Ernesto Gomez Tamm
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ernesto Gomez Tamm has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Hodul
Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
1 shared publication - Elmar Laistler
High Field MR Center, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria; Christian Doppler Laboratory for Patient-Centered Breast Imaging, Medical University of Vienna, Vienna, Austria
1 shared publication - Ivo Rausch
Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
1 shared publication - Jean-Lynce Gnanago
Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
1 shared publication - Karyna Isaieva
IADI U1254, Inserm, Université de Lorraine, Nancy, France
1 shared publication - Lena Nohava
High Field MR Center, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
1 shared publication
Latest Publications
- 14 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Modular Dynamic Torso Phantom Featuring Respiratory and Cardiac Motion for Magnetic Resonance Imaging
The design, fabrication, assembly and testing of a modular dynamic torso phantom for magnetic resonance imaging (MRI) is presented. The phantom is composed of fully MRI-compatible materials and consists of a saline-filled acrylic shell, with dimensions comparable to a human torso, and three distinct interior motion modules. Two linear piezo stages are used to mimic respiratory motion of the chest-wall (≤ 10 mm; cycle time ≥ 2 s) and the abdominal organs (≤ 45 mm; cycle time ≥ 2 s). A pneumatic system is used to move a heart mock-up to represent cardiac motion (≤ 19 mm, rate ≤ 3 Hz). The motion capabilities and MRI compatibility of the phantom are tested in 3 T MRI experiments. The closed-loop control of the phantom’s breathing modules allows for accurate positioning and timing with absolute differences between input and output values ≤ 0.61 mm and ≤ 0.06 s. The purpose of this phantom is to serve as a scientific instrument for the future development and evaluation of motion tracking and artifact compensation techniques.
- 14 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Modular Dynamic Torso Phantom Featuring Respiratory and Cardiac Motion for Magnetic Resonance Imaging
The design, fabrication, assembly and testing of a modular dynamic torso phantom for magnetic resonance imaging (MRI) is presented. The phantom is composed of fully MRI-compatible materials and consists of a saline-filled acrylic shell, with dimensions comparable to a human torso, and three distinct interior motion modules. Two linear piezo stages are used to mimic respiratory motion of the chest-wall (≤ 10 mm; cycle time ≥ 2 s) and the abdominal organs (≤ 45 mm; cycle time ≥ 2 s). A pneumatic system is used to move a heart mock-up to represent cardiac motion (≤ 19 mm, rate ≤ 3 Hz). The motion capabilities and MRI compatibility of the phantom are tested in 3 T MRI experiments. The closed-loop control of the phantom’s breathing modules allows for accurate positioning and timing with absolute differences between input and output values ≤ 0.61 mm and ≤ 0.06 s. The purpose of this phantom is to serve as a scientific instrument for the future development and evaluation of motion tracking and artifact compensation techniques.