectral-domain (SD)-OCT (Spectralis, Heidelberg Engineering) and OCT-angiography (OCT-A) (PLEX Elite 9000, ZEISS). In addition, MP examinations in photopic setting (MP-3, NIDEK) and mesopic background illumination (MAIA2, ICare) were performed. The thickness of the ellipsoid-zone (EZ) and the outer nuclear layer (ONL), as well as the volume of drusen and HRF, were segmented using deep-learning (DL)-based approaches. CC flow deficit percentage (FD%) was extracted from OCT-A slabs using a novel binarization method. Semiautomatic co-registration of MP examinations, OCT-A slabs, and OCT volumes was performed. Three exploratory models were calculated using multivariable mixed-effects models: (1) structure–function (SF) using structural OCT biomarkers, (2) flow–function (FF) utilizing OCT-A derived flow information, and (3) structure–flow–function (SFF) incorporating both OCT and OCT-A data. Model performance was evaluated using AIC and BIC criterion. Results: 19 eyes of 19 patients were evaluated, totalling 3297 MP-stimuli, 1873 B-scans, and 19 OCT-A slabs. Mean (SD) age was 76 (7) years, and sensitivity was 26.0 (3.36) dB in the MP-3 and 22.42 (3.64) dB in the MAIA2. Mesopic MAIA2 examinations showed significantly lower PWS values (−3.56 to −3.63 dB; p < 0.001). Drusen and HRF volume decreased PWS (−0.6 [95% CI: −1.04; −0.16] dB/nL; p = 0.007 and −9.56 [95% CI: −12.86; −6.26] dB/nL; p < 0.001), while ONL was positively associated with PWS (0.06 [0.05; 0.07] at an eccentricity of 5.2°; p < 0.001) in the SF model. CC FD% was not significantly associated with PWS in the FF and the SFF model (p > 0.05 in both cases). In the SFF model drusen volume (−1.69 [95% CI: −2.09; −1.29] dB/nL; p < 0.001), EZ (0.04 [95% CI: 0.02; 0.06] dB/µm; p < 0.001), and ONL thickness (0.03 [95% CI: 0.02; 0.04] dB/µm; p < 0.001) were significant predictors for PWS. The SF model exhibited the lowest AIC and BIC indicating best model performance. Conclusions: Structural parameters derived from SD-OCT such as HRF, drusen volume, and outer retinal layer thickness may be more closely associated with PWS, with CC FD% as an OCT-A-derived metric contributing limited additional explanatory benefit in cross-sectional analyses.
- Open Access
- 12 June 2025
- Published by Elsevier in Canadian Journal of Ophthalmology
- Vol. 60 (6) , e879-e887
Benchmarking test-retest variability in microperimetry for intermediate age-related macular degeneration using MP-3 and MAIA
- 12 June 2025
- Published by Elsevier in Canadian Journal of Ophthalmology
- Vol. 60 (6) , e879-e887
Open AccessBenchmarking test-retest variability in microperimetry for intermediate age-related macular degeneration using MP-3 and MAIA
- Open Access
- 10 June 2025
- Published by Elsevier in Ophthalmology Science
- Vol. 5 (6) , 100850
Exploiting Microperimetry as a Functional End Point in Healthy Aging and Different Stages of Age-Related Macular Degeneration
- 10 June 2025
- Published by Elsevier in Ophthalmology Science
- Vol. 5 (6) , 100850
Open AccessExploiting Microperimetry as a Functional End Point in Healthy Aging and Different Stages of Age-Related Macular Degeneration
- Open Access
- 20 February 2025
- Published by MDPI AG in Pharmaceuticals
- Vol. 18 (3) , 284
Rethinking Clinical Trials in Age-Related Macular Degeneration: How AI-Based OCT Analysis Can Support Successful Outcomes
Age-related macular degeneration (AMD) is a leading cause of blindness in the developed world. Due to an aging population, its prevalence is expected to increase, making novel and optimized therapy options imperative. However, both late-stage forms of the disease, neovascular AMD (nAMD) and geographic atrophy (GA), exhibit considerable variability in disease progression and treatment response, complicating the evaluation of therapeutic efficacy and making it difficult to design clinical trials that are both inclusive and statistically robust. Traditional trial designs frequently rely on generalized endpoints that may not fully capture the nuanced benefits of treatment, particularly in diseases like GA, where functional improvements can be gradual or subtle. Artificial intelligence (AI) has the potential to address these issues by identifying novel, condition-specific biomarkers or endpoints, enabling precise patient stratification and improving recruitment strategies. By providing an overview of the advances and application of AI-based optical coherence tomography analysis in the context of AMD clinical trials, this review highlights the transformative potential of AI in optimizing clinical trial outcomes for patients with nAMD or GA secondary to AMD.
- 20 February 2025
- Published by MDPI AG in Pharmaceuticals
- Vol. 18 (3) , 284
Open AccessRethinking Clinical Trials in Age-Related Macular Degeneration: How AI-Based OCT Analysis Can Support Successful Outcomes
Age-related macular degeneration (AMD) is a leading cause of blindness in the developed world. Due to an aging population, its prevalence is expected to increase, making novel and optimized therapy options imperative. However, both late-stage forms of the disease, neovascular AMD (nAMD) and geographic atrophy (GA), exhibit considerable variability in disease progression and treatment response, complicating the evaluation of therapeutic efficacy and making it difficult to design clinical trials that are both inclusive and statistically robust. Traditional trial designs frequently rely on generalized endpoints that may not fully capture the nuanced benefits of treatment, particularly in diseases like GA, where functional improvements can be gradual or subtle. Artificial intelligence (AI) has the potential to address these issues by identifying novel, condition-specific biomarkers or endpoints, enabling precise patient stratification and improving recruitment strategies. By providing an overview of the advances and application of AI-based optical coherence tomography analysis in the context of AMD clinical trials, this review highlights the transformative potential of AI in optimizing clinical trial outcomes for patients with nAMD or GA secondary to AMD.
- Open Access
- 27 December 2024
- Published by Wiley in Acta Ophthalmologica
- Vol. 103 (4) , 423-431
Normative prospective data on automatically quantified retinal morphology correlated to retinal function in healthy ageing eyes by two microperimetry devices
Purpose: The relationship between retinal morphology, as assessed by optical coherence tomography (OCT), and retinal function in microperimetry (MP) has not been well studied, despite its increasing importance as an essential functional endpoint for clinical trials and emerging therapies in retinal diseases. Normative databases of healthy ageing eyes are largely missing from literature.Methods: Healthy subjects above 50 years were examined using two MP devices, MP‐3 (NIDEK) and MAIA (iCare). An identical grid, encompassing 45 stimuli was used for retinal sensitivity (RS) assessment. Deep‐learning‐based algorithms performed automated segmentation of ellipsoid zone (EZ), outer nuclear layer (ONL), ganglion cell layer (GCL) and retinal nerve fibre layer (RNFL) from OCT volumes (Spectralis, Heidelberg). Pointwise co‐registration between each MP stimulus and corresponding location on OCT was performed via registration algorithm. Effect of age, eccentricity and layer thickness on RS was assessed by mixed effect models.Results: Three thousand six hundred stimuli from twenty eyes of twenty patients were included. Mean patient age was 68.9 ± 10.9 years. Mean RS for the first exam was 28.65 ± 2.49 dB and 25.5 ± 2.81 dB for MP‐3 and MAIA, respectively. Increased EZ thickness, ONL thickness and GCL thickness were significantly correlated with increased RS (all p < 0.001). Univariate models showed lower RS with advanced age and higher eccentricity (both p < 0.05).Conclusion: This work provides reference values for healthy age‐related EZ and ONL‐thicknesses without impairment of visual function and evidence for RS decrease with eccentricity and increasing age. This information is crucial for interpretation of future clinical trials in disease.
- 27 December 2024
- Published by Wiley in Acta Ophthalmologica
- Vol. 103 (4) , 423-431
Open AccessNormative prospective data on automatically quantified retinal morphology correlated to retinal function in healthy ageing eyes by two microperimetry devices
Purpose: The relationship between retinal morphology, as assessed by optical coherence tomography (OCT), and retinal function in microperimetry (MP) has not been well studied, despite its increasing importance as an essential functional endpoint for clinical trials and emerging therapies in retinal diseases. Normative databases of healthy ageing eyes are largely missing from literature.Methods: Healthy subjects above 50 years were examined using two MP devices, MP‐3 (NIDEK) and MAIA (iCare). An identical grid, encompassing 45 stimuli was used for retinal sensitivity (RS) assessment. Deep‐learning‐based algorithms performed automated segmentation of ellipsoid zone (EZ), outer nuclear layer (ONL), ganglion cell layer (GCL) and retinal nerve fibre layer (RNFL) from OCT volumes (Spectralis, Heidelberg). Pointwise co‐registration between each MP stimulus and corresponding location on OCT was performed via registration algorithm. Effect of age, eccentricity and layer thickness on RS was assessed by mixed effect models.Results: Three thousand six hundred stimuli from twenty eyes of twenty patients were included. Mean patient age was 68.9 ± 10.9 years. Mean RS for the first exam was 28.65 ± 2.49 dB and 25.5 ± 2.81 dB for MP‐3 and MAIA, respectively. Increased EZ thickness, ONL thickness and GCL thickness were significantly correlated with increased RS (all p < 0.001). Univariate models showed lower RS with advanced age and higher eccentricity (both p < 0.05).Conclusion: This work provides reference values for healthy age‐related EZ and ONL‐thicknesses without impairment of visual function and evidence for RS decrease with eccentricity and increasing age. This information is crucial for interpretation of future clinical trials in disease.