Anna Eidenberger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Anna Eidenberger has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Ursula Schmidt-Erfurth
Medical University of Vienna
3 shared publications - Johannes Schrittwieser
Department of Ophthalmology and Optometry Medical University of Vienna Vienna Austria
2 shared publications Markus Gumpinger
Department of Ophthalmology and Optometry Medical University of Vienna Vienna Austria
2 shared publications- Stefan Sacu
Department of Ophthalmology Medical University of Vienna Vienna Austria
2 shared publications Alexandra Miere
Department of Ophthalmology, Intercity Hospital of Créteil University Paris‐Est Créteil Créteil France
1 shared publication- Benjamin Wolff
Maison Rouge Eye Center Strasbourg France
1 shared publication
Latest Publications
- Open Access
- 29 July 2026
- Published by Wiley in Acta Ophthalmologica
Systematic quantification of outer retinal morphology in three different SD ‐ OCT devices in geographic atrophy
Purpose: To define interdevice differences in quantitative outer retinal biomarkers across three spectral‐domain (SD) optical coherence tomography (OCT) devices in geographic atrophy (GA). Methods: Patients with GA prospectively underwent imaging using Spectralis (Heidelberg Engineering), Cirrus (Zeiss) and Maestro (Topcon) OCT devices. Ellipsoid zone (EZ) and outer nuclear layer (ONL) thickness, as well as EZ and retinal pigment epithelium (RPE) loss, were automatically pre‐segmented and manually corrected. Quantitative measurements were compared between OCT devices using anova or Friedman tests. Bland–Altman analysis determined mean differences and 95% limits of agreement (LoA). Results: A total of 7080 B‐scans from 120 OCT volumes of 40 eyes were analysed. Mean patient age was 80 ± 7 years. Mean EZ thickness in the 6‐mm macular cube was 34.8 ± 4.6, 33.4 ± 4.1 and 31.0 ± 4.8 μm for Spectralis, Cirrus and Maestro, respectively, while mean ONL thickness was 77.8 ± 9.2, 78.5 ± 9.4 and 75.8 ± 9.6 μm. Interdevice differences were significant for EZ and ONL‐thickness (all p < 0.05). Mean EZ thickness bias ranged from 1.5 to 3.8 μm, with the widest LoA between Spectralis and Maestro. Mean ONL‐thickness bias ranged from −0.7 to 2.7 μm, with the widest LoA between Cirrus and Maestro. EZ‐loss and EZ/RPE‐loss‐area also differed significantly (both p < 0.01). Conclusion: Visualization and quantification of atrophic features at the level of the photoreceptors, including EZ thickness, EZ loss and ONL thickness, are influenced by the implemented OCT machine. Consistency in the OCT device during patient monitoring allows for the highest precision and eliminates interdevice differences in quantitative outcome measures.
- 29 July 2026
- Published by Wiley in Acta Ophthalmologica
Open AccessSystematic quantification of outer retinal morphology in three different SD ‐ OCT devices in geographic atrophy
Purpose: To define interdevice differences in quantitative outer retinal biomarkers across three spectral‐domain (SD) optical coherence tomography (OCT) devices in geographic atrophy (GA). Methods: Patients with GA prospectively underwent imaging using Spectralis (Heidelberg Engineering), Cirrus (Zeiss) and Maestro (Topcon) OCT devices. Ellipsoid zone (EZ) and outer nuclear layer (ONL) thickness, as well as EZ and retinal pigment epithelium (RPE) loss, were automatically pre‐segmented and manually corrected. Quantitative measurements were compared between OCT devices using anova or Friedman tests. Bland–Altman analysis determined mean differences and 95% limits of agreement (LoA). Results: A total of 7080 B‐scans from 120 OCT volumes of 40 eyes were analysed. Mean patient age was 80 ± 7 years. Mean EZ thickness in the 6‐mm macular cube was 34.8 ± 4.6, 33.4 ± 4.1 and 31.0 ± 4.8 μm for Spectralis, Cirrus and Maestro, respectively, while mean ONL thickness was 77.8 ± 9.2, 78.5 ± 9.4 and 75.8 ± 9.6 μm. Interdevice differences were significant for EZ and ONL‐thickness (all p < 0.05). Mean EZ thickness bias ranged from 1.5 to 3.8 μm, with the widest LoA between Spectralis and Maestro. Mean ONL‐thickness bias ranged from −0.7 to 2.7 μm, with the widest LoA between Cirrus and Maestro. EZ‐loss and EZ/RPE‐loss‐area also differed significantly (both p < 0.01). Conclusion: Visualization and quantification of atrophic features at the level of the photoreceptors, including EZ thickness, EZ loss and ONL thickness, are influenced by the implemented OCT machine. Consistency in the OCT device during patient monitoring allows for the highest precision and eliminates interdevice differences in quantitative outcome measures.
- Open Access
- 18 September 2025
- Published by Wiley in Acta Ophthalmologica
- Vol. 104 (3) , 305-313
Fluid/function correlation using AI ‐based quantification versus central subfield thickness in treatment‐naïve and pre‐treated patients with neovascular AMD in a real‐world setting
Purpose: To investigate the association between best‐corrected visual acuity (BCVA) and quantitative macular fluid volumes, compared to central subfield thickness (CST) in treatment‐naïve and previously treated patients with active neovascular age‐related macular degeneration (nAMD). Methods and Analysis: Baseline data were collected from 290 eyes of 290 participants consecutively enrolled in a prospective, randomized phase III clinical trial. Intraretinal fluid (IRF), subretinal fluid (SRF) and pigment epithelial detachment (PED) volumes were quantified and localized using an MDR‐certified AI algorithm (Fluid Monitor, RetInSight). Fluid volumes and CST were included in linear regression models for comparison. Results: Significantly greater IRF volumes within each macular region were observed in treatment‐naïve patients, whereas larger PED volumes contributed to higher CST values in pretreated patients. In both subgroups, the largest proportion of BCVA variance could be explained by measuring IRF and SRF volumes within the entire 6‐mm area (adjusted R 2 = 0.140 and 0.225, respectively). In pre‐treated eyes, CST explained only half as much BCVA variance as the 6‐mm fluid model, and the model's fit was even poorer when compared to the CST model in the treatment‐naïve subgroup (adjusted R 2 = 0.078 vs. 0.198). Conclusion: The examination of IRF and SRF volumes significantly impacts BCVA in nAMD. The weaker association of CST highlights its limitations as a parameter of disease activity. These findings emphasize the necessity of distinct fluid volume quantification as a relevant surrogate for visual function loss or benefit in nAMD, with particular emphasis on treatment duration and fluid in regions beyond the central 1‐mm.
- 18 September 2025
- Published by Wiley in Acta Ophthalmologica
- Vol. 104 (3) , 305-313
Open AccessFluid/function correlation using AI ‐based quantification versus central subfield thickness in treatment‐naïve and pre‐treated patients with neovascular AMD in a real‐world setting
Purpose: To investigate the association between best‐corrected visual acuity (BCVA) and quantitative macular fluid volumes, compared to central subfield thickness (CST) in treatment‐naïve and previously treated patients with active neovascular age‐related macular degeneration (nAMD). Methods and Analysis: Baseline data were collected from 290 eyes of 290 participants consecutively enrolled in a prospective, randomized phase III clinical trial. Intraretinal fluid (IRF), subretinal fluid (SRF) and pigment epithelial detachment (PED) volumes were quantified and localized using an MDR‐certified AI algorithm (Fluid Monitor, RetInSight). Fluid volumes and CST were included in linear regression models for comparison. Results: Significantly greater IRF volumes within each macular region were observed in treatment‐naïve patients, whereas larger PED volumes contributed to higher CST values in pretreated patients. In both subgroups, the largest proportion of BCVA variance could be explained by measuring IRF and SRF volumes within the entire 6‐mm area (adjusted R 2 = 0.140 and 0.225, respectively). In pre‐treated eyes, CST explained only half as much BCVA variance as the 6‐mm fluid model, and the model's fit was even poorer when compared to the CST model in the treatment‐naïve subgroup (adjusted R 2 = 0.078 vs. 0.198). Conclusion: The examination of IRF and SRF volumes significantly impacts BCVA in nAMD. The weaker association of CST highlights its limitations as a parameter of disease activity. These findings emphasize the necessity of distinct fluid volume quantification as a relevant surrogate for visual function loss or benefit in nAMD, with particular emphasis on treatment duration and fluid in regions beyond the central 1‐mm.
- Open Access
- 20 February 2025
- Published by MDPI AG in Pharmaceuticals
- Vol. 18 (3) , 284
Rethinking Clinical Trials in Age-Related Macular Degeneration: How AI-Based OCT Analysis Can Support Successful Outcomes
Age-related macular degeneration (AMD) is a leading cause of blindness in the developed world. Due to an aging population, its prevalence is expected to increase, making novel and optimized therapy options imperative. However, both late-stage forms of the disease, neovascular AMD (nAMD) and geographic atrophy (GA), exhibit considerable variability in disease progression and treatment response, complicating the evaluation of therapeutic efficacy and making it difficult to design clinical trials that are both inclusive and statistically robust. Traditional trial designs frequently rely on generalized endpoints that may not fully capture the nuanced benefits of treatment, particularly in diseases like GA, where functional improvements can be gradual or subtle. Artificial intelligence (AI) has the potential to address these issues by identifying novel, condition-specific biomarkers or endpoints, enabling precise patient stratification and improving recruitment strategies. By providing an overview of the advances and application of AI-based optical coherence tomography analysis in the context of AMD clinical trials, this review highlights the transformative potential of AI in optimizing clinical trial outcomes for patients with nAMD or GA secondary to AMD.
- 20 February 2025
- Published by MDPI AG in Pharmaceuticals
- Vol. 18 (3) , 284
Open AccessRethinking Clinical Trials in Age-Related Macular Degeneration: How AI-Based OCT Analysis Can Support Successful Outcomes
Age-related macular degeneration (AMD) is a leading cause of blindness in the developed world. Due to an aging population, its prevalence is expected to increase, making novel and optimized therapy options imperative. However, both late-stage forms of the disease, neovascular AMD (nAMD) and geographic atrophy (GA), exhibit considerable variability in disease progression and treatment response, complicating the evaluation of therapeutic efficacy and making it difficult to design clinical trials that are both inclusive and statistically robust. Traditional trial designs frequently rely on generalized endpoints that may not fully capture the nuanced benefits of treatment, particularly in diseases like GA, where functional improvements can be gradual or subtle. Artificial intelligence (AI) has the potential to address these issues by identifying novel, condition-specific biomarkers or endpoints, enabling precise patient stratification and improving recruitment strategies. By providing an overview of the advances and application of AI-based optical coherence tomography analysis in the context of AMD clinical trials, this review highlights the transformative potential of AI in optimizing clinical trial outcomes for patients with nAMD or GA secondary to AMD.