TAThomas Allmendinger

Thomas Allmendinger

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Thomas Allmendinger has a total of 30 co-authors. Here are the top co-authors by number of shared publications:

  • Hatem Alkadhi

    Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland

    5 shared publications
  • Bernhard Schmidt

    Siemens Healthcare GmbH, 91052 Erlangen, Germany

    4 shared publications
  • Matthias Eberhard

    Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland

    4 shared publications
  • Victor Mergen

    Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland

    4 shared publications
  • Lukas Jakob Moser

    From the Department of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland (L.J.M., K.M., V.M., M.E., T.F., H.A.); Department of Rheumatology, University Hospital Zurich, University of Zurich, Zurich, Switzerland (M.C.D.M., D.F., O.D.); Siemens Healthineers AG, Forchheim, Germany (T.N., B.S., T.F.); and Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, the Netherlands (T.F.).

    3 shared publications
  • Thomas Flohr

    Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich , 8091 Zurich

    3 shared publications

Latest Publications

  • Open Access

    High-Z Contrast Media for Coronary Photon-counting Detector CT Angiography

    by Tristan T. Demmert, Konstantin Klambauer, Bernhard Schmidt, Victor Mergen, Lukas J. Moser, Philipp N. Maintz, Thomas Allmendinger, Thomas Flohr, Hubertus Pietsch, Matthias Eberhard, et al.

    Background: Blooming artifacts from calcified plaques can obscure the vessel lumen, leading to overestimation of stenosis severity. Spectral coronary angiography with photon-counting detector CT (PCD-CT) provides virtual monoenergetic images (VMIs) for coronary artery disease assessment. While VMIs at high VMI energy levels reduce calcium blooming, iodine contrast is diminished, limiting diagnostic value. This study evaluated whether contrast media with an atomic number higher than iodine (high-Z) preserve vascular contrast using high VMI energy levels, thereby improving the accuracy of stenosis quantification. Methods: A phantom with 4 and 6 mm diameter rods to mimic small diameter vessels containing eccentric calcified plaques causing 25%, 50%, and 75% diameter stenoses was scanned with a dual-source PCD-CT system. Five different contrast media, including iodine, tungsten, holmium, hafnium, and bismuth, were tested. VMIs were reconstructed from 40 to 190 keV in 1-keV steps. Vessel attenuation, contrast-to-noise ratio (CNR), and stenoses were measured. Qualitative assessment of image quality was performed. Results: Iodine attenuation was high at lower VMI energy levels and dropped below 250 HU at >100 keV. Tungsten, holmium, hafnium, and bismuth maintained >250 HU attenuation throughout the entire energy range. Vessel CNR of iodine was high at lower and decreased at higher VMI energy levels, similar to the CNR of holmium and bismuth, though to a lesser extent. In distinction, CNRs of tungsten and hafnium were lower at lower VMI energy levels and increased to a relatively constant level at higher keV. Tungsten CNR increased with energy, approaching ~40 at high keV. Across all contrast media and stenosis degrees, stenoses were overestimated on low VMI energy levels (24% to 32.5% at 40 keV), while the degree of overestimation decreased at higher VMI energy levels (0% to 13.5% at 190 keV). At 190 keV, tungsten, hafnium, and bismuth showed ≤2.5% stenosis overestimation, compared with iodine (10% to 13.5%). Image quality varied between contrast media and energy levels: new very high-Z contrast media achieved higher scores, while iodine peaked at lower keV (55 to 70 keV) and, due to loss of contrast at higher energies, received the lowest overall scores. Conclusions: As compared with iodine, very high-Z contrast media enable superior lumen definition and more accurate stenosis assessment, also at high VMI energy levels, which minimize calcium blooming.


  • Open Access

    Deep Learning–based Automated Coronary Plaque Quantification

    by Konstantin Klambauer, Silvan Daniel Burger, Tristan Thorben Demmert, Victor Mergen, Lukas Jakob Moser, Mehmet Akif Gulsun, Max Schöbinger, Chris Schwemmer, Michael Wels, Thomas Allmendinger, et al.

    Objectives: The aim of this study was to evaluate the feasibility and reproducibility of a novel deep learning (DL)-based coronary plaque quantification tool with automatic case preparation in patients undergoing ultra-high resolution (UHR) photon-counting detector CT coronary angiography (CCTA), and to assess the influence of temporal resolution on plaque quantification. Materials and Methods: In this retrospective single-center study, 45 patients undergoing clinically indicated UHR CCTA were included. In each scan, 2 image data sets were reconstructed: one in the dual-source mode with 66 ms temporal resolution and one simulating a single-source mode with 125 ms temporal resolution. A novel, DL-based algorithm for fully automated coronary segmentation and intensity-based plaque quantification was applied to both data sets in each patient. Plaque volume quantification was performed at the vessel-level for the entire left anterior descending artery (LAD), left circumflex artery (CX), and right coronary artery (RCA), as well as at the lesion-level for the largest coronary plaque in each vessel. Diameter stenosis grade was quantified for the coronary lesion with the greatest longitudinal extent in each vessel. To assess reproducibility, the algorithm was rerun 3 times in 10 randomly selected patients, and all outputs were visually reviewed and confirmed by an expert reader. Paired Wilcoxon signed-rank tests with Benjamini-Hochberg correction were used for statistical comparisons. Results: One hundred nineteen out of 135 (88.1%) coronary arteries showed atherosclerotic plaques and were included in the analysis. In the reproducibility analysis, repeated runs of the algorithm yielded identical results across all plaque and lumen measurements ( P > 0.999). All outputs were confirmed to be anatomically correct, visually consistent, and did not require manual correction. At the vessel level, total plaque volumes were higher in the 125 ms reconstructions compared with the 66 ms reconstructions in 28 of 45 patients (62%), with both calcified and noncalcified plaque volumes being higher in 32 (71%) and 28 (62%) patients, respectively. Total plaque volumes in the LAD, CX, and RCA were significantly higher in the 125 ms reconstructions (681.3 vs. 647.8 mm 3 , P < 0.05). At the lesion level, total plaque volumes were higher in the 125 ms reconstructions in 44 of 45 patients (98%; 447.3 vs. 414.9 mm 3 , P < 0.001), with both calcified and noncalcified plaque volumes being higher in 42 of 45 patients (93%). The median diameter stenosis grades for all vessels were significantly higher in the 125 ms reconstructions (35.4% vs. 28.1%, P < 0.01). Conclusions: This study evaluated a novel DL-based tool with automatic case preparation for quantitative coronary plaque in UHR CCTA data sets. The algorithm was technically robust and reproducible, delivering anatomically consistent outputs not requiring manual correction. Reconstructions with lower temporal resolution (125 ms) systematically overestimated plaque burden compared with higher temporal resolution (66 ms), underscoring that protocol standardization is essential for reliable DL-based plaque quantification.


  • Open Access

    A Novel Reconstruction Technique to Reduce Stair-Step Artifacts in Sequential Mode Coronary CT Angiography

    by Lukas Jakob Moser, Victor Mergen, Thomas Allmendinger, Robert Manka, Matthias Eberhard, Hatem Alkadhi

    Purpose: Prospective electrocardiography-triggering is one of the most commonly used cardiac computed tomography (CT) scan modes but can be susceptible to stair-step artifacts in the transition areas of an acquisition over multiple cardiac cycles. We evaluated a novel reconstruction algorithm to reduce the occurrence and severity of such artifacts in sequential coronary CT angiography. Materials and Methods: In this institutional review board–approved, retrospective study, 50 consecutive patients (16 females; mean age, 58.9 ± 15.2) were included who underwent coronary CT angiography on a dual-source photon-counting detector CT in the sequential ultra-high-resolution mode with a detector collimation of 120 × 0.2 mm. Each scan was reconstructed without (hereafter called standard reconstruction) and with the novel ZeeFree reconstruction algorithm, which aims to minimize stair-step artifacts. The presence and extent of stair-step artifacts were rated by 2 independent, blinded readers on a 4-point discrete visual scale. The relationship between the occurrences of artifacts was correlated with the average and variability of heart rate and with patient characteristics. Results: A total of 504 coronary segments were included into the analyses. In standard reconstructions, reader 1 reported stair-step artifacts in 40/504 (7.9%) segments, from which 12/504 led to nondiagnostic image quality (2.4% of all segments). Reader 2 reported 56/504 (11.1%) stair-step artifacts, from which 11/504 lead to nondiagnostic image quality (2.2% of all segments). With the ZeeFree algorithm, 9/12 (75%) and 8/11 (73%) of the nondiagnostic segments improved to a diagnostic quality for readers 1 and 2, respectively. The ZeeFree reconstruction algorithm significantly reduced the frequency and extent of stair-step artifacts compared with standard reconstructions for both readers (P < 0.001, each). Heart rate variability and body mass index were significantly related to the occurrence of stair-step artifacts (P < 0.05). Conclusions: Our study demonstrates the feasibility and effectiveness of a novel reconstruction algorithm leading to a significant reduction of stair-step artifacts and, hence, a reduction of coronary segments with a nondiagnostic image quality in sequential ultra-high-resolution coronary photon-counting detector CT angiography.


  • Ultra-high resolution photon-counting coronary CT angiography improves coronary stenosis quantification over a wide range of heart rates – A dynamic phantom study

    by Emese Zsarnoczay, Nicola Fink, U. Joseph Schoepf, Jim O'DOherty, Thomas Allmendinger, Junia Hagenauer, Elias V. Wolf, Joseph P. Griffith, Pál Maurovich-Horvat, Akos Varga-Szemes, et al.


  • Top Cited Papers
    Open Access

    Photon-Counting Detector CT-Based Vascular Calcium Removal Algorithm

    by Thomas Allmendinger, Tristan Nowak, Thomas Flohr, Ernst Dipl Phys Klotz, Junia Cand. Med. Hagenauer, Hatem Md Alkadhi, Bernhard Schmidt

    Objectives: The diagnostic performance of coronary computed tomography angiography is known to be negatively affected by the presence of severely calcified plaques in the coronary arteries. In this article, the performance of a novel image reconstruction algorithm (PureLumen) based on spectral CT data of a first-generation dual-source photon-counting detector computed tomography (PCD-CT) system was assessed in a phantom study. PureLumen tries to remove only the calcified contributions from the image while leaving the rest unmodified. Materials and Methods: The study uses 2 iodine contrast filled vessel phantoms (diameter 4 mm) filled with different concentrations of iodine and equipped with calcified stenosis inserts. Each phantom features 2 separate calcified lesions of 25% and 50% percentage diameter stenosis (PDS) size. The vessel phantoms were mounted inside an anthropomorphic thorax phantom attached to an artificial motion device, simulating realistic cardiac motion at heart rates between 50 beats per minute and 100 beats per minute. Acquisitions were performed using a prospectively electrocardiogram triggered dual-source sequence mode on a PCD-CT system (NAEOTOM Alpha, Siemens Healthineers). Images were reconstructed at 80% of the RR interval with virtual monoenergetic images (Mono) and with additional calcium-removal (PureLumen), both at 65 keV. PureLumen is based on a spectral base material decomposition into iodine and calcium, which aims to reconstruct images without calcium contributions, while leaving all other material contribution unchanged. Stenosis grade was assessed individually for each vessel insert in all reconstructed image series by 2 readers. Results: The measured median PDS values for the 50% lesion were 56.0% (52.0%, 57.0%) for the Mono case and 50.0% (48.5%, 51.0%) for PureLumen. The 25% lesion median PDS values were 36.0% (29.5%, 39.5%) for Mono and 31.5% (30.5%, 34.0%) for PureLumen. Both lesion sizes demonstrate a significant difference between Mono and PureLumen in their result (P < 0.05) with PureLumen median values being closer to the actual true stenosis size for the 50% and 25% lesion. A visual assessment of the image quality depending on the heart rate yielded good image quality up to a heart rate of 80 beats per minute in the PureLumen case. Conclusions: This phantom study shows that a novel calcium-removal image reconstruction algorithm (PureLumen) using a first-generation dual-source PCD-CT effectively decreases blooming artifacts caused by heavily calcified plaques and improves image interpretability. It also shows that PureLumen retains its performance in the presence of motion with simulated heart rates up to 80 beats per minute. Future in vivo clinical studies are needed to confirm the benefits of this type of reconstruction in terms of coronary computed tomography angiography quality and accuracy.


  • Open Access

    Cardiac CT – Today & Tomorrow

    by Thomas Allmendinger

    A brief overview of Cardiac CT - Today & Tomorrow from a Siemens Healthineers perspective

  • Open Access

    Coronary Calcium Scoring with First Generation Dual-Source Photon-Counting CT—First Evidence from Phantom and In-Vivo Scans

    by Matthias Eberhard, Victor Mergen, Kai Higashigaito, Thomas Allmendinger, Robert Manka, Thomas Flohr, Bernhard Schmidt, Andre Euler, Hatem Alkadhi

    We evaluated the accuracy of coronary artery calcium (CAC) scoring on a dual-source photon-counting detector CT (PCD-CT). An anthropomorphic chest phantom underwent ECG-gated sequential scanning on a PCD-CT at 120 kV with four radiation dose levels (CTDIvol, 2.0–8.6 mGy). Polychromatic images at 120 kV (T3D) and virtual monoenergetic images (VMI), from 60 to 75 keV without quantum iterative reconstruction (no QIR) and QIR strength levels 1–4, were reconstructed. For reference, the same phantom was scanned on a conventional energy-integrating detector CT (120 kV; filtered back projection) at identical radiation doses. CAC scoring in 20 patients with PCD-CT (120 kV; no QIR and QIR 1–4) were included. In the phantom, there were no differences between CAC scores of different radiation doses (all, p > 0.05). Images with 70 keV, no QIR (CAC score, 649); 65 keV, QIR 3 (656); 65 keV; QIR4 (648) and T3D, QIR4 (656) showed a p < 0.001) and for each 5 keV-increase (all, p < 0.001). Patient data (median CAC score: 86 [inter-quartile range: 38–978] at 70 keV) confirmed relationships and differences between reconstructions from the phantom. First phantom and in-vivo experience with a clinical dual-source PCD-CT system shows accurate CAC scoring with VMI reconstructions at different radiation dose levels.