Meng Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Meng Wang has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Yuce Liu
China Three Gorges Corporation, Wuhan 430010, China
3 shared publications - Yue Hu
CTG Wuhan Science and Technology Innovation Park, China Three Gorges Corporation, Wuhan 430010, China
3 shared publications - Rujie Liu
China Yangtze Power Co., Ltd., Wuhan 430010, China
2 shared publications - Chaohui Zhou
CTG Wuhan Science and Technology Innovation Park, China Three Gorges Corporation, Wuhan 430010, China
1 shared publication - Chaohui Zhou
China Three Gorges Corporation, Wuhan 430010, China
1 shared publication - Chongzheng Li
School of Environmental Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
1 shared publication
Latest Publications
- Open Access
A Precision Measurement Method for Rooftop Photovoltaic Capacity Using Drone and Publicly Available Imagery
Against the global backdrop of energy transition, the precise assessment of urban rooftop photovoltaic (PV) system capacity is recognized as crucial for optimizing the energy structure and enhancing the sustainable utilization efficiency of spatial resources. Publicly available aerial imagery is characterized by non-orthorectified issues; direct utilization is known to lead to geometric distortions in rooftop PV and errors in capacity prediction. To address this, a dual-optimization framework is proposed in this study, integrating monocular vision-based 3D reconstruction with a lightweight linear model. Leveraging the orthogonal characteristics of building structures, camera self-calibration and 3D reconstruction are achieved through geometric constraints imposed by vanishing points. Scale distortion is suppressed via the incorporation of a multi-dimensional geometric constraint error control strategy. Concurrently, a linear capacity-area model is constructed, thereby simplifying the complexity inherent in traditional multi-parameter fitting. Utilizing drone oblique photography and Google Earth public imagery, 3D reconstruction was performed for 20 PV-equipped buildings in Wuhan City. Two buildings possessing high-precision field survey data were selected as typical experimental subjects for validation. The results demonstrate that the 3D reconstruction method reduced the mean absolute percentage error (MAPE)—used here as an estimator of measurement uncertainty—of PV area identification from 10.58% (achieved by the 2D method) to 3.47%, while the coefficient of determination (R2) for the capacity model reached 0.9548. These results suggest that this methodology can provide effective technical support for low-cost, high-precision urban rooftop PV resource surveys. It has the potential to significantly enhance the reliability of energy planning data, thereby contributing to the efficient development of urban spatial resources and the achievement of sustainable energy transition goals.
Open AccessA Precision Measurement Method for Rooftop Photovoltaic Capacity Using Drone and Publicly Available Imagery
Against the global backdrop of energy transition, the precise assessment of urban rooftop photovoltaic (PV) system capacity is recognized as crucial for optimizing the energy structure and enhancing the sustainable utilization efficiency of spatial resources. Publicly available aerial imagery is characterized by non-orthorectified issues; direct utilization is known to lead to geometric distortions in rooftop PV and errors in capacity prediction. To address this, a dual-optimization framework is proposed in this study, integrating monocular vision-based 3D reconstruction with a lightweight linear model. Leveraging the orthogonal characteristics of building structures, camera self-calibration and 3D reconstruction are achieved through geometric constraints imposed by vanishing points. Scale distortion is suppressed via the incorporation of a multi-dimensional geometric constraint error control strategy. Concurrently, a linear capacity-area model is constructed, thereby simplifying the complexity inherent in traditional multi-parameter fitting. Utilizing drone oblique photography and Google Earth public imagery, 3D reconstruction was performed for 20 PV-equipped buildings in Wuhan City. Two buildings possessing high-precision field survey data were selected as typical experimental subjects for validation. The results demonstrate that the 3D reconstruction method reduced the mean absolute percentage error (MAPE)—used here as an estimator of measurement uncertainty—of PV area identification from 10.58% (achieved by the 2D method) to 3.47%, while the coefficient of determination (R2) for the capacity model reached 0.9548. These results suggest that this methodology can provide effective technical support for low-cost, high-precision urban rooftop PV resource surveys. It has the potential to significantly enhance the reliability of energy planning data, thereby contributing to the efficient development of urban spatial resources and the achievement of sustainable energy transition goals.
- Open Access
Study on Quantifying Soil Thermal Imbalance in Shallow Coaxial Borehole Heat Exchangers
The bore field in ground source heat pump (GSHP) systems usually encounters thermal accumulation in long-term operation, but there is no quantitative index evaluating this process and its magnitude. A heat accumulation evaluation metric has been proposed, based on the linear trend Slope (°C/a) of the curve of soil temperature variation. Using this metric, the influence of various factors on soil temperature has been quantitatively analyzed. The results indicate that, under constant heating durations, each 10-day extension of cooling periods leads to an increase of 0.038 °C/a in soil temperature. Extending the recovery period within an annual cycle facilitates soil self-recovery and mitigates subsurface thermal accumulation. Increasing the spacing between boreholes effectively reduces thermal interference, whereas a greater number of boreholes exacerbates thermal accumulation. Deepening vertical boreholes from 100 m to 200 m reduces the average annual soil temperature increase by 0.1076 °C. Appropriately increasing backfill thermal conductivity enhances heat exchange efficiency and suppresses thermal accumulation. Higher water flow rates result in logarithmic increases in the evaluation metric, thereby intensifying soil thermal accumulation. Intermittent operation extends recovery periods, thereby alleviating soil thermal imbalance. Under balanced cooling and heating loads, increasing the system lifespan from 10 a to 30 a reduces the evaluation metric by 47.2%.
Open AccessStudy on Quantifying Soil Thermal Imbalance in Shallow Coaxial Borehole Heat Exchangers
The bore field in ground source heat pump (GSHP) systems usually encounters thermal accumulation in long-term operation, but there is no quantitative index evaluating this process and its magnitude. A heat accumulation evaluation metric has been proposed, based on the linear trend Slope (°C/a) of the curve of soil temperature variation. Using this metric, the influence of various factors on soil temperature has been quantitatively analyzed. The results indicate that, under constant heating durations, each 10-day extension of cooling periods leads to an increase of 0.038 °C/a in soil temperature. Extending the recovery period within an annual cycle facilitates soil self-recovery and mitigates subsurface thermal accumulation. Increasing the spacing between boreholes effectively reduces thermal interference, whereas a greater number of boreholes exacerbates thermal accumulation. Deepening vertical boreholes from 100 m to 200 m reduces the average annual soil temperature increase by 0.1076 °C. Appropriately increasing backfill thermal conductivity enhances heat exchange efficiency and suppresses thermal accumulation. Higher water flow rates result in logarithmic increases in the evaluation metric, thereby intensifying soil thermal accumulation. Intermittent operation extends recovery periods, thereby alleviating soil thermal imbalance. Under balanced cooling and heating loads, increasing the system lifespan from 10 a to 30 a reduces the evaluation metric by 47.2%.
- Open Access
Energy Performance Study of a Data Center Combined Cooling System Integrated with Heat Storage and Waste Heat Recovery System
The energy efficiency of data centers has become an urgent problem as it is enjoying rapid development. This study proposes an integrated energy system involving a data center with different renewable energy sources and waste heat recovery, which can consider the partial and unsteady working load of data center. A dynamic and sophisticated system simulation model is established, which can provide both reliable and fast evaluations but also allow flexible extension of additional components. It is found that the free natural resource cooling system can cover about 28% of cooling demand. Compared to the reference condition, the proposed energy system achieves significant energy-saving benefits, with an energy-saving rate of 16.4%. The system COP increases from 3.88 to 4.64, and the PUE decreases from 1.36 to 1.30, resulting in a 23.45% reduction in electricity expenses. By integrating a waste heat recovery system, the heat pump can absorb approximately 3.57 million kWh of heat from the data center, providing approximately 4.587 million kWh of heating energy for users. The rooftop PV system generates approximately 370,000 kWh of electricity annually, covering approximately 8% of the total electricity consumption of the data center. This study can offer a new channel for the energy efficiency enhancement of data centers.
Open AccessEnergy Performance Study of a Data Center Combined Cooling System Integrated with Heat Storage and Waste Heat Recovery System
The energy efficiency of data centers has become an urgent problem as it is enjoying rapid development. This study proposes an integrated energy system involving a data center with different renewable energy sources and waste heat recovery, which can consider the partial and unsteady working load of data center. A dynamic and sophisticated system simulation model is established, which can provide both reliable and fast evaluations but also allow flexible extension of additional components. It is found that the free natural resource cooling system can cover about 28% of cooling demand. Compared to the reference condition, the proposed energy system achieves significant energy-saving benefits, with an energy-saving rate of 16.4%. The system COP increases from 3.88 to 4.64, and the PUE decreases from 1.36 to 1.30, resulting in a 23.45% reduction in electricity expenses. By integrating a waste heat recovery system, the heat pump can absorb approximately 3.57 million kWh of heat from the data center, providing approximately 4.587 million kWh of heating energy for users. The rooftop PV system generates approximately 370,000 kWh of electricity annually, covering approximately 8% of the total electricity consumption of the data center. This study can offer a new channel for the energy efficiency enhancement of data centers.