Yuan Fu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yuan Fu has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Changchuan Li
Department of Orthopaedic Surgery, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, 510120, People’s Republic of China
1 shared publication - Dezhi Zheng
School of Interdisciplinary Science, Beijing Institute of Technology, Beijing, China
1 shared publication - Guibin Fang
Department of Orthopedics, Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, China
1 shared publication - Guowen Jiang
Baoding, China, 071000
1 shared publication - Junxiong Qiu
Department of Cardiovascular Surgery, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
1 shared publication - Kun Xia
Department of Cardiology, Chaoyang Hospital, Beijing 100020, China
1 shared publication
Latest Publications
- 9 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
Laser Differential Confocal Freeform Surface Shape Measurement Based on Monitoring and Compensation of Translational Motion Error
The manufacturing accuracy of freeform surface is limited by its detection accuracy. In this paper, a laser differential confocal freeform surface shape measurement method based on translational motion error monitoring and compensation is proposed. This method realizes helical scanning measurements of a freeform surface via sensor translation and freeform surface rotation. Based on normal tracking principle, a position-sensitive detector is used to track the normal direction, solving the problem of large inclination freeform surface measurements limited by the maximum measurable inclination of the sensor. The laser differential confocal sensor is used to precisely focus of the surface, realizing a high-spatial-resolution measurement of the surface normal vector, with an axial resolution of up to 1 nm. By introducing a reference frame into the system, an independent translational motion reference is provided for freeform surface measurement. By monitoring, decoupling and compensating the 2D translational motion errors, the impact of these errors on measurement accuracy is greatly reduced. High-accuracy freeform surface shape measurement is finally realized. The experimental results show that after error compensation, the PV repeatability is superior to ±50 nm (3σ), RMS repeatability is superior to ±14 nm (3σ), and the measurement results are close to the standard values, enabling high-accuracy measurement of freeform surface shapes.
- 9 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
Laser Differential Confocal Freeform Surface Shape Measurement Based on Monitoring and Compensation of Translational Motion Error
The manufacturing accuracy of freeform surface is limited by its detection accuracy. In this paper, a laser differential confocal freeform surface shape measurement method based on translational motion error monitoring and compensation is proposed. This method realizes helical scanning measurements of a freeform surface via sensor translation and freeform surface rotation. Based on normal tracking principle, a position-sensitive detector is used to track the normal direction, solving the problem of large inclination freeform surface measurements limited by the maximum measurable inclination of the sensor. The laser differential confocal sensor is used to precisely focus of the surface, realizing a high-spatial-resolution measurement of the surface normal vector, with an axial resolution of up to 1 nm. By introducing a reference frame into the system, an independent translational motion reference is provided for freeform surface measurement. By monitoring, decoupling and compensating the 2D translational motion errors, the impact of these errors on measurement accuracy is greatly reduced. High-accuracy freeform surface shape measurement is finally realized. The experimental results show that after error compensation, the PV repeatability is superior to ±50 nm (3σ), RMS repeatability is superior to ±14 nm (3σ), and the measurement results are close to the standard values, enabling high-accuracy measurement of freeform surface shapes.
- Open Access
- 1 June 2023
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2537 (1) , 012001
Research on Control Strategy of Constant Power Output in MCRWPT System
During wireless charging, the change of battery resistance will cause the fluctuation of output power, which will shorten the battery life and affect the charging safety. According to the theoretical analysis of WPT, when the load resistance changes, the output power can be stabilized by adjusting the input voltage of the system. Aiming at the variable load MCRWPT system, that is, only the load resistance changes under the resonant state, this paper designs the MCRWPT constant power control system by using the principle of reflective impedance and using the phase-shifting control voltage regulation and builds a simulation model through Matlab/Simulink platform to verify that the output power is kept in a certain range, without additional communication loops, which reduces the volume of electrical equipment and saves costs.
- 1 June 2023
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2537 (1) , 012001
Open AccessResearch on Control Strategy of Constant Power Output in MCRWPT System
During wireless charging, the change of battery resistance will cause the fluctuation of output power, which will shorten the battery life and affect the charging safety. According to the theoretical analysis of WPT, when the load resistance changes, the output power can be stabilized by adjusting the input voltage of the system. Aiming at the variable load MCRWPT system, that is, only the load resistance changes under the resonant state, this paper designs the MCRWPT constant power control system by using the principle of reflective impedance and using the phase-shifting control voltage regulation and builds a simulation model through Matlab/Simulink platform to verify that the output power is kept in a certain range, without additional communication loops, which reduces the volume of electrical equipment and saves costs.
- 25 April 2023
- Published by Springer Nature
- p. 967-975
Wind Turbine Virtual Inertia Quantization Control Method Based on Additional Speed Control
- 25 April 2023
- Published by Springer Nature
- p. 967-975
Wind Turbine Virtual Inertia Quantization Control Method Based on Additional Speed Control
- Open Access
- 28 December 2021
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 21 (1) , 1-5
Coronary catheterization via distal transradial access in patient with superficial radial artery: a case report
Background: The routine radial artery (RA) puncture may fail when anatomical variation of the RA is encountered. Superficial radial artery (SRA) is one of the anatomic variants of the RA, with the incidence of about 1 to 1.5%. Recently, distal transradial access (dTRA) has emerged as a novel approach for coronary catheterization (CC), but performing CC through dTRA in patient with SRA has never been reported. Case presentation: A 57-year-old male was admitted to hospital due to intermittent chest pain for 4 days. He was diagnosed with unstable angina pectoris and planned to receive coronary angiography (CAG). Before the operation, the existence and course of SRA were confirmed by palpation and ultrasonography with color Doppler. We marked the puncture site under the guidance of ultrasonography and successfully performed CC through the dTRA during patient’s hospitalization. Conclusions: As far as we know, this is the first report that presents a case of SRA and percutaneous coronary intervention (PCI) treatment in which was successfully performed through dTRA. It is safe and feasible to perform CC via dTRA in case of SRA, and dTRA seems to be the preferred access.
- 28 December 2021
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 21 (1) , 1-5
Open AccessCoronary catheterization via distal transradial access in patient with superficial radial artery: a case report
Background: The routine radial artery (RA) puncture may fail when anatomical variation of the RA is encountered. Superficial radial artery (SRA) is one of the anatomic variants of the RA, with the incidence of about 1 to 1.5%. Recently, distal transradial access (dTRA) has emerged as a novel approach for coronary catheterization (CC), but performing CC through dTRA in patient with SRA has never been reported. Case presentation: A 57-year-old male was admitted to hospital due to intermittent chest pain for 4 days. He was diagnosed with unstable angina pectoris and planned to receive coronary angiography (CAG). Before the operation, the existence and course of SRA were confirmed by palpation and ultrasonography with color Doppler. We marked the puncture site under the guidance of ultrasonography and successfully performed CC through the dTRA during patient’s hospitalization. Conclusions: As far as we know, this is the first report that presents a case of SRA and percutaneous coronary intervention (PCI) treatment in which was successfully performed through dTRA. It is safe and feasible to perform CC via dTRA in case of SRA, and dTRA seems to be the preferred access.
- 14 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 36 (4) , 3496-3506
Transient Voltage Recovery Control and Stability Criterion of VSC-Based DC Power Grid
Transient recovery characteristics of DC voltage are critical to analyze the stability criterion and the fault ride-through capability of voltage source converter (VSC)-based DC power systems. In this paper, the dynamic model of a flexible DC power grid was initially established, and then, the dynamic operation mechanism of the system was presented by analyzing the movement locus of the operating point when disturbances occur in the DC grid. Subsequently, the DC transient voltage limit and the DC fault clearing time were calculated in order to obtain the transient stability criterion of the DC power system. In addition, a novel voltage transient recovery control strategy was proposed by improving the droop control of the DC voltage to extend the transient stability margin of the power system. Finally, a typical multi-terminal flexible DC power grid was developed on a hardware-in-the-loop platform. The results demonstrated that the voltage recovery ability of the DC power system can be quantitatively estimated by the stability criterion, while the system transient stability can be improved by the proposed control strategy.
- 14 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 36 (4) , 3496-3506
Transient Voltage Recovery Control and Stability Criterion of VSC-Based DC Power Grid
Transient recovery characteristics of DC voltage are critical to analyze the stability criterion and the fault ride-through capability of voltage source converter (VSC)-based DC power systems. In this paper, the dynamic model of a flexible DC power grid was initially established, and then, the dynamic operation mechanism of the system was presented by analyzing the movement locus of the operating point when disturbances occur in the DC grid. Subsequently, the DC transient voltage limit and the DC fault clearing time were calculated in order to obtain the transient stability criterion of the DC power system. In addition, a novel voltage transient recovery control strategy was proposed by improving the droop control of the DC voltage to extend the transient stability margin of the power system. Finally, a typical multi-terminal flexible DC power grid was developed on a hardware-in-the-loop platform. The results demonstrated that the voltage recovery ability of the DC power system can be quantitatively estimated by the stability criterion, while the system transient stability can be improved by the proposed control strategy.
- Open Access
- 1 May 2020
- Published by Elsevier in Journal of Biological Chemistry
- Vol. 295 (20) , 7018-7032
The USP14–NLRC5 pathway inhibits titanium particle–induced osteolysis in mice by suppressing NF-κB and PI3K/AKT activities
- 1 May 2020
- Published by Elsevier in Journal of Biological Chemistry
- Vol. 295 (20) , 7018-7032
Open AccessThe USP14–NLRC5 pathway inhibits titanium particle–induced osteolysis in mice by suppressing NF-κB and PI3K/AKT activities