Ivan Ishchenko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ivan Ishchenko has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Stanislav Sidnei
National University of Civil Protection of Ukraine
5 shared publications Іван Іщенко
5 shared publications- Roman Motrichuk
National University of Civil Protection of Ukraine
4 shared publications Станіслав Сідней
4 shared publications- Andriy Berezovskyi
Національний університет цивільного захисту України
3 shared publications Iryna Rudeshko
National University of Civil Protection of Ukraine
3 shared publications
Latest Publications
- Open Access
- 23 December 2025
- Published by Lviv State University of Life Safety in Fire Safety
- Vol. 47, 61-69
ПЕРЕВАГИ І НЕДОЛІКИ ПОРОШКОВИХ ЗАСОБІВ ГАСІННЯ ПОЖЕЖІ ТА ШЛЯХИ ВДОСКОНАЛЕННЯ ЦИХ ЗАСОБІВ
Проблема. Порошкові засоби гасіння пожеж, незважаючи на їхню високу ефективність та екологічну безпеку, мають низку обмежень, що ускладнюють їх застосування в умовах технологічних процесів і на об’єктах з підвищеним рівнем техногенної небезпеки. Серед основних недоліків – короткочасна дія, утворення щільної хмари пилу, що різко погіршує видимість, схильність до комкування під час зберігання, а також низька ефективність у разі гасіння розливів горючих рідин на великій площі (особливо на поверхні водойм), оскільки порошок не створює стійкого ізолюючого шару й не запобігає повторному займанню. Мета – обґрунтування шляхів удосконалення вогнегасних порошкових засобів шляхом іммобілізації вогнегасних солей на високопористих носіях (мінеральних і рослинних), що дає можливість усунути їх ключові експлуатаційні недоліки та розширити сферу застосування, зокрема для гасіння пожеж горючих рідин на поверхні водойм та для попередження поширення пожеж на торфовищах. Методи дослідження. У роботі використано порівняльний аналіз механізмів дії порошкових засобів, впливу дисперсності на вогнегасну ефективність порошкових сумішей, а також експертну оцінку технологічних обмежень при виготовленні та зберіганні. Запропоновано інженерні рішення на основі іммобілізації вогнегасних солей на природних носіях. Основні результати дослідження. Встановлено, що порошки мікронного розміру мають високу гасильну здатність, але є нестабільними під час зберігання. Як альтернативний підхід, що вирішує проблеми зберігання та комкування традиційних ВГП, розглядаються системи аерозольного пожежогасіння. У них вогнегасна речовина – дрібнодисперсний аерозоль – генерується безпосередньо в захищеному приміщенні під час спрацювання генератора вогнегасного аерозолю. Розроблено метод іммобілізації активних компонентів на внутрішній поверхні капілярів високопористих мінералів або деревної тирси, що дає змогу стабілізувати властивості порошку та розширити сферу його застосування. Висновки та конкретні пропозиції автора. Порошкові засоби гасіння можуть бути ефективно адаптовані до використання на складних об’єктах, зокрема для гасіння пожеж на водній поверхні та торфовищах, за умови вдосконалення їх фізико-хімічних характеристик. У статті пропонується впровадження технології іммобілізації вогнегасних солей на природних носіях як перспективний напрям для підвищення стабільності та функціональності порошкових рецептур.
- 23 December 2025
- Published by Lviv State University of Life Safety in Fire Safety
- Vol. 47, 61-69
Open AccessПЕРЕВАГИ І НЕДОЛІКИ ПОРОШКОВИХ ЗАСОБІВ ГАСІННЯ ПОЖЕЖІ ТА ШЛЯХИ ВДОСКОНАЛЕННЯ ЦИХ ЗАСОБІВ
Проблема. Порошкові засоби гасіння пожеж, незважаючи на їхню високу ефективність та екологічну безпеку, мають низку обмежень, що ускладнюють їх застосування в умовах технологічних процесів і на об’єктах з підвищеним рівнем техногенної небезпеки. Серед основних недоліків – короткочасна дія, утворення щільної хмари пилу, що різко погіршує видимість, схильність до комкування під час зберігання, а також низька ефективність у разі гасіння розливів горючих рідин на великій площі (особливо на поверхні водойм), оскільки порошок не створює стійкого ізолюючого шару й не запобігає повторному займанню. Мета – обґрунтування шляхів удосконалення вогнегасних порошкових засобів шляхом іммобілізації вогнегасних солей на високопористих носіях (мінеральних і рослинних), що дає можливість усунути їх ключові експлуатаційні недоліки та розширити сферу застосування, зокрема для гасіння пожеж горючих рідин на поверхні водойм та для попередження поширення пожеж на торфовищах. Методи дослідження. У роботі використано порівняльний аналіз механізмів дії порошкових засобів, впливу дисперсності на вогнегасну ефективність порошкових сумішей, а також експертну оцінку технологічних обмежень при виготовленні та зберіганні. Запропоновано інженерні рішення на основі іммобілізації вогнегасних солей на природних носіях. Основні результати дослідження. Встановлено, що порошки мікронного розміру мають високу гасильну здатність, але є нестабільними під час зберігання. Як альтернативний підхід, що вирішує проблеми зберігання та комкування традиційних ВГП, розглядаються системи аерозольного пожежогасіння. У них вогнегасна речовина – дрібнодисперсний аерозоль – генерується безпосередньо в захищеному приміщенні під час спрацювання генератора вогнегасного аерозолю. Розроблено метод іммобілізації активних компонентів на внутрішній поверхні капілярів високопористих мінералів або деревної тирси, що дає змогу стабілізувати властивості порошку та розширити сферу його застосування. Висновки та конкретні пропозиції автора. Порошкові засоби гасіння можуть бути ефективно адаптовані до використання на складних об’єктах, зокрема для гасіння пожеж на водній поверхні та торфовищах, за умови вдосконалення їх фізико-хімічних характеристик. У статті пропонується впровадження технології іммобілізації вогнегасних солей на природних носіях як перспективний напрям для підвищення стабільності та функціональності порошкових рецептур.
- Open Access
- 11 December 2025
- Published by National University of Civil Protection of Ukraine in Scientific bulletin: Сivil protection and fire safety
- No. 2(20),p. 40-46
DEPENDENCE OF THE INFLUENCE OF PARAMETRIC FIRE ON THE TEMPERATURE DISTRIBUTION ACROSS A STEEL BEAM
The article investigates the impact of a parametric fire on the temperature distribution in a steel beam, which is a critical factor in assessing its fire resistance. Numerical modeling of thermal processes was conducted using the Transient Thermal computational module in ANSYS WB, employing the finite element method. In solving the heat transfer problem, the properties of steel were adopted in accordance with the recommendations of Eurocode 3. The boundary conditions were applied based on a three-sided heating scenario, taking into account convective and radiative heat transfer. This approach enabled the determination of temperature fields in the beam under various fire exposure scenarios. A comparative analysis of the structural behavior under both standard and parametric fire conditions revealed significant differences in the heating dynamics. The study showed that the maximum temperature in the standard fire scenario reaches 943.09°C, which is 18.3% higher than the corresponding value for the parametric fire (770°C). This indicates that under the standard fire regime, the beam undergoes more intense heating, potentially leading to a faster loss of load-bearing capacity. Based on the obtained results, a polynomial dependency for temperature variations in the steel beam was formulated, demonstrating a high level of accuracy (R² = 0.9978) compared to the calculated data. These dependencies can be utilized to enhance methods for assessing the fire resistance of steel structures and for calculating their thermal state under fire conditions. The findings of this study are particularly relevant for the development of modern regulatory guidelines and the improvement of design strategies for steel structures, considering the impact of parametric fires. This research highlights the importance of accounting for realistic fire scenarios in structural fire engineering to ensure more accurate predictions of thermal performance and fire resistance of load-bearing steel elements in building design.
- 11 December 2025
- Published by National University of Civil Protection of Ukraine in Scientific bulletin: Сivil protection and fire safety
- No. 2(20),p. 40-46
Open AccessDEPENDENCE OF THE INFLUENCE OF PARAMETRIC FIRE ON THE TEMPERATURE DISTRIBUTION ACROSS A STEEL BEAM
The article investigates the impact of a parametric fire on the temperature distribution in a steel beam, which is a critical factor in assessing its fire resistance. Numerical modeling of thermal processes was conducted using the Transient Thermal computational module in ANSYS WB, employing the finite element method. In solving the heat transfer problem, the properties of steel were adopted in accordance with the recommendations of Eurocode 3. The boundary conditions were applied based on a three-sided heating scenario, taking into account convective and radiative heat transfer. This approach enabled the determination of temperature fields in the beam under various fire exposure scenarios. A comparative analysis of the structural behavior under both standard and parametric fire conditions revealed significant differences in the heating dynamics. The study showed that the maximum temperature in the standard fire scenario reaches 943.09°C, which is 18.3% higher than the corresponding value for the parametric fire (770°C). This indicates that under the standard fire regime, the beam undergoes more intense heating, potentially leading to a faster loss of load-bearing capacity. Based on the obtained results, a polynomial dependency for temperature variations in the steel beam was formulated, demonstrating a high level of accuracy (R² = 0.9978) compared to the calculated data. These dependencies can be utilized to enhance methods for assessing the fire resistance of steel structures and for calculating their thermal state under fire conditions. The findings of this study are particularly relevant for the development of modern regulatory guidelines and the improvement of design strategies for steel structures, considering the impact of parametric fires. This research highlights the importance of accounting for realistic fire scenarios in structural fire engineering to ensure more accurate predictions of thermal performance and fire resistance of load-bearing steel elements in building design.
- 30 October 2025
- Published by National University of Civil Protection of Ukraine in Problems of Emergency Situations
- p. 264
Залежність межі вогнестійкості сталевої колони від рівня навантаження
У межах дослідження було проведено розрахунки з оцінювання вогнестійкості сталевої колони в умовах впливу пожежі з урахуванням різного рівня механічного навантаження. Математичне моделювання, виконане у програмному середовищі ANSYS, дозволило врахувати температурно-залежні характеристики матеріалу, просторову геометрію елемента та комбіновану дію температурного й механічного навантаження. Об’єктом дослідження є напружено-деформований стан сталевої колони без вогнезахисту в умовах сумісного впливу температурного та механічного навантаження. Проблема дослідження полягає в тому, що в сучасній інженерній практиці відсутній спрощений підхід до оцінювання вогнестійкості сталевих колон, який би забезпечував прийнятний рівень точності, порівнянний з результатами, отриманими за допомогою уточнених методів чисельного моделювання. Застосування таких методів потребує значних обчислювальних ресурсів, спеціалізованого програмного забезпечення та високої кваліфікації виконавців, що ускладнює їх використання під час проєктування або під час оцінювання ризиків у реальних умовах. Через це виникає необхідність у створенні більш доступного інженерного ін-струменту, який би дозволив з достатньою точністю прогнозувати втрату несучої здатності конструкцій в умовах пожежі без залучення складних розрахункових схем. Ці розрахунки стали основою для побудови аналітичної залежності межі вогнестійкості конструкції від рівня навантаження. Запропонована залежність забезпечує високу точність, порівнянну з уточненими методами, і водночас дозволяє швидко оцінювати вогнестійкість аналогічних конструкцій без потреби у складному чисельному моделюванні. Таким чином, отримані результати стали підґрунтям для формування практично орієнтованого підходу до попереднього визначення межі вогнестійкості сталевих колон при заданому рівні навантаження.
- 30 October 2025
- Published by National University of Civil Protection of Ukraine in Problems of Emergency Situations
- p. 264
Залежність межі вогнестійкості сталевої колони від рівня навантаження
У межах дослідження було проведено розрахунки з оцінювання вогнестійкості сталевої колони в умовах впливу пожежі з урахуванням різного рівня механічного навантаження. Математичне моделювання, виконане у програмному середовищі ANSYS, дозволило врахувати температурно-залежні характеристики матеріалу, просторову геометрію елемента та комбіновану дію температурного й механічного навантаження. Об’єктом дослідження є напружено-деформований стан сталевої колони без вогнезахисту в умовах сумісного впливу температурного та механічного навантаження. Проблема дослідження полягає в тому, що в сучасній інженерній практиці відсутній спрощений підхід до оцінювання вогнестійкості сталевих колон, який би забезпечував прийнятний рівень точності, порівнянний з результатами, отриманими за допомогою уточнених методів чисельного моделювання. Застосування таких методів потребує значних обчислювальних ресурсів, спеціалізованого програмного забезпечення та високої кваліфікації виконавців, що ускладнює їх використання під час проєктування або під час оцінювання ризиків у реальних умовах. Через це виникає необхідність у створенні більш доступного інженерного ін-струменту, який би дозволив з достатньою точністю прогнозувати втрату несучої здатності конструкцій в умовах пожежі без залучення складних розрахункових схем. Ці розрахунки стали основою для побудови аналітичної залежності межі вогнестійкості конструкції від рівня навантаження. Запропонована залежність забезпечує високу точність, порівнянну з уточненими методами, і водночас дозволяє швидко оцінювати вогнестійкість аналогічних конструкцій без потреби у складному чисельному моделюванні. Таким чином, отримані результати стали підґрунтям для формування практично орієнтованого підходу до попереднього визначення межі вогнестійкості сталевих колон при заданому рівні навантаження.
- Open Access
- 1 January 2025
- Published by National University of Civil Protection of Ukraine in Emergency Situations: Prevention and Liquidation
- Vol. 9 (1) , 184-194
SOLUTION TO THE PROBLEM OF IDENTIFYING THE DYNAMIC PARAMETERS OF A HUMAN OPERATOR OF A MOBILE FIRE-FIGHTING UNIT BASED ON SEGWAY WHILE EXTINGUISHING FIRES
This study addresses the pressing scientific and technical challenge of enhancing the efficiency of autonomous mobile firefighting units based on Segway platforms. The research focuses on modeling the behavior of the human operator, a key component in the control system responsible for directing the extinguishing agent. The subject of the study is a Segway-based mobile firefighting unit, characterized by itshigh maneuverability, compact size, and suitability for operation in environments with complex architectural layouts.The paper emphasizes the necessity of formalizing the operator’s dynamic characteristics. A linear model of the operator is proposed, comprising three sequential elements: a delay link, a non-inertial link, and an inertial link. To identify the parameters of this model, a series of experiments was conducted in which operators responded to visual stimuli presented via an interactive whiteboard. Measurements of reaction times and control movements enabled the calculation of transfer functions and identification of time-related parameters.The experimental results revealed the following operator characteristics: delay time —0.17–0.25 seconds; time constant —0.26–0.30 seconds; transfer coefficient —2.34–2.97. Stabilization of these values was observed after 12 trials, indicating a training effect. These findings form the basis for constructing a generalized mathematical model that enhances theaccuracy, reliability, and adaptability of autonomous firefighting systems operating in real-time. The conclusions support the development of adaptive control systems incorporating human-in-the-loop dynamics.Keywords: mobile fire unit, segway, human operator, operator, dynamic modeling.
- 1 January 2025
- Published by National University of Civil Protection of Ukraine in Emergency Situations: Prevention and Liquidation
- Vol. 9 (1) , 184-194
Open AccessSOLUTION TO THE PROBLEM OF IDENTIFYING THE DYNAMIC PARAMETERS OF A HUMAN OPERATOR OF A MOBILE FIRE-FIGHTING UNIT BASED ON SEGWAY WHILE EXTINGUISHING FIRES
This study addresses the pressing scientific and technical challenge of enhancing the efficiency of autonomous mobile firefighting units based on Segway platforms. The research focuses on modeling the behavior of the human operator, a key component in the control system responsible for directing the extinguishing agent. The subject of the study is a Segway-based mobile firefighting unit, characterized by itshigh maneuverability, compact size, and suitability for operation in environments with complex architectural layouts.The paper emphasizes the necessity of formalizing the operator’s dynamic characteristics. A linear model of the operator is proposed, comprising three sequential elements: a delay link, a non-inertial link, and an inertial link. To identify the parameters of this model, a series of experiments was conducted in which operators responded to visual stimuli presented via an interactive whiteboard. Measurements of reaction times and control movements enabled the calculation of transfer functions and identification of time-related parameters.The experimental results revealed the following operator characteristics: delay time —0.17–0.25 seconds; time constant —0.26–0.30 seconds; transfer coefficient —2.34–2.97. Stabilization of these values was observed after 12 trials, indicating a training effect. These findings form the basis for constructing a generalized mathematical model that enhances theaccuracy, reliability, and adaptability of autonomous firefighting systems operating in real-time. The conclusions support the development of adaptive control systems incorporating human-in-the-loop dynamics.Keywords: mobile fire unit, segway, human operator, operator, dynamic modeling.
- Open Access
- 1 January 2024
- Published by National University of Civil Protection of Ukraine in Emergency Situations: Prevention and Liquidation
- Vol. 8 (1) , 91-100
RESEARCH OF THEFIRE RESISTANCE OF REINFORCED CONCRETE HOLLOW CORE SLAB
The paper presents the results of evaluating the fire resistance of a reinforced concrete hollow slab using a refined method using the finite element method. The purpose of the work is to determine which limit state of fire resistance of the considered reinforced concrete hollow slab occurs first under the influence of thestandard fire temperature regime. The creation of mathematical models of concrete and reinforcement materials was carried out taking into account the recommendations of Eurocode 2. Symmetry was used to reduce resource provision during calculations. A finite-element mesh of the studied reinforced concrete hollow slab was created using finite elements of the following types: SOLID186, CONTAL174, SURF154 and REINF264. Computational experiments were carried out in two stages, in the first stage a thermal engineering problem was solved, in the second stage a static calculation was conducted to assess the fire resistance of a reinforced concrete hollow slab. The calculations were carried out according to the specified method recommended by Eurocode 2 in the thermal and mechanical modules of the AYSYS WB software complex. In order to obtain the most reliable results of the behavior of the studied reinforced concrete hollow slab during the study of the results of the stress-strain state, hinged resting on the stand is provided.The obtained results indicate that the onset of the limit state for the loss of entiretyoccurs earlier than for the loss of bearing capacity at 678 s, which poses threats to the life and health of people before the occurrence of critical deflection due to the penetration of smoke, toxic products of combustion and temperature through the cracks formed in the structure . Loss of heat-insulating ability at the time of loss of entiretywas also not observed. According to the results of computational experiments, it was established that the fire resistance limit of the investigated reinforced concrete hollow slab is 40.83 min and does not correspond to the REI 45 fire resistance class under the condition of its load of 4 kPa
- 1 January 2024
- Published by National University of Civil Protection of Ukraine in Emergency Situations: Prevention and Liquidation
- Vol. 8 (1) , 91-100
Open AccessRESEARCH OF THEFIRE RESISTANCE OF REINFORCED CONCRETE HOLLOW CORE SLAB
The paper presents the results of evaluating the fire resistance of a reinforced concrete hollow slab using a refined method using the finite element method. The purpose of the work is to determine which limit state of fire resistance of the considered reinforced concrete hollow slab occurs first under the influence of thestandard fire temperature regime. The creation of mathematical models of concrete and reinforcement materials was carried out taking into account the recommendations of Eurocode 2. Symmetry was used to reduce resource provision during calculations. A finite-element mesh of the studied reinforced concrete hollow slab was created using finite elements of the following types: SOLID186, CONTAL174, SURF154 and REINF264. Computational experiments were carried out in two stages, in the first stage a thermal engineering problem was solved, in the second stage a static calculation was conducted to assess the fire resistance of a reinforced concrete hollow slab. The calculations were carried out according to the specified method recommended by Eurocode 2 in the thermal and mechanical modules of the AYSYS WB software complex. In order to obtain the most reliable results of the behavior of the studied reinforced concrete hollow slab during the study of the results of the stress-strain state, hinged resting on the stand is provided.The obtained results indicate that the onset of the limit state for the loss of entiretyoccurs earlier than for the loss of bearing capacity at 678 s, which poses threats to the life and health of people before the occurrence of critical deflection due to the penetration of smoke, toxic products of combustion and temperature through the cracks formed in the structure . Loss of heat-insulating ability at the time of loss of entiretywas also not observed. According to the results of computational experiments, it was established that the fire resistance limit of the investigated reinforced concrete hollow slab is 40.83 min and does not correspond to the REI 45 fire resistance class under the condition of its load of 4 kPa
- Open Access
- 1 January 2024
- Published by National University of Civil Protection of Ukraine in Emergency Situations: Prevention and Liquidation
- Vol. 8 (2) , 121-132
RESEARCH ON THE INFLUENCE OF THE FINITE ELEMENT MESH ON THE TEMPERATURE DISTRIBUTION OVER THE RIBBED PLATE IN FIRE MODELING
The article investigates the influence of finite element mesh type on the temperature distribution in reinforced concrete ribbed slabs during fire modeling. The thermal task was solved using three mesh generation methods: Automatic, MultiZone, and Body Sizing. The results revealed significant differences in the accuracy of temperature modeling depending on the mesh type. The Body Sizing method demonstrated the most physically accurate temperature distribution in concrete and reinforcement, closely aligning with the standard fire temperature regime. Unlike the other methods, it avoided non-physical negative temperature values in the reinforcement, which were observed with Automatic and MultiZone meshes.Key findings indicate that mesh optimization is critical for improving the reliability of thermal modeling results. A correct temperature distribution model ensures a more accurate representation of material properties, particularly their mechanical behavior under fire conditions. For instance, the maximum concrete temperature observed with the Body Sizing method was 944.26 °C, which is consistent with the standard temperature regime, compared to 967.96 °C and 956.15 °C for the Automatic and MultiZone methods, respectively. Similarly, reinforcement temperatures followed the same trend: 887.49 °C for Body Sizing versus 936.52 °C for Automatic and 897.44 °C for MultiZone.The study emphasizes the importance of selecting an optimal finite element model to evaluate fire resistance accurately. This research contributes to improving fire safety assessments by enabling more precise predictions of the thermal behavior of reinforced concrete structures. Such findings are essential for designing safe and efficient structural systems, ensuring compliance with fire resistance standards, and enhancing the performance of building components under fire exposure.The results are valuable for professionals involved in structural design and fire safety engineering, offering a foundation for developing advanced modeling techniques to predict and improve the fire resistance of ribbed slabs and similar constructions.
- 1 January 2024
- Published by National University of Civil Protection of Ukraine in Emergency Situations: Prevention and Liquidation
- Vol. 8 (2) , 121-132
Open AccessRESEARCH ON THE INFLUENCE OF THE FINITE ELEMENT MESH ON THE TEMPERATURE DISTRIBUTION OVER THE RIBBED PLATE IN FIRE MODELING
The article investigates the influence of finite element mesh type on the temperature distribution in reinforced concrete ribbed slabs during fire modeling. The thermal task was solved using three mesh generation methods: Automatic, MultiZone, and Body Sizing. The results revealed significant differences in the accuracy of temperature modeling depending on the mesh type. The Body Sizing method demonstrated the most physically accurate temperature distribution in concrete and reinforcement, closely aligning with the standard fire temperature regime. Unlike the other methods, it avoided non-physical negative temperature values in the reinforcement, which were observed with Automatic and MultiZone meshes.Key findings indicate that mesh optimization is critical for improving the reliability of thermal modeling results. A correct temperature distribution model ensures a more accurate representation of material properties, particularly their mechanical behavior under fire conditions. For instance, the maximum concrete temperature observed with the Body Sizing method was 944.26 °C, which is consistent with the standard temperature regime, compared to 967.96 °C and 956.15 °C for the Automatic and MultiZone methods, respectively. Similarly, reinforcement temperatures followed the same trend: 887.49 °C for Body Sizing versus 936.52 °C for Automatic and 897.44 °C for MultiZone.The study emphasizes the importance of selecting an optimal finite element model to evaluate fire resistance accurately. This research contributes to improving fire safety assessments by enabling more precise predictions of the thermal behavior of reinforced concrete structures. Such findings are essential for designing safe and efficient structural systems, ensuring compliance with fire resistance standards, and enhancing the performance of building components under fire exposure.The results are valuable for professionals involved in structural design and fire safety engineering, offering a foundation for developing advanced modeling techniques to predict and improve the fire resistance of ribbed slabs and similar constructions.
- Open Access
- 1 January 2023
- Published by National University of Civil Protection of Ukraine in Emergency Situations: Prevention and Liquidation
- Vol. 7 (2) , 19-28
INFLUENCE OF THE RATIO OF FIRE PROTECTION COMPONENTS ON THE FIRE PROTECTION EFFICIENCY OF WATER BASED COATINGS OF METAL STRUCTURES
The creation of polymer fire-resistant coatings for metal structures has always been and remains one of the priority areas of fire protection of buildings and structures, since the material costs of recovery after a fire many times exceed the costs of preventive fire protection measures.In addition to providing the properties required for most paint materials, the film-forming component must decompose in the correct temperature range along with the other flame retardant components to be able to undergo the chemical reactions that result in the formation of foamcoke. Moreover, it should have a melt viscosity that is not too low to prevent the molten flame retardant coating from slipping during foaming, and not too high to prevent foaming.As a result of the conducted experimental studies on the determination of the coefficient of swelling, its strength and the group of fire-resistant efficiency, developed fire-resistant coatings based on styrene-acrylic water dispersion from the content of fire-resistant components it was established that all experimental coatings have the first group of fire protection efficiency. Foamcoke, formed by PFA components 25 mas.%, PE 15-25 mas.%, Al(OH)3 40 mas.% has a porous structure, uniform, dense and small cells, without microcracks and large cavities, which provides better insulating properties.
- 1 January 2023
- Published by National University of Civil Protection of Ukraine in Emergency Situations: Prevention and Liquidation
- Vol. 7 (2) , 19-28
Open AccessINFLUENCE OF THE RATIO OF FIRE PROTECTION COMPONENTS ON THE FIRE PROTECTION EFFICIENCY OF WATER BASED COATINGS OF METAL STRUCTURES
The creation of polymer fire-resistant coatings for metal structures has always been and remains one of the priority areas of fire protection of buildings and structures, since the material costs of recovery after a fire many times exceed the costs of preventive fire protection measures.In addition to providing the properties required for most paint materials, the film-forming component must decompose in the correct temperature range along with the other flame retardant components to be able to undergo the chemical reactions that result in the formation of foamcoke. Moreover, it should have a melt viscosity that is not too low to prevent the molten flame retardant coating from slipping during foaming, and not too high to prevent foaming.As a result of the conducted experimental studies on the determination of the coefficient of swelling, its strength and the group of fire-resistant efficiency, developed fire-resistant coatings based on styrene-acrylic water dispersion from the content of fire-resistant components it was established that all experimental coatings have the first group of fire protection efficiency. Foamcoke, formed by PFA components 25 mas.%, PE 15-25 mas.%, Al(OH)3 40 mas.% has a porous structure, uniform, dense and small cells, without microcracks and large cavities, which provides better insulating properties.
- Open Access
- 1 January 2023
- Published by National University of Civil Protection of Ukraine in Emergency Situations: Prevention and Liquidation
- Vol. 7 (2) , 217-226
STUDY OF THE FIRE RESISTANCE OF A REINFORCED CONCRETE SLAB
The work presents an algorithm for carrying out a refined method of calculating the fire resistance of a reinforced concrete ribbed slab modeled according to the design type PR 63-15 when using the finite element method. The parameters of the Drucker–Prager theory of concrete strength were used in the calculations. The finite-element model consisted of more than 13,000 finite elements of hexahedral shape.To solve the thermal problem, the thermophysical characteristics of concrete and steel reinforcement were used, which correspond to the temperature dependences recommended by the second part of Eurocode 2. To reproduce the heat exchange during the influence of the standard temperature regime of the fire, an unsteady two-dimensional quasi-linear equation of thermal conductivity is used, assuming that the stress-strain state does not affect the temperature distribution. Boundary conditions of the IIIrd kind are given, which is also recommended for the second part of Eurocode 2. The results of the temperature distribution in the simulated reinforced concrete ribbed slab during 60 min are obtained. The temperature indicators were used in solving the compatible thermomechanical problem of evaluating the fire resistance of the studied reinforced concrete ribbed slab at 50%, 70% and 100% load level from the maximum. The fire resistance of the board was evaluated according to the limit state of the loss of load-bearing capacity (R) without taking into account the formation of cracks or through defects. The maximum stresses in the concrete of the studied structure, which are formed during deformations at different load levels, are observed in the upper part of the longitudinal ribs and exceed 30 MPa, which is critical for concrete with such compressive strength.Based on the results of the research, a regularity was determined that establishes the relationship between fire resistance indicators and the level of applied mechanical load.
- 1 January 2023
- Published by National University of Civil Protection of Ukraine in Emergency Situations: Prevention and Liquidation
- Vol. 7 (2) , 217-226
Open AccessSTUDY OF THE FIRE RESISTANCE OF A REINFORCED CONCRETE SLAB
The work presents an algorithm for carrying out a refined method of calculating the fire resistance of a reinforced concrete ribbed slab modeled according to the design type PR 63-15 when using the finite element method. The parameters of the Drucker–Prager theory of concrete strength were used in the calculations. The finite-element model consisted of more than 13,000 finite elements of hexahedral shape.To solve the thermal problem, the thermophysical characteristics of concrete and steel reinforcement were used, which correspond to the temperature dependences recommended by the second part of Eurocode 2. To reproduce the heat exchange during the influence of the standard temperature regime of the fire, an unsteady two-dimensional quasi-linear equation of thermal conductivity is used, assuming that the stress-strain state does not affect the temperature distribution. Boundary conditions of the IIIrd kind are given, which is also recommended for the second part of Eurocode 2. The results of the temperature distribution in the simulated reinforced concrete ribbed slab during 60 min are obtained. The temperature indicators were used in solving the compatible thermomechanical problem of evaluating the fire resistance of the studied reinforced concrete ribbed slab at 50%, 70% and 100% load level from the maximum. The fire resistance of the board was evaluated according to the limit state of the loss of load-bearing capacity (R) without taking into account the formation of cracks or through defects. The maximum stresses in the concrete of the studied structure, which are formed during deformations at different load levels, are observed in the upper part of the longitudinal ribs and exceed 30 MPa, which is critical for concrete with such compressive strength.Based on the results of the research, a regularity was determined that establishes the relationship between fire resistance indicators and the level of applied mechanical load.