Rebekah L. Schrader
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rebekah L. Schrader has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Gavin P. Horn
Fire Safety Research Institute, UL Research Institutes, Columbia, USA
4 shared publications - Joseph M. Willi
Fire Safety Research Institute, UL Research Institutes, Columbia, USA
4 shared publications - Nicholas Dow
Fire Safety Research Institute, UL Research Institutes, Columbia, USA
3 shared publications - Amy J. Metz
School of Civil and Construction Engineering, Oregon State University, Corvallis, USA
2 shared publications - Brad Parker Wham
Univ. of Colorado Boulder
2 shared publications - Erica C. Fischer
Oregon State Univ
2 shared publications
Latest Publications
- Open Access
- 8 May 2026
- Published by Springer Nature in Fire Technology
- Vol. 62 (4)
Window Frame Failure During Exterior Fire Exposure
- 8 May 2026
- Published by Springer Nature in Fire Technology
- Vol. 62 (4)
Open AccessWindow Frame Failure During Exterior Fire Exposure
- Open Access
- 31 March 2026
- Published by Springer Nature in Fire Technology
- Vol. 62 (3)
Assessing Water Quality Impacts of Wildfire-Induced Depressurization in Water Systems: VOC Analysis Results
- 31 March 2026
- Published by Springer Nature in Fire Technology
- Vol. 62 (3)
Open AccessAssessing Water Quality Impacts of Wildfire-Induced Depressurization in Water Systems: VOC Analysis Results
- Open Access
- 7 January 2026
- Published by Springer Nature in Fire Technology
- Vol. 62 (1) , 9
Assessing Water Quality Impacts of Wildfire-Induced Depressurization in Water Systems: an Experimental Method
In the past decade, communities have detected volatile organic compounds (VOCs) in their water distribution systems following wildfire impacts (e.g. system damage and depressurization). This study outlines a comprehensive experimental framework developed to quantify the effects of localized water system depressurization (e.g. loss of pressure at a house) as a mechanism for VOC contamination in water systems following wildfire events. The methodology employs a modular, instrumented vacuum test setup connected to a compartment with a consistent, well-characterized fuel load. The modular design facilitates targeted experimentation, enabling researchers to assess specific parameters influencing VOC contamination during local depressurization. The integration of sensors and video imagery enables researchers to quantify results within specific fire exposures and depressurization conditions. The integrated sensors and imagery allows for conditions—such as temperature, airflow rate, and material deformations—to be continuously monitored. Proposed sampling protocols provide methods for post-test sampling to quantify total system exposure to VOCs from the burning compartment and the response of the system components to that exposure, such as the levels of VOCs leached from pipes post-exposure and how system recovery techniques may influence concentrations of VOCs leached. Though these methods are presented in the context of VOC contamination from localized depressurization, the framework can be adapted to investigate other water system concerns following pressure loss, such as pathogens, turbidity, and heavy metals. The presented methodology provides a preliminary framework for assessing depressurization-induced contamination and the effectiveness of recovery strategies in fire-affected water systems.
- 7 January 2026
- Published by Springer Nature in Fire Technology
- Vol. 62 (1) , 9
Open AccessAssessing Water Quality Impacts of Wildfire-Induced Depressurization in Water Systems: an Experimental Method
In the past decade, communities have detected volatile organic compounds (VOCs) in their water distribution systems following wildfire impacts (e.g. system damage and depressurization). This study outlines a comprehensive experimental framework developed to quantify the effects of localized water system depressurization (e.g. loss of pressure at a house) as a mechanism for VOC contamination in water systems following wildfire events. The methodology employs a modular, instrumented vacuum test setup connected to a compartment with a consistent, well-characterized fuel load. The modular design facilitates targeted experimentation, enabling researchers to assess specific parameters influencing VOC contamination during local depressurization. The integration of sensors and video imagery enables researchers to quantify results within specific fire exposures and depressurization conditions. The integrated sensors and imagery allows for conditions—such as temperature, airflow rate, and material deformations—to be continuously monitored. Proposed sampling protocols provide methods for post-test sampling to quantify total system exposure to VOCs from the burning compartment and the response of the system components to that exposure, such as the levels of VOCs leached from pipes post-exposure and how system recovery techniques may influence concentrations of VOCs leached. Though these methods are presented in the context of VOC contamination from localized depressurization, the framework can be adapted to investigate other water system concerns following pressure loss, such as pathogens, turbidity, and heavy metals. The presented methodology provides a preliminary framework for assessing depressurization-induced contamination and the effectiveness of recovery strategies in fire-affected water systems.
- Open Access
- 8 January 2025
- Published by Springer Nature in Fire Technology
- Vol. 61 (4) , 2361-2387
Experimental Study of Heat Transfer Through Windows Exposed to a Radiant Panel Heater
Structure hardening is a key strategy to help mitigate building destruction during wildland-urban interface fires. Windows represent an important vulnerability for structure failure by allowing heat transfer to interior combustibles, and in cases of mechanical failure, an entry point for flames and/or embers. The purpose of this study is to characterize heat transfer through windows with various common construction variables (plain (annealed) versus tempered glass, single- versus double-pane, low-emissivity coating versus no coating, and air-filled versus argon-filled pane gap). Small-scale experiments were performed with 23 cm by 23 cm windows exposed to a radiant panel producing centerpoint incident heat fluxes of 10 $$\hbox {kW/m}^{2}$$ , 20 $$\hbox {kW/m}^{2}$$ , 30 $$\hbox {kW/m}^{2}$$ , 40 $$\hbox {kW/m}^{2}$$ , and 50 $$\hbox {kW/m}^{2}$$ . Total heat flux was measured 5.1 cm behind the window glass. Times of pane cracking and other failure events were recorded. Double-pane designs reduced heat transfer through a window more than the single-pane design (measured 13% to 43% and 39% to 60% of the incident heat flux, respectively). Heat transfer was further reduced when a low-emissivity coating was present (measured 5 to 14% of the incident heat flux). The differences in measured heat flux behind plain glass versus tempered glass windows and air-filled versus argon-filled windows were not statistically significant. Tempered glass performed better than plain glass, and double-pane argon-filled windows consistently survived longer than double-pane air-filled windows. In some cases, heat fluxes measured behind the windows surpassed the critical heat flux required for ignition of some common household combustibles.- 8 January 2025
- Published by Springer Nature in Fire Technology
- Vol. 61 (4) , 2361-2387
Open AccessExperimental Study of Heat Transfer Through Windows Exposed to a Radiant Panel Heater
Structure hardening is a key strategy to help mitigate building destruction during wildland-urban interface fires. Windows represent an important vulnerability for structure failure by allowing heat transfer to interior combustibles, and in cases of mechanical failure, an entry point for flames and/or embers. The purpose of this study is to characterize heat transfer through windows with various common construction variables (plain (annealed) versus tempered glass, single- versus double-pane, low-emissivity coating versus no coating, and air-filled versus argon-filled pane gap). Small-scale experiments were performed with 23 cm by 23 cm windows exposed to a radiant panel producing centerpoint incident heat fluxes of 10 $$\hbox {kW/m}^{2}$$ , 20 $$\hbox {kW/m}^{2}$$ , 30 $$\hbox {kW/m}^{2}$$ , 40 $$\hbox {kW/m}^{2}$$ , and 50 $$\hbox {kW/m}^{2}$$ . Total heat flux was measured 5.1 cm behind the window glass. Times of pane cracking and other failure events were recorded. Double-pane designs reduced heat transfer through a window more than the single-pane design (measured 13% to 43% and 39% to 60% of the incident heat flux, respectively). Heat transfer was further reduced when a low-emissivity coating was present (measured 5 to 14% of the incident heat flux). The differences in measured heat flux behind plain glass versus tempered glass windows and air-filled versus argon-filled windows were not statistically significant. Tempered glass performed better than plain glass, and double-pane argon-filled windows consistently survived longer than double-pane air-filled windows. In some cases, heat fluxes measured behind the windows surpassed the critical heat flux required for ignition of some common household combustibles.