Jinhao Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jinhao Wang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- William R. Taylor
ETH Zurich
3 shared publications Florian Vogl
ETH Zurich
2 shared publicationsPascal Schütz
ETH Zurich
2 shared publicationsSaša Ćuković
ETH Zurich
2 shared publications- Edmond Lou
University of Alberta
1 shared publication - Lejun Zhou
Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong, China
1 shared publication
Latest Publications
- Open Access
- 19 June 2026
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 21 (11) , 2375-2387
Pose-aware deep perceptual similarity for iterative 2D/3D registration of knee joints using contrastive learning
Purpose: Accurate 2D/3D registration between fluoroscopic X-ray images and preoperative CT models is essential to get dynamic joint kinematics in computer-assisted orthopedic analysis. Traditional correlation-based similarity metrics in model–image optimization often suffer from limited capture range and sensitivity to noise and occlusion. Methods: We propose a pose-aware deep perceptual metric using contrastive learning for enlarged capture range and improved robustness. Inspired by LPIPS, our network was specialized and designed for 2D/3D fluoroscopic image registration, where the supervision reflects true 3D transformation discrepancies. The learned metric is integrated into a differentiable 2D/3D registration framework, enabling gradient-based optimization. Results: The proposed metric enlarges the capture range of 2D/3D registration and smooths the loss landscape, while ensuring the required accuracy for automated registration. Our metric outperforms conventional similarity measures and standard LPIPS, presenting zero-shot ability for unseen low-contrast fluoroscopic conditions. Conclusion: The proposed metric provides a robust and differentiable metric for fluoroscopic 2D/3D registration, improving accuracy in joint kinematics analysis for both single- and dual-plane fluoroscopy.
- 19 June 2026
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 21 (11) , 2375-2387
Open AccessPose-aware deep perceptual similarity for iterative 2D/3D registration of knee joints using contrastive learning
Purpose: Accurate 2D/3D registration between fluoroscopic X-ray images and preoperative CT models is essential to get dynamic joint kinematics in computer-assisted orthopedic analysis. Traditional correlation-based similarity metrics in model–image optimization often suffer from limited capture range and sensitivity to noise and occlusion. Methods: We propose a pose-aware deep perceptual metric using contrastive learning for enlarged capture range and improved robustness. Inspired by LPIPS, our network was specialized and designed for 2D/3D fluoroscopic image registration, where the supervision reflects true 3D transformation discrepancies. The learned metric is integrated into a differentiable 2D/3D registration framework, enabling gradient-based optimization. Results: The proposed metric enlarges the capture range of 2D/3D registration and smooths the loss landscape, while ensuring the required accuracy for automated registration. Our metric outperforms conventional similarity measures and standard LPIPS, presenting zero-shot ability for unseen low-contrast fluoroscopic conditions. Conclusion: The proposed metric provides a robust and differentiable metric for fluoroscopic 2D/3D registration, improving accuracy in joint kinematics analysis for both single- and dual-plane fluoroscopy.
- 20 September 2025
- Published by Springer Nature
- p. 645-654
Veriserum: A Dual-Plane Fluoroscopic Dataset with Knee Implant Phantoms for Deep Learning in Medical Imaging
- 20 September 2025
- Published by Springer Nature
- p. 645-654
Veriserum: A Dual-Plane Fluoroscopic Dataset with Knee Implant Phantoms for Deep Learning in Medical Imaging
- Open Access
Veriserum: A dual-plane fluoroscopic dataset with knee implant phantoms for deep learning in medical imaging
Veriserum is an open-source dataset designed to support the training of deep learning registration for dual-plane fluoroscopic analysis. It comprises approximately 110,000 X-ray images of 10 knee implant pair combinations (2 femur and 5 tibia implants) captured during 1,600 trials, incorporating poses associated with daily activities such as level gait and ramp descent. Each image is annotated with an automatically registered ground-truth pose, while 200 images include manually registered poses for benchmarking. Key features of Veriserum include dual-plane images and calibration tools. The dataset aims to support the development of applications such as 2D/3D image registration, image segmentation, X-ray distortion correction, and 3D reconstruction. Freely accessible, Veriserum aims to advance computer vision and medical imaging research by providing a reproducible benchmark for algorithm development and evaluation. The Veriserum dataset used in this study is publicly available via https://movement.ethz.ch/data-repository/veriserum.html, with the data stored at ETH Zürich Research Collections: https://doi.org/10.3929/ethz-b-000701146.
Open AccessVeriserum: A dual-plane fluoroscopic dataset with knee implant phantoms for deep learning in medical imaging
Veriserum is an open-source dataset designed to support the training of deep learning registration for dual-plane fluoroscopic analysis. It comprises approximately 110,000 X-ray images of 10 knee implant pair combinations (2 femur and 5 tibia implants) captured during 1,600 trials, incorporating poses associated with daily activities such as level gait and ramp descent. Each image is annotated with an automatically registered ground-truth pose, while 200 images include manually registered poses for benchmarking. Key features of Veriserum include dual-plane images and calibration tools. The dataset aims to support the development of applications such as 2D/3D image registration, image segmentation, X-ray distortion correction, and 3D reconstruction. Freely accessible, Veriserum aims to advance computer vision and medical imaging research by providing a reproducible benchmark for algorithm development and evaluation. The Veriserum dataset used in this study is publicly available via https://movement.ethz.ch/data-repository/veriserum.html, with the data stored at ETH Zürich Research Collections: https://doi.org/10.3929/ethz-b-000701146.
- Open Access
The Application of Integrated Force and Temperature Sensors to Enhance Orthotic Treatment Monitoring in Adolescent Idiopathic Scoliosis: A Pilot Study
Orthosis-wearing compliance is crucial for achieving positive treatment outcomes in patients with adolescent idiopathic scoliosis (AIS), for whom 23 h of daily wear is typically prescribed. However, self-reported compliance is subjective and often based on patients’ memory, leading to inaccuracies. While portable electronic devices have been developed to objectively monitor compliance, relying solely on temperature or force data can be insufficient. This study introduced a novel method that integrated both force and temperature data to estimate orthosis-wearing compliance. Twelve patients (eight females and four males) diagnosed with moderate AIS were included. Each patient was prescribed a thoracic-lumbar-sacral orthosis equipped with an integrated force and temperature sensor system. After one month of orthotic treatment, self-reported wear time averaged 17.8 ± 6.2 h/day, while the sensor indicated an average wear time of 13.3 ± 5.0 h/day. Most patients overestimated their compliance. Nighttime was the most common period for orthosis wear (6.1 h/day), whereas compliance during school hours (2.8 h/day) and after-school hours (3.7 h/day) was lower. The integration of force and temperature sensors provides a more comprehensive understanding of orthosis compliance. Future studies with larger samples and longer monitoring periods are needed to investigate the correlation between compliance and treatment outcomes.
Open AccessThe Application of Integrated Force and Temperature Sensors to Enhance Orthotic Treatment Monitoring in Adolescent Idiopathic Scoliosis: A Pilot Study
Orthosis-wearing compliance is crucial for achieving positive treatment outcomes in patients with adolescent idiopathic scoliosis (AIS), for whom 23 h of daily wear is typically prescribed. However, self-reported compliance is subjective and often based on patients’ memory, leading to inaccuracies. While portable electronic devices have been developed to objectively monitor compliance, relying solely on temperature or force data can be insufficient. This study introduced a novel method that integrated both force and temperature data to estimate orthosis-wearing compliance. Twelve patients (eight females and four males) diagnosed with moderate AIS were included. Each patient was prescribed a thoracic-lumbar-sacral orthosis equipped with an integrated force and temperature sensor system. After one month of orthotic treatment, self-reported wear time averaged 17.8 ± 6.2 h/day, while the sensor indicated an average wear time of 13.3 ± 5.0 h/day. Most patients overestimated their compliance. Nighttime was the most common period for orthosis wear (6.1 h/day), whereas compliance during school hours (2.8 h/day) and after-school hours (3.7 h/day) was lower. The integration of force and temperature sensors provides a more comprehensive understanding of orthosis compliance. Future studies with larger samples and longer monitoring periods are needed to investigate the correlation between compliance and treatment outcomes.