TTToshiro Tsubouchi

Toshiro Tsubouchi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Toshiro Tsubouchi has a total of 12 co-authors. Here are the top co-authors by number of shared publications:

  • Masaaki Takashina

    Department of Medical Physics, Osaka Heavy Ion Therapy Center, Otemae, Chuo-ku, Osaka, Osaka, 5400008, JAPAN

    3 shared publications
  • Masashi Yagi

    National Cancer Centre Singapore

    3 shared publications
  • Misato Umemura

    Department of Medical Physics and Engineering, The University of Osaka Graduate School of Medicine Faculty of Medicine, 1-1 Yamadaoka, Suita, Osaka Prefecture, 5650871, JAPAN

    3 shared publications
  • Naoto Saruwatari

    Department of Medical Physics and Engineering, The University of Osaka Graduate School of Medicine Faculty of Medicine, 1-1 Yamadaoka, Suita, Osaka Prefecture, 5650871, JAPAN

    3 shared publications
  • Tatsuaki Kanai

    Division of Health Science, The University of Osaka Graduate School of Medicine Faculty of Medicine, 1-1 Yamadaoka, Suita, Osaka Prefecture, 5650871, JAPAN

    3 shared publications
  • Kazumasa Minami

    Division of Health Science, The University of Osaka Graduate School of Medicine Faculty of Medicine, 1-1 Yamadaoka, Suita, Osaka Prefecture, 5650871, JAPAN

    2 shared publications

Latest Publications

  • Open Access

    Quantifying biological effects of spatially heterogeneous carbon ion dose distributions using EUD

    by Toshiro Tsubouchi, Misato Umemura, Kazumasa Minami, Naoto Saruwatari, Noriaki Hamatani, Masaaki Takashina, Masashi Yagi, Tatsuaki Kanai

    This study aimed to experimentally investigate the cell survival responses of tumor and normal cell lines to spatially heterogeneous carbon ion dose distributions with varying peak-to-valley dose ratios (PVDRs) and linear energy transfer (LET) conditions, and to assess the utility of equivalent uniform dose (EUD) as a quantitative metric for analyzing these responses. HSGc-C5 (tumor) and Nuli-1 (normal tissue) cell lines were irradiated using carbon ion beams with different spatial dose patterns (Grid, Frame, Half) and two PVDR levels under low LET conditions (~10 keV μm −1 ). Additionally, high LET (~50 keV μm −1 ) Spread Out Bragg Peak (SOBP) Grid patterns were used for the HSGc-C5 cells. Clonogenic survival assays were performed to evaluate biological response. Survival data were analyzed both as a function of delivered physical dose and EUD, calculated using an LQ model–based formulation. Tumor cells exhibited enhanced cytotoxic effects under high LET and high PVDR conditions (the dose required to reach SF = 0.1 was approximately 40% lower at PVDR = 4.0 and 10% lower at PVDR = 1.64 compared with the simulation results), whereas normal cells showed a slight sparing effect under low LET irradiation. Even at the same total dose and PVDR, different spatial dose patterns produced measurable differences in survival, underscoring the impact of spatial heterogeneity. EUD-based analysis further enabled quantitative comparison between heterogeneous and uniform dose distributions. These findings indicate that spatial dose heterogeneity and LET can be leveraged to enhance tumor control while reducing normal tissue damage in carbon ion therapy. The EUD approach may offer a practical tool for treatment plan evaluation in spatially modulated particle therapy.

  • Quantitative Assessment of Delivered Dose in Carbon Ion Spatially Fractionated Radiotherapy (C-SFRT) and Biological Response to C-SFRT

    by Toshiro Tsubouchi, Misato Umemura, Kazumasa Minami, Noriaki Hamatani, Naoto Saruwatari, Masaaki Takashina, Masashi Yagi, Keith M Furutani, Shinichi Shimizu, Tatsuaki Kanai

    Objective Applying carbon ion beams, which have high linear energy transfer and low scatter within the human body, to Spatially Fractionated Radiation Therapy (SFRT) could benefit the treatment of deep-seated or radioresistant tumors. This study aims to simulate the dose distributions of spatially fractionated beams (SFB) to accurately determine the delivered dose and model the cell survival rate following SFB irradiation. Approach Dose distributions of carbon ion beams are calculated using the Triple Gaussian Model. The sensitive volume of the detector used in measurements was also considered. If the measurements and simulations show good agreement, the dose distribution and absolute dose delivered by SFB can be accurately estimated. Three types of dose distributions were delivered to human salivary gland cells (HSGc-C5): uniform dose distribution (UDD), and one-dimensional (1D) grid-like dose distributions (GDD) with 6 mm and 8 mm spacing. These provided high (Peak-to-Valley Dose Ratio, PVDR=4.0) and low (PVDR=1.64) dose differences between peak and valley doses, respectively. Linear-Quadratic (LQ) model parameters for HSGc-C5 were derived from the UDD and cell survival fractions (SF) were simulated for 1D GDD using these values. Main results Good agreement was observed between measurements and simulations when accounting for detector volume. However, the TPS results overestimated dose in steep gradient region, likely due to the 2.0 mm calculation grid size. LQ parameters for HSGc-C5 were α = 0.34 and β = 0.057. The 1D GDD with 6 mm spacing showed good agreement between simulations and experiments, but the 8.0 mm spacing resulted in lower experimental cell survival. Significance We successfully simulated grid-like dose distributions and conducted SF simulations. The results suggest potential cell-killing effects due to high-dose differences in SFB.


  • Quantitative Assessment of Delivered Dose in Carbon Ion Spatially Fractionated Radiotherapy (C-SFRT) and Biological Response to C-SFRT

    by Toshiro Tsubouchi, Misato Umemura, Kazumasa Minami, Noriaki Hamatani, Naoto Saruwatari, Masaaki Takashina, Masashi Yagi, Keith M Furutani, Shinichi Shimizu, Tatsuaki Kanai

    Objective Applying carbon ion beams, which have high linear energy transfer and low scatter within the human body, to Spatially Fractionated Radiation Therapy (SFRT) could benefit the treatment of deep-seated or radioresistant tumors. This study aims to simulate the dose distributions of spatially fractionated beams (SFB) to accurately determine the delivered dose and model the cell survival rate following SFB irradiation. Approach Dose distributions of carbon ion beams are calculated using the Triple Gaussian Model. The sensitive volume of the detector used in measurements was also considered. If the measurements and simulations show good agreement, the dose distribution and absolute dose delivered by SFB can be accurately estimated. Three types of dose distributions were delivered to human salivary gland cells (HSGc-C5): uniform dose distribution (UDD), and one-dimensional (1D) grid-like dose distributions (GDD) with 6 mm and 8 mm spacing. These provided high (Peak-to-Valley Dose Ratio, PVDR=4.0) and low (PVDR=1.64) dose differences between peak and valley doses, respectively. Linear-Quadratic (LQ) model parameters for HSGc-C5 were derived from the UDD and cell survival fractions (SF) were simulated for 1D GDD using these values. Main results Good agreement was observed between measurements and simulations when accounting for detector volume. However, the TPS results overestimated dose in steep gradient region, likely due to the 2.0 mm calculation grid size. LQ parameters for HSGc-C5 were α = 0.34 and β = 0.057. The 1D GDD with 6 mm spacing showed good agreement between simulations and experiments, but the 8.0 mm spacing resulted in lower experimental cell survival. Significance We successfully simulated grid-like dose distributions and conducted SF simulations. The results suggest potential cell-killing effects due to high-dose differences in SFB.