Wanderson Santos de Jesus
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wanderson Santos de Jesus has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- José Renato de Castro Pessôa
Graduate Program in Science, Innovation and Modeling in Materials (PROCIMM), Department of Engineering and Computing, State University of Santa Cruz (UESC), Ilhéus 45662-900, BA, Brazil
3 shared publications - Laio Andrade Sacramento
Department of Engineering and Computing, State University of Santa Cruz (UESC), Ilhéus 45662-900, BA, Brazil
3 shared publications - Suânia Fabiele Moitinho da Silva
Graduate Program in Science, Innovation and Modeling in Materials (PROCIMM), Department of Engineering and Computing, State University of Santa Cruz (UESC), Ilhéus 45662-900, BA, Brazil
3 shared publications - Thalles Murilo Santos de Almeida
Graduate Program in Science, Innovation and Modeling in Materials (PROCIMM), Department of Engineering and Computing, State University of Santa Cruz (UESC), Ilhéus 45662-900, BA, Brazil
3 shared publications - Eduarda Silva Leal
Department of Agrarian and Environmental Sciences (DCAA), State University of Santa Cruz (UESC), Ilhéus 45662-900, BA, Brazil
2 shared publications - Ivan Bezerra Allaman
Department of Exact Sciences, State University of Santa Cruz (UESC), Ilhéus 45662-900, BA, Brazil
2 shared publications
Latest Publications
- Open Access
- 31 July 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (15) , 8495
Impact of Fiber Type on Chloride Ingress in Concrete: A MacroXRF Imaging Analysis
Chloride ion penetration is one of the most aggressive threats to reinforced concrete, as it triggers the electrochemical corrosion of steel reinforcement, compromising structural integrity and durability. Chloride ingress occurs through the porous structure of concrete, making permeability control crucial for enhancing structural longevity. Fiber-reinforced concrete (FRC) is widely used to improve durability; however, the effects of different fiber types on chloride resistance remain unclear. This study examines the influence of glass and polypropylene fibers on concrete’s microstructure and chloride penetration resistance. Cylindrical specimens were prepared, including a reference mix without fibers and mixes with 0.25% and 0.50% fiber content by volume. Both fiber types were tested for chloride resistance. The accelerated non-steady-state migration method was employed to determine the resistance coefficients to chloride ion penetration, while X-ray macrofluorescence (MacroXRF) mapped the chlorine infiltration depth in the samples. Compressive strength decreased in all fiber-reinforced samples, with 0.50% glass fiber leading to a 56% reduction in strength. Nevertheless, the XRF results showed that a 0.25% fiber content significantly reduced chloride penetration, with polypropylene fibers outperforming glass fibers. These findings highlight the critical role of fiber type and volume in improving concrete durability, offering insights for designing long-lasting FRC structures in chloride-rich environments.
- 31 July 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (15) , 8495
Open AccessImpact of Fiber Type on Chloride Ingress in Concrete: A MacroXRF Imaging Analysis
Chloride ion penetration is one of the most aggressive threats to reinforced concrete, as it triggers the electrochemical corrosion of steel reinforcement, compromising structural integrity and durability. Chloride ingress occurs through the porous structure of concrete, making permeability control crucial for enhancing structural longevity. Fiber-reinforced concrete (FRC) is widely used to improve durability; however, the effects of different fiber types on chloride resistance remain unclear. This study examines the influence of glass and polypropylene fibers on concrete’s microstructure and chloride penetration resistance. Cylindrical specimens were prepared, including a reference mix without fibers and mixes with 0.25% and 0.50% fiber content by volume. Both fiber types were tested for chloride resistance. The accelerated non-steady-state migration method was employed to determine the resistance coefficients to chloride ion penetration, while X-ray macrofluorescence (MacroXRF) mapped the chlorine infiltration depth in the samples. Compressive strength decreased in all fiber-reinforced samples, with 0.50% glass fiber leading to a 56% reduction in strength. Nevertheless, the XRF results showed that a 0.25% fiber content significantly reduced chloride penetration, with polypropylene fibers outperforming glass fibers. These findings highlight the critical role of fiber type and volume in improving concrete durability, offering insights for designing long-lasting FRC structures in chloride-rich environments.
- Open Access
- 26 February 2025
- Published by MDPI AG in Journal of Composites Science
- Vol. 9 (3) , 110
Leveraging Delayed Strength Gains in Supplementary Cementitious Material Concretes: Rethinking Mix Design for Enhanced Cost Efficiency and Sustainability
Engineers commonly use the 28-day characteristic strength of concrete for project calculations, but this may not reflect the full-strength potential, especially in concretes with supplementary cementitious materials (SCMs). SCMs, known for their slow reactivity, often delay optimal strength beyond 28 days, requiring higher cement content to speed up early strength development, thus increasing production costs. This study examined the relationship between concrete age and mechanical strength across eight cement types, including tests for axial compression, water absorption, void index, and specific mass. The findings showed that pozzolan and slag cements gained significant long-term strength due to slow pozzolanic reactions. Conversely, limestone filler mixes had lower initial strength and slower progress, likely due to increased porosity from fine fillers. A correlation was found between higher pozzolan content and improved durability, including reduced water absorption and void index. Cost analysis indicated that optimizing cement mix designs for targeted strength levels could reduce production costs, especially for concretes with high SCM content. Using long-term characteristic strength rather than the traditional 28-day strength resulted in approximately 14% savings, particularly for slag- and pozzolan-based cements. The savings were less significant for other cement types, emphasizing the importance of adjusting mix designs based on both performance and financial considerations.
- 26 February 2025
- Published by MDPI AG in Journal of Composites Science
- Vol. 9 (3) , 110
Open AccessLeveraging Delayed Strength Gains in Supplementary Cementitious Material Concretes: Rethinking Mix Design for Enhanced Cost Efficiency and Sustainability
Engineers commonly use the 28-day characteristic strength of concrete for project calculations, but this may not reflect the full-strength potential, especially in concretes with supplementary cementitious materials (SCMs). SCMs, known for their slow reactivity, often delay optimal strength beyond 28 days, requiring higher cement content to speed up early strength development, thus increasing production costs. This study examined the relationship between concrete age and mechanical strength across eight cement types, including tests for axial compression, water absorption, void index, and specific mass. The findings showed that pozzolan and slag cements gained significant long-term strength due to slow pozzolanic reactions. Conversely, limestone filler mixes had lower initial strength and slower progress, likely due to increased porosity from fine fillers. A correlation was found between higher pozzolan content and improved durability, including reduced water absorption and void index. Cost analysis indicated that optimizing cement mix designs for targeted strength levels could reduce production costs, especially for concretes with high SCM content. Using long-term characteristic strength rather than the traditional 28-day strength resulted in approximately 14% savings, particularly for slag- and pozzolan-based cements. The savings were less significant for other cement types, emphasizing the importance of adjusting mix designs based on both performance and financial considerations.
- Open Access
Comparative Study of ASTM C1202 and IBRACON/NT Build 492 Testing Methods for Assessing Chloride Ion Penetration in Concretes Using Different Types of Cement
Durability is crucial for reinforced concrete, directly influencing the service life of structures. The presence of aggressive agents, especially chloride ions, significantly impacts durability. This study investigates the differences between ASTM C1202 and IBRACON/NT Build 492 standards in concrete containing various types of cement designed for a characteristic compressive strength of 40 MPa. Forty-eight cylindrical samples were prepared using eight types of Portland cement, including those with blast furnace slag, filler, and pozzolanic materials. Chloride migration tests were performed according to the ASTM C1202/2022 and IBRACON/NT Build 492/1999 methodologies. At a 95% confidence level, the results indicated that concrete made with filler-containing cement (PCII F-SR and PC II F) showed the poorest chloride resistance, with charge passing values exceeding 4000 coulombs (ASTM C1202) and diffusion coefficients above 10 × 10−12 m2/s (IBRACON/NT Build 492). In contrast, concrete containing high slag cement (PC III-SR) and pozzolan cement (PC IV) demonstrated superior resistance to chloride penetration, with charge passing values below 1500 coulombs and diffusion coefficients under 5 × 10−12 m2/s. Notably, discrepancies in classification were observed, as PC II Z (fly-ash based) and PC II E-SR (slag-based) received different ratings under the two methods. ASTM C1202 was found to be more stringent than NT Build 492, highlighting significant variations in the classification criteria between these standards. Based on the findings, new interval values are proposed for classifying concrete regarding the risk of chloride ion penetration, particularly for the ASTM C1202 standard, in order to better align with performance-based durability criteria and improve classification accuracy.
Open AccessComparative Study of ASTM C1202 and IBRACON/NT Build 492 Testing Methods for Assessing Chloride Ion Penetration in Concretes Using Different Types of Cement
Durability is crucial for reinforced concrete, directly influencing the service life of structures. The presence of aggressive agents, especially chloride ions, significantly impacts durability. This study investigates the differences between ASTM C1202 and IBRACON/NT Build 492 standards in concrete containing various types of cement designed for a characteristic compressive strength of 40 MPa. Forty-eight cylindrical samples were prepared using eight types of Portland cement, including those with blast furnace slag, filler, and pozzolanic materials. Chloride migration tests were performed according to the ASTM C1202/2022 and IBRACON/NT Build 492/1999 methodologies. At a 95% confidence level, the results indicated that concrete made with filler-containing cement (PCII F-SR and PC II F) showed the poorest chloride resistance, with charge passing values exceeding 4000 coulombs (ASTM C1202) and diffusion coefficients above 10 × 10−12 m2/s (IBRACON/NT Build 492). In contrast, concrete containing high slag cement (PC III-SR) and pozzolan cement (PC IV) demonstrated superior resistance to chloride penetration, with charge passing values below 1500 coulombs and diffusion coefficients under 5 × 10−12 m2/s. Notably, discrepancies in classification were observed, as PC II Z (fly-ash based) and PC II E-SR (slag-based) received different ratings under the two methods. ASTM C1202 was found to be more stringent than NT Build 492, highlighting significant variations in the classification criteria between these standards. Based on the findings, new interval values are proposed for classifying concrete regarding the risk of chloride ion penetration, particularly for the ASTM C1202 standard, in order to better align with performance-based durability criteria and improve classification accuracy.