Lukas Jakob Moser
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lukas Jakob Moser has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Hatem Alkadhi
Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
7 shared publications - Matthias Eberhard
Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland
6 shared publications - Victor Mergen
Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
6 shared publications - Konstantin Klambauer
Department of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Raemistrasse 100, 8091 Zurich, Switzerland
5 shared publications - Bernhard Schmidt
Siemens Healthcare GmbH, 91052 Erlangen, Germany
4 shared publications - Thomas Allmendinger
From the Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland (L.J.M., V.M., R.M., M.E., H.A.); Siemens Healthineers AG, Forchheim, Germany (T.A.); and Department of Radiology, Spital Interlaken, Spitäler fmi AG, Unterseen, Switzerland (M.E.).
3 shared publications
Latest Publications
- Open Access
- 1 December 2025
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 61 (8) , 568-574
High-Z Contrast Media for Coronary Photon-counting Detector CT Angiography
Background: Blooming artifacts from calcified plaques can obscure the vessel lumen, leading to overestimation of stenosis severity. Spectral coronary angiography with photon-counting detector CT (PCD-CT) provides virtual monoenergetic images (VMIs) for coronary artery disease assessment. While VMIs at high VMI energy levels reduce calcium blooming, iodine contrast is diminished, limiting diagnostic value. This study evaluated whether contrast media with an atomic number higher than iodine (high-Z) preserve vascular contrast using high VMI energy levels, thereby improving the accuracy of stenosis quantification. Methods: A phantom with 4 and 6 mm diameter rods to mimic small diameter vessels containing eccentric calcified plaques causing 25%, 50%, and 75% diameter stenoses was scanned with a dual-source PCD-CT system. Five different contrast media, including iodine, tungsten, holmium, hafnium, and bismuth, were tested. VMIs were reconstructed from 40 to 190 keV in 1-keV steps. Vessel attenuation, contrast-to-noise ratio (CNR), and stenoses were measured. Qualitative assessment of image quality was performed. Results: Iodine attenuation was high at lower VMI energy levels and dropped below 250 HU at >100 keV. Tungsten, holmium, hafnium, and bismuth maintained >250 HU attenuation throughout the entire energy range. Vessel CNR of iodine was high at lower and decreased at higher VMI energy levels, similar to the CNR of holmium and bismuth, though to a lesser extent. In distinction, CNRs of tungsten and hafnium were lower at lower VMI energy levels and increased to a relatively constant level at higher keV. Tungsten CNR increased with energy, approaching ~40 at high keV. Across all contrast media and stenosis degrees, stenoses were overestimated on low VMI energy levels (24% to 32.5% at 40 keV), while the degree of overestimation decreased at higher VMI energy levels (0% to 13.5% at 190 keV). At 190 keV, tungsten, hafnium, and bismuth showed ≤2.5% stenosis overestimation, compared with iodine (10% to 13.5%). Image quality varied between contrast media and energy levels: new very high-Z contrast media achieved higher scores, while iodine peaked at lower keV (55 to 70 keV) and, due to loss of contrast at higher energies, received the lowest overall scores. Conclusions: As compared with iodine, very high-Z contrast media enable superior lumen definition and more accurate stenosis assessment, also at high VMI energy levels, which minimize calcium blooming.
- 1 December 2025
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 61 (8) , 568-574
Open AccessHigh-Z Contrast Media for Coronary Photon-counting Detector CT Angiography
Background: Blooming artifacts from calcified plaques can obscure the vessel lumen, leading to overestimation of stenosis severity. Spectral coronary angiography with photon-counting detector CT (PCD-CT) provides virtual monoenergetic images (VMIs) for coronary artery disease assessment. While VMIs at high VMI energy levels reduce calcium blooming, iodine contrast is diminished, limiting diagnostic value. This study evaluated whether contrast media with an atomic number higher than iodine (high-Z) preserve vascular contrast using high VMI energy levels, thereby improving the accuracy of stenosis quantification. Methods: A phantom with 4 and 6 mm diameter rods to mimic small diameter vessels containing eccentric calcified plaques causing 25%, 50%, and 75% diameter stenoses was scanned with a dual-source PCD-CT system. Five different contrast media, including iodine, tungsten, holmium, hafnium, and bismuth, were tested. VMIs were reconstructed from 40 to 190 keV in 1-keV steps. Vessel attenuation, contrast-to-noise ratio (CNR), and stenoses were measured. Qualitative assessment of image quality was performed. Results: Iodine attenuation was high at lower VMI energy levels and dropped below 250 HU at >100 keV. Tungsten, holmium, hafnium, and bismuth maintained >250 HU attenuation throughout the entire energy range. Vessel CNR of iodine was high at lower and decreased at higher VMI energy levels, similar to the CNR of holmium and bismuth, though to a lesser extent. In distinction, CNRs of tungsten and hafnium were lower at lower VMI energy levels and increased to a relatively constant level at higher keV. Tungsten CNR increased with energy, approaching ~40 at high keV. Across all contrast media and stenosis degrees, stenoses were overestimated on low VMI energy levels (24% to 32.5% at 40 keV), while the degree of overestimation decreased at higher VMI energy levels (0% to 13.5% at 190 keV). At 190 keV, tungsten, hafnium, and bismuth showed ≤2.5% stenosis overestimation, compared with iodine (10% to 13.5%). Image quality varied between contrast media and energy levels: new very high-Z contrast media achieved higher scores, while iodine peaked at lower keV (55 to 70 keV) and, due to loss of contrast at higher energies, received the lowest overall scores. Conclusions: As compared with iodine, very high-Z contrast media enable superior lumen definition and more accurate stenosis assessment, also at high VMI energy levels, which minimize calcium blooming.
- Open Access
- 22 August 2025
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 61 (5) , 341-349
Deep Learning–based Automated Coronary Plaque Quantification
Objectives: The aim of this study was to evaluate the feasibility and reproducibility of a novel deep learning (DL)-based coronary plaque quantification tool with automatic case preparation in patients undergoing ultra-high resolution (UHR) photon-counting detector CT coronary angiography (CCTA), and to assess the influence of temporal resolution on plaque quantification. Materials and Methods: In this retrospective single-center study, 45 patients undergoing clinically indicated UHR CCTA were included. In each scan, 2 image data sets were reconstructed: one in the dual-source mode with 66 ms temporal resolution and one simulating a single-source mode with 125 ms temporal resolution. A novel, DL-based algorithm for fully automated coronary segmentation and intensity-based plaque quantification was applied to both data sets in each patient. Plaque volume quantification was performed at the vessel-level for the entire left anterior descending artery (LAD), left circumflex artery (CX), and right coronary artery (RCA), as well as at the lesion-level for the largest coronary plaque in each vessel. Diameter stenosis grade was quantified for the coronary lesion with the greatest longitudinal extent in each vessel. To assess reproducibility, the algorithm was rerun 3 times in 10 randomly selected patients, and all outputs were visually reviewed and confirmed by an expert reader. Paired Wilcoxon signed-rank tests with Benjamini-Hochberg correction were used for statistical comparisons. Results: One hundred nineteen out of 135 (88.1%) coronary arteries showed atherosclerotic plaques and were included in the analysis. In the reproducibility analysis, repeated runs of the algorithm yielded identical results across all plaque and lumen measurements ( P > 0.999). All outputs were confirmed to be anatomically correct, visually consistent, and did not require manual correction. At the vessel level, total plaque volumes were higher in the 125 ms reconstructions compared with the 66 ms reconstructions in 28 of 45 patients (62%), with both calcified and noncalcified plaque volumes being higher in 32 (71%) and 28 (62%) patients, respectively. Total plaque volumes in the LAD, CX, and RCA were significantly higher in the 125 ms reconstructions (681.3 vs. 647.8 mm 3 , P < 0.05). At the lesion level, total plaque volumes were higher in the 125 ms reconstructions in 44 of 45 patients (98%; 447.3 vs. 414.9 mm 3 , P < 0.001), with both calcified and noncalcified plaque volumes being higher in 42 of 45 patients (93%). The median diameter stenosis grades for all vessels were significantly higher in the 125 ms reconstructions (35.4% vs. 28.1%, P < 0.01). Conclusions: This study evaluated a novel DL-based tool with automatic case preparation for quantitative coronary plaque in UHR CCTA data sets. The algorithm was technically robust and reproducible, delivering anatomically consistent outputs not requiring manual correction. Reconstructions with lower temporal resolution (125 ms) systematically overestimated plaque burden compared with higher temporal resolution (66 ms), underscoring that protocol standardization is essential for reliable DL-based plaque quantification.
- 22 August 2025
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 61 (5) , 341-349
Open AccessDeep Learning–based Automated Coronary Plaque Quantification
Objectives: The aim of this study was to evaluate the feasibility and reproducibility of a novel deep learning (DL)-based coronary plaque quantification tool with automatic case preparation in patients undergoing ultra-high resolution (UHR) photon-counting detector CT coronary angiography (CCTA), and to assess the influence of temporal resolution on plaque quantification. Materials and Methods: In this retrospective single-center study, 45 patients undergoing clinically indicated UHR CCTA were included. In each scan, 2 image data sets were reconstructed: one in the dual-source mode with 66 ms temporal resolution and one simulating a single-source mode with 125 ms temporal resolution. A novel, DL-based algorithm for fully automated coronary segmentation and intensity-based plaque quantification was applied to both data sets in each patient. Plaque volume quantification was performed at the vessel-level for the entire left anterior descending artery (LAD), left circumflex artery (CX), and right coronary artery (RCA), as well as at the lesion-level for the largest coronary plaque in each vessel. Diameter stenosis grade was quantified for the coronary lesion with the greatest longitudinal extent in each vessel. To assess reproducibility, the algorithm was rerun 3 times in 10 randomly selected patients, and all outputs were visually reviewed and confirmed by an expert reader. Paired Wilcoxon signed-rank tests with Benjamini-Hochberg correction were used for statistical comparisons. Results: One hundred nineteen out of 135 (88.1%) coronary arteries showed atherosclerotic plaques and were included in the analysis. In the reproducibility analysis, repeated runs of the algorithm yielded identical results across all plaque and lumen measurements ( P > 0.999). All outputs were confirmed to be anatomically correct, visually consistent, and did not require manual correction. At the vessel level, total plaque volumes were higher in the 125 ms reconstructions compared with the 66 ms reconstructions in 28 of 45 patients (62%), with both calcified and noncalcified plaque volumes being higher in 32 (71%) and 28 (62%) patients, respectively. Total plaque volumes in the LAD, CX, and RCA were significantly higher in the 125 ms reconstructions (681.3 vs. 647.8 mm 3 , P < 0.05). At the lesion level, total plaque volumes were higher in the 125 ms reconstructions in 44 of 45 patients (98%; 447.3 vs. 414.9 mm 3 , P < 0.001), with both calcified and noncalcified plaque volumes being higher in 42 of 45 patients (93%). The median diameter stenosis grades for all vessels were significantly higher in the 125 ms reconstructions (35.4% vs. 28.1%, P < 0.01). Conclusions: This study evaluated a novel DL-based tool with automatic case preparation for quantitative coronary plaque in UHR CCTA data sets. The algorithm was technically robust and reproducible, delivering anatomically consistent outputs not requiring manual correction. Reconstructions with lower temporal resolution (125 ms) systematically overestimated plaque burden compared with higher temporal resolution (66 ms), underscoring that protocol standardization is essential for reliable DL-based plaque quantification.
- Open Access
- 25 April 2025
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 61 (1) , 32-40
Myocardial Late Enhancement With Photon-Counting Detector CT in Spontaneous Coronary Artery Dissection
Objectives: Spontaneous coronary artery dissection (SCAD) is a rare cause of acute coronary syndrome and myocardial infarction. Accurate diagnosis is crucial for appropriate management. This study aimed to compare late enhancement (LE) imaging using photon-counting detector (PCD)-CT with cardiac MRI in patients with SCAD in the acute phase and during follow-up and to introduce a novel approach for visualizing myocardial extracellular volume (ECV) distribution in the myocardium. Materials and Methods: This single-center prospective study enrolled patients with SCAD diagnosed with invasive coronary angiography. LE iodine imaging with spectral dual-source PCD-CT and cardiac MRI was performed early after symptom onset and at short-term follow-up. CT included coronary angiography and LE imaging (5 minutes after contrast). LE CT was assessed using the combination of conventional LE images, overlay images, polar maps, and with newly developed atlas maps. Atlas maps represent 2-dimensional maps with prefiltering applied to enable a simpler and more intuitive reading of ECV distribution across the myocardium. Cardiac MRI served as the reference standard for identifying pathologic myocardial segments based on late gadolinium enhancement (LGE) and edema on T2-weighted and T2-mapping images. Agreement between modalities was evaluated using Cohen's κ. Results: Seventeen patients (median age, 44 years [interquartile range, 36–52]; 11 women) underwent 24 LE CT and cardiac MRI scans. Sixteen patients (median age, 44 years; 10 women) underwent acute phase imaging (median 6 days after symptom onset), and 8 patients (median age, 45 years; 6 women) underwent follow-up imaging (median 120 days after symptom onset). Atlas maps were helpful in detecting segments with pathological ECV and to adjudicate corresponding myocardial segments. Agreement between LE CT with LGE cardiac MRI was strong in the acute phase (κ = 0.832), improving to almost perfect when comparing LE-CT with both LGE and edema in cardiac MRI (κ = 0.944). At follow-up imaging, agreement further improved as edema resolved (κ = 0.956). Conclusions: LE imaging with PCD-CT demonstrated strong agreement with cardiac MRI for detecting myocardial injury in SCAD, which further improved at follow-up when edema resolved. Newly introduced atlas maps proved useful for a simple and intuitive visualization of myocardial injury.
- 25 April 2025
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 61 (1) , 32-40
Open AccessMyocardial Late Enhancement With Photon-Counting Detector CT in Spontaneous Coronary Artery Dissection
Objectives: Spontaneous coronary artery dissection (SCAD) is a rare cause of acute coronary syndrome and myocardial infarction. Accurate diagnosis is crucial for appropriate management. This study aimed to compare late enhancement (LE) imaging using photon-counting detector (PCD)-CT with cardiac MRI in patients with SCAD in the acute phase and during follow-up and to introduce a novel approach for visualizing myocardial extracellular volume (ECV) distribution in the myocardium. Materials and Methods: This single-center prospective study enrolled patients with SCAD diagnosed with invasive coronary angiography. LE iodine imaging with spectral dual-source PCD-CT and cardiac MRI was performed early after symptom onset and at short-term follow-up. CT included coronary angiography and LE imaging (5 minutes after contrast). LE CT was assessed using the combination of conventional LE images, overlay images, polar maps, and with newly developed atlas maps. Atlas maps represent 2-dimensional maps with prefiltering applied to enable a simpler and more intuitive reading of ECV distribution across the myocardium. Cardiac MRI served as the reference standard for identifying pathologic myocardial segments based on late gadolinium enhancement (LGE) and edema on T2-weighted and T2-mapping images. Agreement between modalities was evaluated using Cohen's κ. Results: Seventeen patients (median age, 44 years [interquartile range, 36–52]; 11 women) underwent 24 LE CT and cardiac MRI scans. Sixteen patients (median age, 44 years; 10 women) underwent acute phase imaging (median 6 days after symptom onset), and 8 patients (median age, 45 years; 6 women) underwent follow-up imaging (median 120 days after symptom onset). Atlas maps were helpful in detecting segments with pathological ECV and to adjudicate corresponding myocardial segments. Agreement between LE CT with LGE cardiac MRI was strong in the acute phase (κ = 0.832), improving to almost perfect when comparing LE-CT with both LGE and edema in cardiac MRI (κ = 0.944). At follow-up imaging, agreement further improved as edema resolved (κ = 0.956). Conclusions: LE imaging with PCD-CT demonstrated strong agreement with cardiac MRI for detecting myocardial injury in SCAD, which further improved at follow-up when edema resolved. Newly introduced atlas maps proved useful for a simple and intuitive visualization of myocardial injury.
- Open Access
- 4 February 2025
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 60 (8) , 535-542
In Vivo Bone Mineral Density Assessment With Spectral Localizer Radiographs From Photon-Counting Detector CT
Purpose: The aim of this study was to determine in a prospective patient study the accuracy of areal bone mineral density (aBMD) measurements with spectral localizer radiographs obtained with a clinical photon-counting detector computed tomography (PCD-CT) scanner in comparison with dual-energy x-ray absorptiometry (DXA). Methods: In this institutional review board–approved, prospective study, 41 patients (15 females, 26 males; mean age 61.3 years, age range 35–78 years) underwent PCD-CT of the abdomen with a spectral localizer radiograph (tube voltage 140 kVp, tube current 30 mA) and DXA within a median of 45 days. aBMD values were derived for lumbar vertebrae L1–L4 from both methods and were compared with linear regression, Pearson correlation, intraclass correlation coefficients (ICCs), and Bland-Altman plots. T-scores were calculated on a patient level and were compared between methods. Results: DXA and spectral localizer radiographs showed strong correlation in aBMD measurements (R = 0.97, P < 0.001) and patient level T-scores (R = 0.99, P < 0.001). There was a strong agreement between aBMD from both methods (ICC, 0.96; 95% CI, 0.94–0.97). Bland-Altman analysis revealed a very small mean difference in aBMD between methods (mean absolute error 0.019 g/cm2) with narrow limits of agreement (−0.083 g/cm2 to 0.121 g/cm2). Similarly, there were small differences in regard to the T-score (mean absolute error 0.156) with narrow limits of agreement (−0.422 to 0.734) between methods. ICCs indicated an excellent agreement between T-scores from DXA and spectral localizer radiographs (ICC, 0.98; 95% confidence interval, 0.95–0.99). Conclusions: Our prospective patient study indicates that spectral localizer radiographs obtained with a clinical PCD-CT system enable accurate quantification of the lumbar bone areal mineral density. This opens up the opportunity for opportunistic screening of osteoporosis in patients who undergo CT for other indications.
- 4 February 2025
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 60 (8) , 535-542
Open AccessIn Vivo Bone Mineral Density Assessment With Spectral Localizer Radiographs From Photon-Counting Detector CT
Purpose: The aim of this study was to determine in a prospective patient study the accuracy of areal bone mineral density (aBMD) measurements with spectral localizer radiographs obtained with a clinical photon-counting detector computed tomography (PCD-CT) scanner in comparison with dual-energy x-ray absorptiometry (DXA). Methods: In this institutional review board–approved, prospective study, 41 patients (15 females, 26 males; mean age 61.3 years, age range 35–78 years) underwent PCD-CT of the abdomen with a spectral localizer radiograph (tube voltage 140 kVp, tube current 30 mA) and DXA within a median of 45 days. aBMD values were derived for lumbar vertebrae L1–L4 from both methods and were compared with linear regression, Pearson correlation, intraclass correlation coefficients (ICCs), and Bland-Altman plots. T-scores were calculated on a patient level and were compared between methods. Results: DXA and spectral localizer radiographs showed strong correlation in aBMD measurements (R = 0.97, P < 0.001) and patient level T-scores (R = 0.99, P < 0.001). There was a strong agreement between aBMD from both methods (ICC, 0.96; 95% CI, 0.94–0.97). Bland-Altman analysis revealed a very small mean difference in aBMD between methods (mean absolute error 0.019 g/cm2) with narrow limits of agreement (−0.083 g/cm2 to 0.121 g/cm2). Similarly, there were small differences in regard to the T-score (mean absolute error 0.156) with narrow limits of agreement (−0.422 to 0.734) between methods. ICCs indicated an excellent agreement between T-scores from DXA and spectral localizer radiographs (ICC, 0.98; 95% confidence interval, 0.95–0.99). Conclusions: Our prospective patient study indicates that spectral localizer radiographs obtained with a clinical PCD-CT system enable accurate quantification of the lumbar bone areal mineral density. This opens up the opportunity for opportunistic screening of osteoporosis in patients who undergo CT for other indications.
- Open Access
- 19 January 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (2) , 224
Relationship Between Myocardial Strain and Extracellular Volume: Exploratory Study in Patients with Severe Aortic Stenosis Undergoing Photon-Counting Detector CT
Background/Objectives: Diffuse myocardial fibrosis and altered deformation are relevant prognostic factors in aortic stenosis (AS) patients. The aim of this exploratory study was to investigate the relationship between myocardial strain, and myocardial extracellular volume (ECV) in patients with severe AS with a photon-counting detector (PCD)-CT. Methods: We retrospectively included 77 patients with severe AS undergoing PCD-CT imaging for transcatheter aortic valve replacement (TAVR) planning between January 2022 and May 2024 with a protocol including a non-contrast cardiac scan, an ECG-gated helical coronary CT angiography (CCTA), and a cardiac late enhancement scan. Myocardial strain was assessed with feature tracking from CCTA and ECV was calculated from spectral cardiac late enhancement scans. Results: Patients with cardiac amyloidosis (n = 4) exhibited significantly higher median mid-myocardial ECV (48.2% versus 25.5%, p = 0.048) but no significant differences in strain values (p > 0.05). Patients with prior myocardial infarction (n = 6) had reduced median global longitudinal strain values (−9.1% versus −21.7%, p < 0.001) but no significant differences in global mid-myocardial ECV (p > 0.05). Significant correlations were identified between the global longitudinal, circumferential, and radial strains and the CT-derived left ventricular ejection fraction (EF) (all, p < 0.001). Patients with low-flow, low-gradient AS and reduced EF exhibited lower median global longitudinal strain values compared with those with high-gradient AS (−15.2% versus −25.8%, p < 0.001). In these patients, the baso-apical mid-myocardial ECV gradient correlated with GLS values (R = 0.28, p = 0.02). Conclusions: In patients undergoing PCD-CT for TAVR planning, ECV and GLS may enable us to detect patients with cardiac amyloidosis and reduced myocardial contractility
- 19 January 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (2) , 224
Open AccessRelationship Between Myocardial Strain and Extracellular Volume: Exploratory Study in Patients with Severe Aortic Stenosis Undergoing Photon-Counting Detector CT
Background/Objectives: Diffuse myocardial fibrosis and altered deformation are relevant prognostic factors in aortic stenosis (AS) patients. The aim of this exploratory study was to investigate the relationship between myocardial strain, and myocardial extracellular volume (ECV) in patients with severe AS with a photon-counting detector (PCD)-CT. Methods: We retrospectively included 77 patients with severe AS undergoing PCD-CT imaging for transcatheter aortic valve replacement (TAVR) planning between January 2022 and May 2024 with a protocol including a non-contrast cardiac scan, an ECG-gated helical coronary CT angiography (CCTA), and a cardiac late enhancement scan. Myocardial strain was assessed with feature tracking from CCTA and ECV was calculated from spectral cardiac late enhancement scans. Results: Patients with cardiac amyloidosis (n = 4) exhibited significantly higher median mid-myocardial ECV (48.2% versus 25.5%, p = 0.048) but no significant differences in strain values (p > 0.05). Patients with prior myocardial infarction (n = 6) had reduced median global longitudinal strain values (−9.1% versus −21.7%, p < 0.001) but no significant differences in global mid-myocardial ECV (p > 0.05). Significant correlations were identified between the global longitudinal, circumferential, and radial strains and the CT-derived left ventricular ejection fraction (EF) (all, p < 0.001). Patients with low-flow, low-gradient AS and reduced EF exhibited lower median global longitudinal strain values compared with those with high-gradient AS (−15.2% versus −25.8%, p < 0.001). In these patients, the baso-apical mid-myocardial ECV gradient correlated with GLS values (R = 0.28, p = 0.02). Conclusions: In patients undergoing PCD-CT for TAVR planning, ECV and GLS may enable us to detect patients with cardiac amyloidosis and reduced myocardial contractility
- Open Access
- 25 March 2024
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 59 (10) , 677-683
Tungsten-Based Contrast Agent for Photon-Counting Detector CT Angiography in Calcified Coronaries
Objectives: Calcified plaques induce blooming artifacts in coronary computed tomography angiography (CCTA) potentially leading to inaccurate stenosis evaluation. Tungsten represents a high atomic number, experimental contrast agent with different physical properties than iodine. We explored the potential of a tungsten-based contrast agent for photon-counting detector (PCD) CCTA in heavily calcified coronary vessels. Materials and Methods: A cardiovascular phantom exhibiting coronaries with calcified plaques was imaged on a first-generation dual-source PCD-CT. The coronaries with 3 different calcified plaques were filled with iodine and tungsten contrast media solutions equating to iodine and tungsten delivery rates (IDR and TDR) of 0.3, 0.5, 0.7, 1.0, 1.5, 2.0, 2.5, and 3.0 g/s, respectively. Electrocardiogram-triggered sequential acquisitions were performed in the spectral mode (QuantumPlus). Virtual monoenergetic images (VMIs) were reconstructed from 40 to 190 keV in 1 keV increments. Blooming artifacts and percentage error stenoses from calcified plaques were quantified, and attenuation characteristics of both contrast media were recorded. Results: Blooming artifacts from calcified plaques were most pronounced at 40 keV (78%) and least pronounced at 190 keV (58%). Similarly, percentage error stenoses were highest at 40 keV (48%) and lowest at 190 keV (2%), respectively. Attenuation of iodine decreased monotonically in VMIs from low to high keV, with the strongest decrease from 40 keV to 100 keV (IDR of 2.5 g/s: 1279 HU at 40 keV, 187 HU at 100 kV, and 35 HU at 190 keV). The attenuation of tungsten, on the other hand, increased monotonically as a function of VMI energy, with the strongest increase between 40 and 100 keV (TDR of 2.5 g/s: 202 HU at 40 keV, 661 HU at 100 kV, and 717 HU at 190 keV). For each keV level, the relationship between attenuation and IDR/TDR could be described by linear regressions (R 2 ≥ 0.88, P < 0.001). Specifically, attenuation increased linearly when increasing the delivery rate irrespective of keV level or contrast medium. Iodine exhibited the highest relative increase in attenuation values at lower keV levels when increasing the IDR. Conversely, for tungsten, the greatest relative increase in attenuation values occurred at higher keV levels when increasing the TDR. When high keV imaging is desirable to reduce blooming artifacts from calcified plaques, IDR has to be increased at higher keV levels to maintain diagnostic vessel attenuation (ie, 300 HU), whereas for tungsten, TDR can be kept constant or can be even reduced at high keV energy levels. Conclusions: Tungsten's attenuation characteristics in relation to VMI energy levels are reversed to those of iodine, with tungsten exhibiting high attenuation values at high keV levels and vice versa. Thus, tungsten shows promise for high keV imaging CCTA with PCD-CT as—in distinction to iodine—both high vessel attenuation and low blooming artifacts from calcified plaques can be achieved.
- 25 March 2024
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 59 (10) , 677-683
Open AccessTungsten-Based Contrast Agent for Photon-Counting Detector CT Angiography in Calcified Coronaries
Objectives: Calcified plaques induce blooming artifacts in coronary computed tomography angiography (CCTA) potentially leading to inaccurate stenosis evaluation. Tungsten represents a high atomic number, experimental contrast agent with different physical properties than iodine. We explored the potential of a tungsten-based contrast agent for photon-counting detector (PCD) CCTA in heavily calcified coronary vessels. Materials and Methods: A cardiovascular phantom exhibiting coronaries with calcified plaques was imaged on a first-generation dual-source PCD-CT. The coronaries with 3 different calcified plaques were filled with iodine and tungsten contrast media solutions equating to iodine and tungsten delivery rates (IDR and TDR) of 0.3, 0.5, 0.7, 1.0, 1.5, 2.0, 2.5, and 3.0 g/s, respectively. Electrocardiogram-triggered sequential acquisitions were performed in the spectral mode (QuantumPlus). Virtual monoenergetic images (VMIs) were reconstructed from 40 to 190 keV in 1 keV increments. Blooming artifacts and percentage error stenoses from calcified plaques were quantified, and attenuation characteristics of both contrast media were recorded. Results: Blooming artifacts from calcified plaques were most pronounced at 40 keV (78%) and least pronounced at 190 keV (58%). Similarly, percentage error stenoses were highest at 40 keV (48%) and lowest at 190 keV (2%), respectively. Attenuation of iodine decreased monotonically in VMIs from low to high keV, with the strongest decrease from 40 keV to 100 keV (IDR of 2.5 g/s: 1279 HU at 40 keV, 187 HU at 100 kV, and 35 HU at 190 keV). The attenuation of tungsten, on the other hand, increased monotonically as a function of VMI energy, with the strongest increase between 40 and 100 keV (TDR of 2.5 g/s: 202 HU at 40 keV, 661 HU at 100 kV, and 717 HU at 190 keV). For each keV level, the relationship between attenuation and IDR/TDR could be described by linear regressions (R 2 ≥ 0.88, P < 0.001). Specifically, attenuation increased linearly when increasing the delivery rate irrespective of keV level or contrast medium. Iodine exhibited the highest relative increase in attenuation values at lower keV levels when increasing the IDR. Conversely, for tungsten, the greatest relative increase in attenuation values occurred at higher keV levels when increasing the TDR. When high keV imaging is desirable to reduce blooming artifacts from calcified plaques, IDR has to be increased at higher keV levels to maintain diagnostic vessel attenuation (ie, 300 HU), whereas for tungsten, TDR can be kept constant or can be even reduced at high keV energy levels. Conclusions: Tungsten's attenuation characteristics in relation to VMI energy levels are reversed to those of iodine, with tungsten exhibiting high attenuation values at high keV levels and vice versa. Thus, tungsten shows promise for high keV imaging CCTA with PCD-CT as—in distinction to iodine—both high vessel attenuation and low blooming artifacts from calcified plaques can be achieved.
- Open Access
- 30 January 2024
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 59 (9) , 622-628
A Novel Reconstruction Technique to Reduce Stair-Step Artifacts in Sequential Mode Coronary CT Angiography
Purpose: Prospective electrocardiography-triggering is one of the most commonly used cardiac computed tomography (CT) scan modes but can be susceptible to stair-step artifacts in the transition areas of an acquisition over multiple cardiac cycles. We evaluated a novel reconstruction algorithm to reduce the occurrence and severity of such artifacts in sequential coronary CT angiography. Materials and Methods: In this institutional review board–approved, retrospective study, 50 consecutive patients (16 females; mean age, 58.9 ± 15.2) were included who underwent coronary CT angiography on a dual-source photon-counting detector CT in the sequential ultra-high-resolution mode with a detector collimation of 120 × 0.2 mm. Each scan was reconstructed without (hereafter called standard reconstruction) and with the novel ZeeFree reconstruction algorithm, which aims to minimize stair-step artifacts. The presence and extent of stair-step artifacts were rated by 2 independent, blinded readers on a 4-point discrete visual scale. The relationship between the occurrences of artifacts was correlated with the average and variability of heart rate and with patient characteristics. Results: A total of 504 coronary segments were included into the analyses. In standard reconstructions, reader 1 reported stair-step artifacts in 40/504 (7.9%) segments, from which 12/504 led to nondiagnostic image quality (2.4% of all segments). Reader 2 reported 56/504 (11.1%) stair-step artifacts, from which 11/504 lead to nondiagnostic image quality (2.2% of all segments). With the ZeeFree algorithm, 9/12 (75%) and 8/11 (73%) of the nondiagnostic segments improved to a diagnostic quality for readers 1 and 2, respectively. The ZeeFree reconstruction algorithm significantly reduced the frequency and extent of stair-step artifacts compared with standard reconstructions for both readers (P < 0.001, each). Heart rate variability and body mass index were significantly related to the occurrence of stair-step artifacts (P < 0.05). Conclusions: Our study demonstrates the feasibility and effectiveness of a novel reconstruction algorithm leading to a significant reduction of stair-step artifacts and, hence, a reduction of coronary segments with a nondiagnostic image quality in sequential ultra-high-resolution coronary photon-counting detector CT angiography.
- 30 January 2024
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 59 (9) , 622-628
Open AccessA Novel Reconstruction Technique to Reduce Stair-Step Artifacts in Sequential Mode Coronary CT Angiography
Purpose: Prospective electrocardiography-triggering is one of the most commonly used cardiac computed tomography (CT) scan modes but can be susceptible to stair-step artifacts in the transition areas of an acquisition over multiple cardiac cycles. We evaluated a novel reconstruction algorithm to reduce the occurrence and severity of such artifacts in sequential coronary CT angiography. Materials and Methods: In this institutional review board–approved, retrospective study, 50 consecutive patients (16 females; mean age, 58.9 ± 15.2) were included who underwent coronary CT angiography on a dual-source photon-counting detector CT in the sequential ultra-high-resolution mode with a detector collimation of 120 × 0.2 mm. Each scan was reconstructed without (hereafter called standard reconstruction) and with the novel ZeeFree reconstruction algorithm, which aims to minimize stair-step artifacts. The presence and extent of stair-step artifacts were rated by 2 independent, blinded readers on a 4-point discrete visual scale. The relationship between the occurrences of artifacts was correlated with the average and variability of heart rate and with patient characteristics. Results: A total of 504 coronary segments were included into the analyses. In standard reconstructions, reader 1 reported stair-step artifacts in 40/504 (7.9%) segments, from which 12/504 led to nondiagnostic image quality (2.4% of all segments). Reader 2 reported 56/504 (11.1%) stair-step artifacts, from which 11/504 lead to nondiagnostic image quality (2.2% of all segments). With the ZeeFree algorithm, 9/12 (75%) and 8/11 (73%) of the nondiagnostic segments improved to a diagnostic quality for readers 1 and 2, respectively. The ZeeFree reconstruction algorithm significantly reduced the frequency and extent of stair-step artifacts compared with standard reconstructions for both readers (P < 0.001, each). Heart rate variability and body mass index were significantly related to the occurrence of stair-step artifacts (P < 0.05). Conclusions: Our study demonstrates the feasibility and effectiveness of a novel reconstruction algorithm leading to a significant reduction of stair-step artifacts and, hence, a reduction of coronary segments with a nondiagnostic image quality in sequential ultra-high-resolution coronary photon-counting detector CT angiography.