Xin Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xin Wang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Guoxing Wang
Shanghai Jiao Tong University
1 shared publication - Shihong Zhou
Department of Micro-Nano Electronics, Shanghai Jiao Tong University, Shanghai, China
1 shared publication Xiao Han
Department of Micro-Nano Electronics, Shanghai Jiao Tong University, Shanghai, China
1 shared publication- Yang Zhao
School of Integrated Circuits, Shanghai Jiao Tong University, Shanghai, China
1 shared publication - Yanxing Suo
Shanghai Jiao Tong University
1 shared publication
Latest Publications
- Open Access
- 1 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Integrated Circuits and Systems
- Vol. 1 (4) , 239-246
A Multi-Channel 133-dB DR PPG/ECG SoC for Smart Wearable Devices
Real-time monitoring of multimodal vital signs including electrocardiography (ECG) and photoplethysmography (PPG) on wearable devices are attracting increasing interests. Motion artifacts, ambient light interference and sensor-skin contact variability affect signal quality significantly, demanding a multi-channel sensor interface chip with high dynamic range yet low power. A PPG/ECG interface chip is proposed for robust signal optimization. Time-division multiplexing, ambient double sampling and DC current compensation together enhance the dynamic range. Fabricated in a 0.18μm process, the chip features a 5.63-pArms direct digitized input-referred noise for PPG readout and 365-nVrms for ECG. A cross-scale dynamic range of 133dB is achieved, providing saturation-free usage for sport wearable devices such as smart watches and rings.
- 1 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Integrated Circuits and Systems
- Vol. 1 (4) , 239-246
Open AccessA Multi-Channel 133-dB DR PPG/ECG SoC for Smart Wearable Devices
Real-time monitoring of multimodal vital signs including electrocardiography (ECG) and photoplethysmography (PPG) on wearable devices are attracting increasing interests. Motion artifacts, ambient light interference and sensor-skin contact variability affect signal quality significantly, demanding a multi-channel sensor interface chip with high dynamic range yet low power. A PPG/ECG interface chip is proposed for robust signal optimization. Time-division multiplexing, ambient double sampling and DC current compensation together enhance the dynamic range. Fabricated in a 0.18μm process, the chip features a 5.63-pArms direct digitized input-referred noise for PPG readout and 365-nVrms for ECG. A cross-scale dynamic range of 133dB is achieved, providing saturation-free usage for sport wearable devices such as smart watches and rings.