SSSuânia Fabiele Moitinho da Silva

Suânia Fabiele Moitinho da Silva

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Suânia Fabiele Moitinho da Silva has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Impact of Fiber Type on Chloride Ingress in Concrete: A MacroXRF Imaging Analysis

    by Suânia Fabiele Moitinho da Silva, Wanderson Santos de Jesus, Thalles Murilo Santos de Almeida, Renato Quinto de Oliveira Novais, Laio Andrade Sacramento, Joaquim Teixeira de Assis, Marcelino José dos Anjos, José Renato de Castro Pessôa

    Chloride ion penetration is one of the most aggressive threats to reinforced concrete, as it triggers the electrochemical corrosion of steel reinforcement, compromising structural integrity and durability. Chloride ingress occurs through the porous structure of concrete, making permeability control crucial for enhancing structural longevity. Fiber-reinforced concrete (FRC) is widely used to improve durability; however, the effects of different fiber types on chloride resistance remain unclear. This study examines the influence of glass and polypropylene fibers on concrete’s microstructure and chloride penetration resistance. Cylindrical specimens were prepared, including a reference mix without fibers and mixes with 0.25% and 0.50% fiber content by volume. Both fiber types were tested for chloride resistance. The accelerated non-steady-state migration method was employed to determine the resistance coefficients to chloride ion penetration, while X-ray macrofluorescence (MacroXRF) mapped the chlorine infiltration depth in the samples. Compressive strength decreased in all fiber-reinforced samples, with 0.50% glass fiber leading to a 56% reduction in strength. Nevertheless, the XRF results showed that a 0.25% fiber content significantly reduced chloride penetration, with polypropylene fibers outperforming glass fibers. These findings highlight the critical role of fiber type and volume in improving concrete durability, offering insights for designing long-lasting FRC structures in chloride-rich environments.


  • Open Access

    Leveraging Delayed Strength Gains in Supplementary Cementitious Material Concretes: Rethinking Mix Design for Enhanced Cost Efficiency and Sustainability

    by Wanderson Santos de Jesus, Thalles Murilo Santos de Almeida, Suânia Fabiele Moitinho da Silva, Marcelo Tramontin Souza, Eduarda Silva Leal, Ramon Santos Souza, Laio Andrade Sacramento, Ivan Bezerra Allaman, José Renato de Castro Pessôa

    Engineers commonly use the 28-day characteristic strength of concrete for project calculations, but this may not reflect the full-strength potential, especially in concretes with supplementary cementitious materials (SCMs). SCMs, known for their slow reactivity, often delay optimal strength beyond 28 days, requiring higher cement content to speed up early strength development, thus increasing production costs. This study examined the relationship between concrete age and mechanical strength across eight cement types, including tests for axial compression, water absorption, void index, and specific mass. The findings showed that pozzolan and slag cements gained significant long-term strength due to slow pozzolanic reactions. Conversely, limestone filler mixes had lower initial strength and slower progress, likely due to increased porosity from fine fillers. A correlation was found between higher pozzolan content and improved durability, including reduced water absorption and void index. Cost analysis indicated that optimizing cement mix designs for targeted strength levels could reduce production costs, especially for concretes with high SCM content. Using long-term characteristic strength rather than the traditional 28-day strength resulted in approximately 14% savings, particularly for slag- and pozzolan-based cements. The savings were less significant for other cement types, emphasizing the importance of adjusting mix designs based on both performance and financial considerations.


  • Open Access

    Comparative Study of ASTM C1202 and IBRACON/NT Build 492 Testing Methods for Assessing Chloride Ion Penetration in Concretes Using Different Types of Cement

    by Wanderson Santos de Jesus, Suânia Fabiele Moitinho da Silva, Thalles Murilo Santos de Almeida, Marcelo Tramontin Souza, Eduarda Silva Leal, Ramon Santos Souza, Laio Andrade Sacramento, Ivan Bezerra Allaman, José Renato de Castro Pessôa

    Durability is crucial for reinforced concrete, directly influencing the service life of structures. The presence of aggressive agents, especially chloride ions, significantly impacts durability. This study investigates the differences between ASTM C1202 and IBRACON/NT Build 492 standards in concrete containing various types of cement designed for a characteristic compressive strength of 40 MPa. Forty-eight cylindrical samples were prepared using eight types of Portland cement, including those with blast furnace slag, filler, and pozzolanic materials. Chloride migration tests were performed according to the ASTM C1202/2022 and IBRACON/NT Build 492/1999 methodologies. At a 95% confidence level, the results indicated that concrete made with filler-containing cement (PCII F-SR and PC II F) showed the poorest chloride resistance, with charge passing values exceeding 4000 coulombs (ASTM C1202) and diffusion coefficients above 10 × 10−12 m2/s (IBRACON/NT Build 492). In contrast, concrete containing high slag cement (PC III-SR) and pozzolan cement (PC IV) demonstrated superior resistance to chloride penetration, with charge passing values below 1500 coulombs and diffusion coefficients under 5 × 10−12 m2/s. Notably, discrepancies in classification were observed, as PC II Z (fly-ash based) and PC II E-SR (slag-based) received different ratings under the two methods. ASTM C1202 was found to be more stringent than NT Build 492, highlighting significant variations in the classification criteria between these standards. Based on the findings, new interval values are proposed for classifying concrete regarding the risk of chloride ion penetration, particularly for the ASTM C1202 standard, in order to better align with performance-based durability criteria and improve classification accuracy.


  • Open Access

    Assessing the mechanical properties and workability of concretes with stone powder as a sustainable alternative material to natural sand

    by Thalles Murilo Santos de Almeida, Wanderson Santos de Jesus, Marcelo Tramontin Souza, Flávia Araujo Azevedo, Suânia Fabiele Moitinho da Silva, Ramon Santos Souza, José Renato de Castro Pessôa

    The extraction of sand from riverbeds through dredging is a common practice in construction and has given rise to significant environmental repercussions. Sand removal contributes to heightened turbidity and alterations in watercourses, reshaping the original channels due to equipment utilization, and disrupting their flow. In response to these challenges, crushed stone dust emerges as a sustainable alternative material for partially or entirely replacing natural sand in concrete production. This study aimed to evaluate the mechanical properties and workability of concrete with a characteristic compressive strength of 25 MPa, employing total replacement (100% crushed stone dust) and partial replacement (50% crushed stone dust and 50% sand). The materials utilized encompassed crushed stone, natural sand, Portland cement CP II F - 32, crushed stone dust, and a superplasticizer additive. The results indicated no significant difference in compressive strength (P < 0.05), with values of 36.85 MPa and 30.31 MPa for total and partial replacement, respectively, comparable to the reference concrete (33.47 MPa). In terms of tensile strength by split tensile testing, concrete with total and partial replacement achieved 3.09 MPa and 3.23 MPa, respectively, while the reference mix recorded 3.31 MPa. Total replacement posed challenges to the workability of fresh concrete, necessitating a higher dosage of superplasticizer. In conclusion, crushed stone dust demonstrates its capacity to substitute natural sand, either entirely or partially, while upholding mechanical properties comparable to traditional concrete. However, careful consideration of the impact on concrete workability is essential when opting for total replacement of the fine aggregate.

  • Open Access

    Post-Occupancy Evaluation of an educational building: Case study of the ETS-UESC Building

    by Thayse Gama de Carvalho, Suânia Fabiele Moitinho da Silva Reg, Maurício dos Santos Oliveira, Renan Leão Silva, Cleverson Alves de Lima, Vanessa de Freitas Cunha Lins


  • Influência da estrutura dos poros na resistência à compressão de argamassas com incorporação de EPS

    by Suânia Fabiele Moitinho DA Silva, Suian Andrade Meira, José Renato de Castro Pessôa, Joaquim Teixeira Assis

    Encontro nacional de modelagem computacional e encontro de ciência e tecnologia de materiais (978-65-86084-34-4) - Influência Da Estrutura Dos Poros Na Resistência À Compressão De Argamassas Com Incorporação De Eps