Liren Pang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Liren Pang has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Hongli Liu
National Gravitation Laboratory, MOE Key Laboratory of Fundamental Physical Quantities Measurement, and School of Physics, Huazhong University of Science and Technology, Wuhan 430074, People’s Republic of China
2 shared publications - Jie Zhang
Huazhong University of Science and Technology
2 shared publications - Ke Deng
National Gravitation Laboratory, MOE Key Laboratory of Fundamental Physical Quantities Measurement, School of Physics Huazhong University of Science and Technology Wuhan China
2 shared publications - Zehuang Lu
National Gravitation Laboratory, MOE Key Laboratory of Fundamental Physical Quantities Measurement, and School of Physics, Huazhong University of Science and Technology, Wuhan 430074, People’s Republic of China
2 shared publications - Zhiyu Ma
National Gravitation Laboratory, MOE Key Laboratory of Fundamental Physical Quantities Measurement, and School of Physics, Huazhong University of Science and Technology, Wuhan 430074, People’s Republic of China
2 shared publications Biao Wang
National Gravitation Laboratory, MOE Key Laboratory of Fundamental Physical Quantities Measurement, and School of Physics, Huazhong University of Science and Technology, Wuhan 430074, People’s Republic of China
1 shared publication
Latest Publications
- 14 July 2025
- Published by IOP Publishing in Metrologia
- Vol. 62 (4) , 045002
Absolute frequency measurement of an Al + ion optical clock through a GNSS link to the SI second
We report an absolute frequency measurement of the 27 Al + ion 1 S 0 ↔ 3 P 0 optical clock transition, through a GNSS link to International Atomic Time (TAI) to ensure the traceability to the International System of Units (SI) second. The data were taken over a 22 d period, with the absolute frequency measured to be 1 121 015 393 207 856(16) Hz, with a relative standard uncertainty of 1.4 × 10 − 14 . The result confirms the reliability of the 27 Al + ion as a secondary representation of the SI second and contributes to the process of redefining the SI second based on optical transitions.
- 14 July 2025
- Published by IOP Publishing in Metrologia
- Vol. 62 (4) , 045002
Absolute frequency measurement of an Al + ion optical clock through a GNSS link to the SI second
We report an absolute frequency measurement of the 27 Al + ion 1 S 0 ↔ 3 P 0 optical clock transition, through a GNSS link to International Atomic Time (TAI) to ensure the traceability to the International System of Units (SI) second. The data were taken over a 22 d period, with the absolute frequency measured to be 1 121 015 393 207 856(16) Hz, with a relative standard uncertainty of 1.4 × 10 − 14 . The result confirms the reliability of the 27 Al + ion as a secondary representation of the SI second and contributes to the process of redefining the SI second based on optical transitions.
- 1 December 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (12)
A compact and fast radio-frequency source for efficient Raman sideband cooling
A compact and fast radio-frequency (RF) source developed for Raman sideband cooling (RSBC) in trapped ion and cold atom experiments is presented. The source is based on direct digital synthesizer, advanced real-time infrastructure for quantum physics, and field programmable gate array. The source has a frequency switching speed of 40 ns and can output continuous μs-level time sequences for RSBC. The maximum output frequency of the source is 1.4 GHz. The RF source is capable of pre-writing data for eight channels. As a demonstration, the RF source is applied to our 25Mg+–27Al+ ion pair optical clock experiment. In order to cool down the ion pair to the vibrational ground state, two-order RSBC is applied to the 25Mg+ ion. As a result, the ion pair motions in the three X, Y, and Z directions are all cooled to the vibrational ground state efficiently, demonstrating the feasibility of this technique. The developed RF source can be widely implemented for other cold atom experiments.
- 1 December 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (12)
A compact and fast radio-frequency source for efficient Raman sideband cooling
A compact and fast radio-frequency (RF) source developed for Raman sideband cooling (RSBC) in trapped ion and cold atom experiments is presented. The source is based on direct digital synthesizer, advanced real-time infrastructure for quantum physics, and field programmable gate array. The source has a frequency switching speed of 40 ns and can output continuous μs-level time sequences for RSBC. The maximum output frequency of the source is 1.4 GHz. The RF source is capable of pre-writing data for eight channels. As a demonstration, the RF source is applied to our 25Mg+–27Al+ ion pair optical clock experiment. In order to cool down the ion pair to the vibrational ground state, two-order RSBC is applied to the 25Mg+ ion. As a result, the ion pair motions in the three X, Y, and Z directions are all cooled to the vibrational ground state efficiently, demonstrating the feasibility of this technique. The developed RF source can be widely implemented for other cold atom experiments.