    Measurement Lag Sets a Stability Limit in Single-Phase Virtual Synchronous Machines: Why the SOGI Is Not Lag-Free

    by Fikri Waskito, Franscisco Danang Wijaya, Eka Firmansyah

    The power measurement stage of a single-phase virtual synchronous machine(VSM) sets a hard stability limit. This paper derives that limit in closedform. The Routh–Hurwitz condition reduces to the sign of a quadratic inthe normalized filter cutoff. Its coefficients depend on only two dimensionlessgroups, so a single chart covers every rating and operating point. The limitexists because the measurement lag and the governor lag draw on the sameswing-mode damping, and neither can be designed on its own. The resultalso corrects a common assumption. A second-order generalized integrator(SOGI) is usually treated as lag-free, because it cancels the 2ω ripple exactlyin steady state. We show that the power envelope still sees a first-orderlag, of equivalent cutoff feq = kf0/2. A textbook gain of k = √2 thereforedestabilizes the machine at plausible governor lags. Low-pass, notch andSOGI schemes are then read from one chart. Coupling to a weak grid raisesthe limit by 1.45 to 1.65 times, and at common governor tunings no first-order low-pass filter is usable at all. A fixed 100-Hz notch keeps about 35×ripple rejection across the grid-code band without adaptive tuning. The limitis validated three ways: a 20-kHz switched simulation (rates within 4–8%),a Floquet analysis of the ripple-carrying system, and controller-hardware-in-the-loop tests, in which the measured critical cutoff falls within 3% of theprediction.

  • Open Access

    Reactive Power Control Modes in Smart Inverters for Overvoltage Mitigation: Impacts on LVRT Performance—A Case Study in Gorontalo, Indonesia

    by Muammar Zainuddin, M. Isnaeni Bambang Setyonegoro, Eka Firmansyah, Tumiran

    The increasing penetration of photovoltaic (PV) power generation into distribution networks presents an overvoltage challenge during normal operations. Smart inverter reactive power control modes are promising solutions to address this challenge. To mitigate overvoltage, reactive power control modes are commonly configured with conservative limits to protect equipment. However, during severe faults, a higher reactive current availability is required to comply with low-voltage ride-through (LVRT) requirements. Therefore, reactive power control modes should be capable of operating under both normal and fault conditions. This study investigated how the standard reactive power control modes used for overvoltage mitigation affected the LVRT performance. A case study was conducted on a 2 MWp PV plant connected to a real medium-voltage feeder in Gorontalo, Indonesia, which experienced overvoltage during peak PV injection. To assess this impact, a multifunctional control framework was developed that integrated a reactive power controller (Fixed VAr, Fixed power factor, Watt–VAr, and Volt–VAr), fault detection logic, an LVRT mechanism, and a current limiting scheme. Three-phase symmetrical faults were simulated with variations in the reactive power limits, voltage sag depths, and delayed fault clearing. The results showed a clear trade-off: tighter reactive power limits reduced steady-state overvoltage but degraded LVRT performance by lowering reactive current injection and delaying voltage recovery. Moreover, each control mode exhibited distinct dynamic responses, implying different parameter-setting priorities. These findings underscore the need to configure reactive power limits and firmware parameters to sustain overvoltage mitigation during normal operation, while preserving LVRT during faults.

  • BLDC Motor Sizing Analysis on P1 Topology Hybridization of Single Cylinder ICE

    by I Wayan Adiyasa, Fransisco Danang Wijaya, Eka Firmansyah

    The hybridization process of a motorcycle with a P1 configuration identifies the performance of an electric motor at the same speed point or more on an internal combustion engine (ICE). The targeted speed is the highest torque point on the ICE. This condition is often called torque assist. Most starter motors on conventional motorcycles operate at cranking speed. The use of starter motors in the latest technology uses a BLDC electric motor. The advancement of controllers and starter motor topology enables the BLDC electric motor to run at its maximum torque point speed on the ICE. Generally., ICE designs that have BLDC electric motors use P1 hybrid topology or are often called integrated starter-generator (ISG). The paper focuses on the analysis of the sizing of BLDC electric motors to be able to operate as ISGs at the highest torque point speed on the ICE. The constraints in the paper are in the form of operating voltage parameters., wire diameter., and number of turns. Changes in these values achieve a greater motor torque equal to its base torque and a motor speed greater than its base speed. The sizing results show an increase in speed of up to 3000 rpm with operating temperature conditions for 60 minutes maintained at 50.2 °C. The reduction in fuel consumption during vehicle dynamics testing reached 1,376% in the ECE-R15 driving cycle, 1,033 in the ECE-R40 driving cycle, and 1,217 in the WMTC driving cycle.