Hidetaka Morita
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hidetaka Morita has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Kazunori Uemura
National Cerebral and Cardiovascular Center
4 shared publications - Kei Sato
National Cerebral and Cardiovascular Center
4 shared publications - Keita Saku
National Cerebral and Cardiovascular Center
4 shared publications Masafumi Fukumitsu
National Cerebral and Cardiovascular Center
4 shared publications- Masahiro Otake
National Cerebral and Cardiovascular Center
4 shared publications - Takuya Nishikawa
National Cerebral and Cardiovascular Center
4 shared publications
Latest Publications
- 1 April 2026
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 330 (4) , H1241-H1256
Understanding the hemodynamic effects of milrinone in normal and failing hearts: an experimental study using the circulatory equilibrium framework in canines
Analysis using a generalized circulatory equilibrium framework demonstrates that milrinone reduces stressed blood volume, shifting the venous return curve downward in both normal and heart failure (HF) models. In contrast, milrinone shifts the cardiac output (CO) curve upward only in the HF model. Left atrial pressure is reduced without CO reduction in the HF model, whereas CO decreases in the normal model. These findings indicate that circulatory equilibrium responses to milrinone depend on cardiac function.
- 1 April 2026
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 330 (4) , H1241-H1256
Understanding the hemodynamic effects of milrinone in normal and failing hearts: an experimental study using the circulatory equilibrium framework in canines
Analysis using a generalized circulatory equilibrium framework demonstrates that milrinone reduces stressed blood volume, shifting the venous return curve downward in both normal and heart failure (HF) models. In contrast, milrinone shifts the cardiac output (CO) curve upward only in the HF model. Left atrial pressure is reduced without CO reduction in the HF model, whereas CO decreases in the normal model. These findings indicate that circulatory equilibrium responses to milrinone depend on cardiac function.
- 20 August 2025
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
One Surface Fits All: Validating the Venous Return Model Across Species and Scales in Circulatory Equilibrium
In the generalized framework of circulatory equilibrium, the cardiac output (CO), right (RAP) and left (LAP) atrial pressures at equilibrium are predicted from the intersection between the CO curve and venous return (VR) surface. The VR surface is represented by the following equation: VR=V/W-GS∙RAP-GP∙LAP, where V is stressed blood volume, and W, GS, and GP are parameters. For future clinical application of this framework, we examined whether the VR surface is valid, whether the parameters are allometrically scalable based on Kleiber’s law, and whether the VR surface with allometrically scaled parameters accurately predicts hemodynamic variables across different animal species and a diverse range of body weights (BW). Anesthetized dogs (n=18) and pigs (n=8) with BW ranging from 9 to 50 kg were used. In 20 animals, we characterized the VR surface under total heart bypass and examined allometric scalability of the parameters. In 19 animals, we assessed whether the allometrically scaled VR surface allows accurate predictions of CO, LAP, and RAP. VR correlated significantly with RAP and LAP as per the equation, with a median coefficient of determination (r2) of 0.95. GS and GP were allometrically scalable with BW0.75, but W was not. However, if population-representative W was combined with allometrically scaled GS and GP, predicted CO, RAP, and LAP correlated strongly with those measured (r2=0.99, 0.98, and 0.94, respectively). In conclusion, the VR surface is valid across species and body sizes, and the allometrically scaled VR surface allows accurate hemodynamic prediction, supporting the clinical application potential of this framework.
- 20 August 2025
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
One Surface Fits All: Validating the Venous Return Model Across Species and Scales in Circulatory Equilibrium
In the generalized framework of circulatory equilibrium, the cardiac output (CO), right (RAP) and left (LAP) atrial pressures at equilibrium are predicted from the intersection between the CO curve and venous return (VR) surface. The VR surface is represented by the following equation: VR=V/W-GS∙RAP-GP∙LAP, where V is stressed blood volume, and W, GS, and GP are parameters. For future clinical application of this framework, we examined whether the VR surface is valid, whether the parameters are allometrically scalable based on Kleiber’s law, and whether the VR surface with allometrically scaled parameters accurately predicts hemodynamic variables across different animal species and a diverse range of body weights (BW). Anesthetized dogs (n=18) and pigs (n=8) with BW ranging from 9 to 50 kg were used. In 20 animals, we characterized the VR surface under total heart bypass and examined allometric scalability of the parameters. In 19 animals, we assessed whether the allometrically scaled VR surface allows accurate predictions of CO, LAP, and RAP. VR correlated significantly with RAP and LAP as per the equation, with a median coefficient of determination (r2) of 0.95. GS and GP were allometrically scalable with BW0.75, but W was not. However, if population-representative W was combined with allometrically scaled GS and GP, predicted CO, RAP, and LAP correlated strongly with those measured (r2=0.99, 0.98, and 0.94, respectively). In conclusion, the VR surface is valid across species and body sizes, and the allometrically scaled VR surface allows accurate hemodynamic prediction, supporting the clinical application potential of this framework.
- 10 July 2025
- Published by American Physiological Society in American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
Impact of dopamine on baroreflex-mediated sympathetic arterial pressure regulation in rats: An open-loop analysis
Dopamine is commonly used to treat hemodynamic collapse, but its effect on baroreflex-mediated sympathetic arterial pressure (AP) regulation remains to be elucidated. We quantified the effects of dopamine on AP regulation using a baroreflex open-loop analysis by measuring sympathetic nerve activity (SNA) and AP in response to stepwise changes in carotid sinus pressure (CSP) before and during intravenous infusion of dopamine at 2, 10, and 20 μg·kg−1·min−1 in anesthetized rats (n = 8). We analyzed the CSP–SNA relationship (neural arc) and the SNA–AP relationship (peripheral arc), and constructed a baroreflex equilibrium diagram. The gain at the operating point was calculated from the product of the tangential slope of the neural arc and the slope of the peripheral arc. Compared to baseline, dopamine at 20 μg·kg⁻¹·min⁻¹ significantly reduced the maximum gain of the neural arc [from 1.898 ± 0.150 to 1.277 ± 0.205 %/mmHg ( P = 0.014)]. Compared to baseline, dopamine at 10 and 20 μg·kg⁻¹·min⁻¹ significantly reduced the slope of the peripheral arc [from 0.806 ± 0.079 to 0.645 ± 0.091 mmHg/% ( P = 0.031) and 0.633 ± 0.100 mmHg/% ( P = 0.020), respectively] and the operating point gain [from 0.800 ± 0.187 to 0.462 ± 0.153 mmHg/mmHg ( P = 0.008) and 0.345 ± 0.122 mmHg/mmHg ( P < 0.001)], while maintaining the operating point AP. In conclusion, dopamine at 10 and 20 μg·kg⁻¹·min⁻¹ maintained the operating point AP but significantly reduced the operating point gain for AP regulation, potentially increasing AP variability and instability.
- 10 July 2025
- Published by American Physiological Society in American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
Impact of dopamine on baroreflex-mediated sympathetic arterial pressure regulation in rats: An open-loop analysis
Dopamine is commonly used to treat hemodynamic collapse, but its effect on baroreflex-mediated sympathetic arterial pressure (AP) regulation remains to be elucidated. We quantified the effects of dopamine on AP regulation using a baroreflex open-loop analysis by measuring sympathetic nerve activity (SNA) and AP in response to stepwise changes in carotid sinus pressure (CSP) before and during intravenous infusion of dopamine at 2, 10, and 20 μg·kg−1·min−1 in anesthetized rats (n = 8). We analyzed the CSP–SNA relationship (neural arc) and the SNA–AP relationship (peripheral arc), and constructed a baroreflex equilibrium diagram. The gain at the operating point was calculated from the product of the tangential slope of the neural arc and the slope of the peripheral arc. Compared to baseline, dopamine at 20 μg·kg⁻¹·min⁻¹ significantly reduced the maximum gain of the neural arc [from 1.898 ± 0.150 to 1.277 ± 0.205 %/mmHg ( P = 0.014)]. Compared to baseline, dopamine at 10 and 20 μg·kg⁻¹·min⁻¹ significantly reduced the slope of the peripheral arc [from 0.806 ± 0.079 to 0.645 ± 0.091 mmHg/% ( P = 0.031) and 0.633 ± 0.100 mmHg/% ( P = 0.020), respectively] and the operating point gain [from 0.800 ± 0.187 to 0.462 ± 0.153 mmHg/mmHg ( P = 0.008) and 0.345 ± 0.122 mmHg/mmHg ( P < 0.001)], while maintaining the operating point AP. In conclusion, dopamine at 10 and 20 μg·kg⁻¹·min⁻¹ maintained the operating point AP but significantly reduced the operating point gain for AP regulation, potentially increasing AP variability and instability.
- Open Access
- 1 February 2025
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 328 (2) , H361-H376
Development of a framework for the hemodynamic impact of positive end-expiratory pressure in normal and heart failure conditions
Positive end-expiratory pressure (PEEP) has both the benefit of improving respiratory status and the disadvantage of deteriorating hemodynamics. As the effects of PEEP vary depending on cardiac function, optimizing PEEP setting remains challenging. This study is the first to systematically elucidate the impact of PEEP on hemodynamics with consideration of cardiac function and establish a validated framework. This novel framework provides a comprehensive understanding of the hemodynamic effects of PEEP.
- 1 February 2025
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 328 (2) , H361-H376
Open AccessDevelopment of a framework for the hemodynamic impact of positive end-expiratory pressure in normal and heart failure conditions
Positive end-expiratory pressure (PEEP) has both the benefit of improving respiratory status and the disadvantage of deteriorating hemodynamics. As the effects of PEEP vary depending on cardiac function, optimizing PEEP setting remains challenging. This study is the first to systematically elucidate the impact of PEEP on hemodynamics with consideration of cardiac function and establish a validated framework. This novel framework provides a comprehensive understanding of the hemodynamic effects of PEEP.
- Open Access
- 1 January 2025
- Published by XMLink in International Journal of Heart Failure
- Vol. 7 (3) , 125-138
Impact of Venoarterial Extracorporeal Membrane Oxygenation on Hemodynamics and Cardiac Mechanics: Insights From Pressure-Volume Loop Analysis
Otake M, et al. Int J Heart Fail. 2025 Jul;7(3):125-138. https://doi.org/10.36628/ijhf.2025.0005
- 1 January 2025
- Published by XMLink in International Journal of Heart Failure
- Vol. 7 (3) , 125-138
Open AccessImpact of Venoarterial Extracorporeal Membrane Oxygenation on Hemodynamics and Cardiac Mechanics: Insights From Pressure-Volume Loop Analysis
Otake M, et al. Int J Heart Fail. 2025 Jul;7(3):125-138. https://doi.org/10.36628/ijhf.2025.0005