Jinghan Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jinghan Zhang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Dongqing Li
College of Physics and Optoelectronic Engineering, Shenzhen Key Laboratory of Sensor Technology, Shenzhen University, Shenzhen, China
1 shared publication - Lei Xiao
College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China
1 shared publication - Xinghong Chen
College of Physics and Optoelectronic Engineering, Shenzhen University 1 , Shenzhen 518060
1 shared publication - Xuejin Li
Shenzhen Key Laboratory of Sensor Technology, Shenzhen University, Shenzhen, China
1 shared publication - Xueming Hong
College of Physics and Optoelectronic Engineering, Shenzhen Key Laboratory of Sensor Technology, Shenzhen University, Shenzhen, China
1 shared publication - Yan Wang
College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China
1 shared publication
Latest Publications
- Open Access
- 6 February 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (2) , 90
Enhanced Sensitivity Mach–Zehnder Interferometer-Based Tapered-in-Tapered Fiber-Optic Biosensor for the Immunoassay of C-Reactive Protein
A Mach–Zehnder interferometer-based tapered-in-tapered fiber-optic biosensor was introduced in this paper. By integrating a micro-tapered fiber into a single tapered fiber structure, the design enhances sensitivity, signal-to-noise ratio, and resolution capability, while reducing the length of the sensing fiber. Through simulation analysis, it was found that the tapered-in-tapered fiber significantly improved the refractive index detection sensitivity by exciting a stronger evanescent field effect. The experimental comparison between the tapered-in-tapered fiber and traditional tapered fiber showed a 1.7-fold increase in sensitivity, reaching 3266.78 nm/RIU within the refractive index range of 1.3326 to 1.3414. Furthermore, to expand its application prospects in the biomedical field, glutaraldehyde cross-linking technology was used to immobilize C-reactive protein (CRP) antibodies on the surface of the tapered-in-tapered fiber, successfully creating a biosensing platform for the specific recognition of CRP. The experimental results demonstrate that this novel biosensor can rapidly and accurately detect CRP molecules at different concentrations with a detection limit of 0.278 μg/mL, and that it exhibits good selectivity and repeatability. This tapered-in-tapered fiber-optic biosensor provides new insights into the development of high-performance fiber-optic immunosensors and shows broad application potential in immunology research and early disease diagnosis.
- 6 February 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (2) , 90
Open AccessEnhanced Sensitivity Mach–Zehnder Interferometer-Based Tapered-in-Tapered Fiber-Optic Biosensor for the Immunoassay of C-Reactive Protein
A Mach–Zehnder interferometer-based tapered-in-tapered fiber-optic biosensor was introduced in this paper. By integrating a micro-tapered fiber into a single tapered fiber structure, the design enhances sensitivity, signal-to-noise ratio, and resolution capability, while reducing the length of the sensing fiber. Through simulation analysis, it was found that the tapered-in-tapered fiber significantly improved the refractive index detection sensitivity by exciting a stronger evanescent field effect. The experimental comparison between the tapered-in-tapered fiber and traditional tapered fiber showed a 1.7-fold increase in sensitivity, reaching 3266.78 nm/RIU within the refractive index range of 1.3326 to 1.3414. Furthermore, to expand its application prospects in the biomedical field, glutaraldehyde cross-linking technology was used to immobilize C-reactive protein (CRP) antibodies on the surface of the tapered-in-tapered fiber, successfully creating a biosensing platform for the specific recognition of CRP. The experimental results demonstrate that this novel biosensor can rapidly and accurately detect CRP molecules at different concentrations with a detection limit of 0.278 μg/mL, and that it exhibits good selectivity and repeatability. This tapered-in-tapered fiber-optic biosensor provides new insights into the development of high-performance fiber-optic immunosensors and shows broad application potential in immunology research and early disease diagnosis.