Experimental Study of Heat Transfer Through Windows Exposed to a Radiant Panel Heater
Open Access
- 8 January 2025
- journal article
- research article
- Published by Springer Nature in Fire Technology
- Vol. 61 (4) , 2361-2387
Abstract
Structure hardening is a key strategy to help mitigate building destruction during wildland-urban interface fires. Windows represent an important vulnerability for structure failure by allowing heat transfer to interior combustibles, and in cases of mechanical failure, an entry point for flames and/or embers. The purpose of this study is to characterize heat transfer through windows with various common construction variables (plain (annealed) versus tempered glass, single- versus double-pane, low-emissivity coating versus no coating, and air-filled versus argon-filled pane gap). Small-scale experiments were performed with 23 cm by 23 cm windows exposed to a radiant panel producing centerpoint incident heat fluxes of 10 $$\hbox {kW/m}^{2}$$ , 20 $$\hbox {kW/m}^{2}$$ , 30 $$\hbox {kW/m}^{2}$$ , 40 $$\hbox {kW/m}^{2}$$ , and 50 $$\hbox {kW/m}^{2}$$ . Total heat flux was measured 5.1 cm behind the window glass. Times of pane cracking and other failure events were recorded. Double-pane designs reduced heat transfer through a window more than the single-pane design (measured 13% to 43% and 39% to 60% of the incident heat flux, respectively). Heat transfer was further reduced when a low-emissivity coating was present (measured 5 to 14% of the incident heat flux). The differences in measured heat flux behind plain glass versus tempered glass windows and air-filled versus argon-filled windows were not statistically significant. Tempered glass performed better than plain glass, and double-pane argon-filled windows consistently survived longer than double-pane air-filled windows. In some cases, heat fluxes measured behind the windows surpassed the critical heat flux required for ignition of some common household combustibles.
Keywords
This publication has 36 references indexed in Scilit:
- Radiant Ignition of Polyurethane Foam: The Effect of Sample SizeFire Technology, 2012
- Transmission Through and Breakage of Single and Multi-Pane Glazing Due to Radiant Exposure: State of ResearchFire Technology, 2010
- Full‐scale experimental study on crack and fallout of toughened glass with different thicknessesFire and Materials, 2008
- Transmission Through and Breakage of Multi-Pane Glazing Due to Radiant ExposureFire Technology, 2006
- Behaviour of Double Glazing in Corner FiresFire Technology, 2005
- Performance of a single glazing assembly exposed to a fire in the centre of an enclosureFire and Materials, 2002
- Performance of a single glazing assembly exposed to enclosure corner fires of increasing severityFire and Materials, 2001
- The performance of aluminium building products in bushfiresFire and Materials, 1991
- Breaking of window glass close to fireFire and Materials, 1988
- Preliminary results from an examination of house survival in the 16 February 1983 Bushfires in AustraliaFire and Materials, 1987