PMPaolo Liberato Magliano

Paolo Liberato Magliano

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Paolo Liberato Magliano has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Implantation Success, Electrical Performance, and Safety of an Active Fixation Stylet‐Driven Lead for LBBAP in Clinical Practice: A Multicenter Experience

    by Amato Santoro, Matteo Ziacchi, Raimondo Calvanese, Antonio Rapacciuolo, Mario Volpicelli, Luca Poggio, Pasquale Nocerino, Davide Castagno, Valter Bianchi, Paolo Liberato Magliano, et al.

    Background: Left bundle branch area pacing (LBBAP) has emerged as a promising physiological pacing strategy. However, its feasibility and safety using conventional stylet‐driven leads (SDL) such as INGEVITY+ remain under investigation. Objective: To evaluate the clinical performance, safety, and follow‐up outcomes of LBBAP using the INGEVITY+ lead in a real‐world electrophysiology setting. Methods: From 2021 to 2024, 207 consecutive patients underwent LBBAP implant attempts using the INGEVITY+ lead across 19 centers. Of these, 146 had bradycardia indications, and 61 had heart failure indications. A control group of 200 patients received standard right ventricular (RV) pacing with the same lead. Procedural outcomes, electrical parameters, complications, and mid‐term lead performance were assessed. Results: LBBAP was successfully achieved in 201 (97%) cases. Procedural and fluoroscopy times were slightly longer for LBBAP than for RV pacing. Acute complications included one helix fracture, one atrioventricular block, and one septal perforation. During a median follow‐up of 9 months, no lead fractures were reported; lead dislodgment occurred in three cases. Kaplan–Meier analysis showed no significant difference in time to first lead‐related complication between the LBBAP and RV pacing groups (hazard ratio: 4.69, 95%CI: 0.63–34.90, p = 0.139). Electrical performance remained stable, with 98% of retained leads maintaining capture thresholds ≤ 2 V and 92% with sensed amplitudes ≥ 5 mV. Conclusions: LBBAP using the INGEVITY + SDL is feasible and safe in clinical practice, with excellent implant success and stable mid‐term electrical performance. These findings support its use as a viable conduction system pacing strategy.


  • Open Access

    Implantation Success, Electrical Performance, and Safety of an active fixation stylet-driven lead for LBBAP in Clinical Practice: A Multicenter Experience

    by Amato Santoro, Matteo Ziacchi, Raimondo Calvanese, Antonio Rapacciuolo, Mario Volpicelli, Luca Poggio, Pasquale Nocerino, Davide Castagno, Valter Bianchi, Paolo Liberato Magliano, et al.

    Background: Left bundle branch area pacing (LBBAP) has emerged as a promising physiological pacing strategy. However, its feasibility and safety using conventional stylet-driven leads (SDL) such as INGEVITY+ remain under investigation. Objective: To evaluate the clinical performance, safety, and follow-up outcomes of LBBAP using the INGEVITY+ lead in a real-world electrophysiology setting. Methods: From 2021 to 2024, 207 consecutive patients underwent LBBAP implant attempts using the INGEVITY+ lead across 19 centers. Of these, 146 had bradycardia indications, and 61 had heart failure indications. A control group of 200 patients received standard right ventricular (RV) pacing with the same lead. Procedural outcomes, electrical parameters, complications, and mid-term lead performance were assessed. Results: LBBAP was successfully achieved in 201 (97%) cases. Procedural and fluoroscopy times were slightly longer for LBBAP than for RV pacing. Acute complications included one helix fracture, one atrioventricular block, and one septal perforation. During a median follow-up of 9 months, no lead fractures were reported; lead dislodgment occurred in 3 cases. Kaplan–Meier analysis showed no significant difference in time to first lead-related complication between the LBBAP and RV pacing groups (hazard ratio: 4.69, 95%CI: 0.63–34.90, p=0.139). Electrical performance remained stable, with 98% of retained leads maintaining capture thresholds ≤2 V and 92% with sensed amplitudes ≥5 mV. Conclusions : LBBAP using the INGEVITY+ SDL is feasible and safe in clinical practice, with excellent implant success and stable mid-term electrical performance. These findings support its use as a viable conduction system pacing strategy.

  • Managing a Mental Disorder With New Technologies: TheLeadless Pacemaker in Reel's Syndrome, a Case Report

    by P. L. Magliano, F. Scotto Di Uccio, R. Persico, C. Provvisiero, P. Ricciardi, V. Ducceschi

    Reel's syndrome (RS) is an unusual cause of pacemaker lead dislodgement. We present the case of a 59‐year‐old female patient with Down syndrome (DS) implanted with a dual‐chamber endovascular pacemaker due to symptomatic sinus node disfunction, reporting several syncopal episodes in last days and showing abnormal electrical parameters at the 2‐months follow‐up due to RS. The malfunctioning device was removed and an endocardial leadless pacing system was implanted.