VSVitalii Stepanenko

Vitalii Stepanenko

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Vitalii Stepanenko has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Calculation of the Fire Resistance Limit of a Steel-Reinforced Concrete Slab Based on Experimental Data on Heating in a Small-Size Fire Furnace

    by Oleksandr Nuianzin, Vitalii Stepanenko, Yaroslav Podolianets, Oleksandr Ivanenko, Francesca Fumian

    The article considers the issue of calculating the fire resistance limit of a steel-reinforced concrete slab with a corrugated profile based on experimental data of its heating in a small-sized fire furnace. The need to combine the results of experimental studies with calculation methods to increase the accuracy of determining the load-bearing capacity of structures under fire conditions is substantiated.An experimental-calculation approach is proposed, which involves the use of point temperature measurements in the control zones of the slab cross-section with subsequent interpolation of the temperature field and determination of the stress-strain state taking into account the temperature dependence of the physical and mechanical characteristics of materials. The calculation was performed in accordance with the requirements of current regulatory documents on the design of steel-reinforced concrete structures for fire resistance.An example of the application of the methodology for assessing the loss of bearing capacity of a slab under standard fire exposure and operational load conditions is given. A comparative analysis of the obtained results with experimental test data was carried out, which confirmed the adequacy and practical suitability of the proposed approach.The developed methodology allows for a substantiated determination of the fire resistance limit of steel-reinforced concrete slabs without conducting full-scale tests and can be used in the design and assessment of fire safety of building structures for various purposes.

  • Open Access

    DEPENDENCE OF THE INFLUENCE OF PARAMETRIC FIRE ON THE TEMPERATURE DISTRIBUTION ACROSS A STEEL BEAM

    by Станіслав Сідней, Ірина Рудешко, Іван Іщенко, Євгеній Школяр, Roman Motrichuk, Віталій Степаненко, Stanislav Sidnei, Iryna Rudeshko, Ivan Ishchenko, Ievgenii Shkoliar

    The article investigates the impact of a parametric fire on the temperature distribution in a steel beam, which is a critical factor in assessing its fire resistance. Numerical modeling of thermal processes was conducted using the Transient Thermal computational module in ANSYS WB, employing the finite element method. In solving the heat transfer problem, the properties of steel were adopted in accordance with the recommendations of Eurocode 3. The boundary conditions were applied based on a three-sided heating scenario, taking into account convective and radiative heat transfer. This approach enabled the determination of temperature fields in the beam under various fire exposure scenarios. A comparative analysis of the structural behavior under both standard and parametric fire conditions revealed significant differences in the heating dynamics. The study showed that the maximum temperature in the standard fire scenario reaches 943.09°C, which is 18.3% higher than the corresponding value for the parametric fire (770°C). This indicates that under the standard fire regime, the beam undergoes more intense heating, potentially leading to a faster loss of load-bearing capacity. Based on the obtained results, a polynomial dependency for temperature variations in the steel beam was formulated, demonstrating a high level of accuracy (R² = 0.9978) compared to the calculated data. These dependencies can be utilized to enhance methods for assessing the fire resistance of steel structures and for calculating their thermal state under fire conditions. The findings of this study are particularly relevant for the development of modern regulatory guidelines and the improvement of design strategies for steel structures, considering the impact of parametric fires. This research highlights the importance of accounting for realistic fire scenarios in structural fire engineering to ensure more accurate predictions of thermal performance and fire resistance of load-bearing steel elements in building design.

  • Modeling the Thermal Effects of Fire on Steel-Reinforced Concrete Slabs with a Corrugated Profile

    by Svitlana Fedchenko, Oleksandr Nuianzin, Vitalii Stepanenko, Serhii Vedula

    The aim of the work was to determine the possibility of not taking into account the orientation (vertical or horizontal) of the studied elements of steel-reinforced concrete slabs with a corrugated profile during their heating in a modular small-sized fire furnace. The work investigated the temperature distributions on the outer surface of the corrugated ceiling profile of a steel-reinforced concrete slab of horizontal orientation simulated in the fire furnace chamber. To create geometric models of the fire furnace chamber and the studied element, a CAD software complex was used. To solve the heat engineering problem, mathematical (numerical) methods were used, based on solving systems of differential equations of continuous media such as the Navier-Stokes equation and the Fourier heat conductivity equation. According to the results obtained, the temperature distribution on the outer surface of the steel profile of the reinforced concrete slab is uniform, the temperature deviation in different places on the surface does not exceed 7 %. The maximum temperature on the heating surface of the steel profile of the reinforced concrete slab in the last minute of computer simulation reached 921 °С and the average temperature at this time over the entire surface of the structure was 917 °С. To determine the appropriate orientation of the test sample during fire tests, a comparison of the obtained temperature distributions on the outer surface of the corrugated profile of a horizontally placed reinforced concrete slab with the temperature distributions on the outer surface of the corrugated profile of a vertically placed reinforced concrete slab, which were given in the previous work was made. Analysis of the average surface temperatures of the corrugated profile of a reinforced concrete slab of horizontal and vertical orientation showed that the temperature distribution over the surface of the profile was uniform in both cases and the results obtained show good reproducibility of the experiment during computer simulation. And the orientation of the tested elements does not affect the temperature distribution over the outer surface of the corrugated profile of a reinforced concrete slab in the simulated furnace.


  • Open Access

    Substantiating the parametric temperature mode during a fire on transformers placed inside protective structures

    by Roman Palchykov, Yaroslav Ballo, Vadym Nizhnyk, Viktor Mykhailov, Andrii Gavryliuk, Vasyl Loik, Oleksandr Synelnikov, Serhii Synelnikov, Vitalii Stepanenko, Oleksandr Nuianzin

    The object of this study was the change in temperature during a fire on transformers located in protective structures. Investigating the change in temperature during a fire on transformers located in protective structures is one of the priority tasks for protecting the economy and national security of the country. The studies solved the problem of fire resistance of the enclosing structures of protective structures in which the transformer is located. The fire resistance of enclosing structures has been confirmed by meeting the conditions related, in particular, to the calculated value of the critical temperature of the material. The selection of the calculation scenario for investigating the temperature regime during a fire on a transformer located in a protective structure was carried out according to two scenarios of the occurrence and spread of fires. The study demonstrated temperature changes in the protective structure during the burning of the transformer based on data of the temperature sensor installed at heights of 1 m, 10 m, and 18 m above the place of occurrence of combustion. Certain conditions were taken into account for the calculation scenarios of the spread of fire and changes in the temperature effect on building structures. Cases when an automatic water fire extinguishing system is functioning and not functioning in the protective structure were taken into account. In order to substantiate the temperature regime during a transformer fire, the conditions of the greatest impact of temperature on building structures were adopted. The following conditions were accepted: there is no automatic fire extinguishing system in the protective room; temperature sensor readings were located at a level of 18 m from the floor level of the protective structure. The calculation of the temperature regime during a transformer fire, which is located in the protective structure, was carried out using a field model, employing the reaction of simple stoichiometry (transformer oil can contain only carbon, hydrogen, oxygen, and nitrogen atoms). Based on the results of this study, a modified temperature regime during a fire on transformers located in protective structures was substantiated. The maximum temperature range for a developed fire was from 900 °C to 1100 °C. A standardized time (up to 30 minutes) has also been established during which the building structures of protective structures must withstand the effects of the modified temperature regime


  • Open Access

    ДОСЛІДЖЕННЯ ВПЛИВУ КОНФІГУРАЦІЇ МАЛОГАБАРИТНОЇ ВОГНЕВОЇ УСТАНОВКИ НА РІВНОМІРНІСТЬ НАГРІВАННЯ ПОВЕРХНІ СТАЛЕЗАЛІЗОБЕТОННОЇ ПЛИТИ

    by Віталій Степаненко

    Метою роботи була перевірка можливості змоделювати тепломасоперенос усередині камери вогневої печі та аналіз якості роботи комп’ютерної моделі під час нагрівання сталезалізобетонних плит з гофрованим профілем. Проведено порівняння результатів з експериментальними даними. Для створення геометричних моделей використано CAD-програмний комплекс. Далі 3-D модель імпортовано у програмний комплекс CFD. Для відтворення процесу тепломасообміну у вогневій печі застосовані математичні методи, засновані на використанні системи диференціальних рівнянь на основі неперервних середовищ типу Нав’є-Стокса, рівнянь теплопровідності в умовах нагрівання під час пожежі та рівняння теплопровідності Фур’є. У комп’ютерній моделі камери вогневої печі створено розрахункову сітку. Розмір комірок визначено згідно з принципом розумної достатності. Відповідно до отриманих результатів зовнішня поверхня гофрованого сталевого профілю сталезалізобетонної конструкції прогрівалась відносно рівномірно. Вища температура спостерігалась у рівних частинах, нижча – на згинах. Максимальною була температура на обігрівній поверхні несучої стіни на останній хвилині моделювання і досягала 840 ºС, а середня температура в цей момент часу по усій поверхні конструкції становила 820 ºС. Розподіл температур по поверхні конструкції є рівномірним, відхилення у різних місцях поверхні не перевищує 5%. Здійснено порівняння температурних режимів у камері печі під час експериментальних досліджень та моделювання. Результати засвідчили достатньо високу їх відтворюваність.

  • Results of the heating of reinforced concrete slabs with a corrugated profile during the thermal effect of fire

    by Vitalii Stepanenko, Oleksandr Nuianzin, Alina Perehin, Dmitro Kryshtal, Dmitro Kopytin

    Three experiments were conducted on heating fragments of reinforced concrete slabs with a corrugated profile in a small-sized installation and the results of the thermal effect of fire at control points were analyzed for the possibility of their use when assessing the fire resistance of the specified building structures. The methodology and results of experiments on heating frag-ments of reinforced concrete slabs with a corrugated profile and the study of the temperature on heated and unheated surfaces, in the reinforcement layer and at control points were substantiated. Conducting the above-mentioned experiments in a small-sized installation for the study of the thermal effect of fire on building structures without mechanical load consisted in the effect of the standard temperature regime of fire with one-sided heating. To measure the temperature in the furnace and in the investigated fragments, thermocouples were used, which can be used to measure temperatures in the range from 0 to 1300 ℃ and thermistors to measure temperatures in the range from -30 to 300 ℃. According to the conducted experiment, there was a uniform distribution of temperatures on the heating surface of the studied small fragment, the maximum temperature reached was 760 ℃. Maximum temperatures: at control points it was 145 ̊℃; on the unheated surface it was 45 ℃, and at the level of the armature – 350 ℃. Studies are limited to 60 minutes, since the temperature can then approach the stationary one. The adequacy of the experimental data was confirmed: the relative deviation did not exceed 4.1 %, and the calculated adequacy criteria (Fisher, Student and Cochrane) were below the critical value. The initial data of the experimental study can serve as the basis for reproducing the temperature field inside the slab.


  • Open Access

    STUDY OF FIRE TEMPERATURE MODES IN HORIZONTAL CABLE TUNNELS DEPENDING ON PARAMETERS AND FIRE LOAD

    by Cherkassy Institute of Fire Safety Named after Chernobyl Heroes ofNational University of Civil Defense of Ukraine, Oleksandr Nuianzin, Oleksandr Ivanenko, Vitalii Stepanenko, Taras Samchenko, Олександр Іваненко

    Based on the results of the work, the dependences describing the maximum temperature inside the cable tunnel during a fire, the duration of a fire in a certain local area of the cable tunnel, and the time to reach the maximum temperature inside the cable tunnel during a fire were obtained from the fire load, the cross-sectional area ofthe tunnel, and the speed of movement of air masses inside.In one of the CFD software complexes, a mathematical model of the cable tunnel, similar to the real one, was created. A computational experiment was conducted. Modeling, as a method of scientific research, makes it possible to conduct all the necessary experiments on determining the temperature regimes of fire in cable tunnels without performing materially expensive and time-consuming field experiments on models.Based on the results of the computationalexperiment and field tests, adequacy criteria were calculated (Student's t-test, Cochran's Q-test, Fisher's F-criterion). Based on the analysis, the adequacy of the used mathematical models was investigated.A full factorial experiment was designed and conducted. According to its results, regressions of the maximum temperature inside the cable tunnel during a fire, the duration of a fire in a certain local area of the cable tunnel, and the time of reaching the maximum temperature inside the cable tunnel during a fire were obtained.The temperature regime of the fire in cable tunnels with different sizes, aerodynamic parameters and fire load was determined, as well as the dependence on the specified parameters of the temperature regime of the fire.


  • Open Access

    RESEARCH ON THE INFLUENCE OF THE FINITE ELEMENT MESH ON THE TEMPERATURE DISTRIBUTION OVER THE RIBBED PLATE IN FIRE MODELING

    by Cherkasy Institute of Fire Safety named after Сhernobyl HeroesNational University of Civil Protection of Ukraine, Stanislav Sidnei, Iryna Rudeshko, Ivan Ishchenko, Oleksandr Ivanenko, Vitalii Stepanenko, Станіслав Сідней, Ірина Рудешко, Іван Іщенко, Олександр Іваненко

    The article investigates the influence of finite element mesh type on the temperature distribution in reinforced concrete ribbed slabs during fire modeling. The thermal task was solved using three mesh generation methods: Automatic, MultiZone, and Body Sizing. The results revealed significant differences in the accuracy of temperature modeling depending on the mesh type. The Body Sizing method demonstrated the most physically accurate temperature distribution in concrete and reinforcement, closely aligning with the standard fire temperature regime. Unlike the other methods, it avoided non-physical negative temperature values in the reinforcement, which were observed with Automatic and MultiZone meshes.Key findings indicate that mesh optimization is critical for improving the reliability of thermal modeling results. A correct temperature distribution model ensures a more accurate representation of material properties, particularly their mechanical behavior under fire conditions. For instance, the maximum concrete temperature observed with the Body Sizing method was 944.26 °C, which is consistent with the standard temperature regime, compared to 967.96 °C and 956.15 °C for the Automatic and MultiZone methods, respectively. Similarly, reinforcement temperatures followed the same trend: 887.49 °C for Body Sizing versus 936.52 °C for Automatic and 897.44 °C for MultiZone.The study emphasizes the importance of selecting an optimal finite element model to evaluate fire resistance accurately. This research contributes to improving fire safety assessments by enabling more precise predictions of the thermal behavior of reinforced concrete structures. Such findings are essential for designing safe and efficient structural systems, ensuring compliance with fire resistance standards, and enhancing the performance of building components under fire exposure.The results are valuable for professionals involved in structural design and fire safety engineering, offering a foundation for developing advanced modeling techniques to predict and improve the fire resistance of ribbed slabs and similar constructions.