Naoki Oneda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Naoki Oneda has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Adrian Radomski
SDU Health Informatics and Technology, The Maersk Mc-Kinney Moller Institute, University of Southern Denmark, Odense, Denmark
1 shared publication - Akinori Ueno
Department of Electrical and Electronic Engineering, Tokyo Denki University, Tokyo, Japan
1 shared publication - Daniel Teichmann
SDU Health Informatics and Technology, The Maersk Mc-Kinney Moller Institute, University of Southern Denmark, Odense, Denmark
1 shared publication - Koki Oshima
Department of Electrical and Electronic Engineering, Tokyo Denki University, Tokyo, Japan
1 shared publication - Masaki Arai
Department of Electrical and Electronic Engineering, Tokyo Denki University, Tokyo, Japan
1 shared publication
Latest Publications
- Open Access
- 16 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (3) , 4157-4166
Reflective PPG Sensor Measures Heart Rate Through Clothing During Driving
This paper presents the development and validation of a reflective photoplethysmography (PPG) sensor designed for unobtrusive heart rate monitoring through clothing in automotive environments. The sensor is integrated into the backrest of a car seat and employs an optimized hardware configuration to enhance signal acquisition and mitigate motion artifacts during driving. Its performance was evaluated in two scenarios: a validation study with 12 participants driving for a total of 316 minutes and a longitudinal field study encompassing 1080 minutes of driving across three European countries. The validation study demonstrated a concordance correlation coefficient (CCC) of 0.89, a mean absolute error (MAE) of 2.51 bpm, and a mean absolute percentage error (MAPE) of 3.07%. Gender-specific analysis revealed minimal differences in performance, with an overall coverage rate of 77.60%. The longitudinal study confirmed the sensor’s reliability over prolonged periods, achieving a CCC of 0.976, MAE of 0.844 bpm, and MAPE of 1.04%, with a 95.92% coverage rate across diverse driving conditions.
- 16 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (3) , 4157-4166
Open AccessReflective PPG Sensor Measures Heart Rate Through Clothing During Driving
This paper presents the development and validation of a reflective photoplethysmography (PPG) sensor designed for unobtrusive heart rate monitoring through clothing in automotive environments. The sensor is integrated into the backrest of a car seat and employs an optimized hardware configuration to enhance signal acquisition and mitigate motion artifacts during driving. Its performance was evaluated in two scenarios: a validation study with 12 participants driving for a total of 316 minutes and a longitudinal field study encompassing 1080 minutes of driving across three European countries. The validation study demonstrated a concordance correlation coefficient (CCC) of 0.89, a mean absolute error (MAE) of 2.51 bpm, and a mean absolute percentage error (MAPE) of 3.07%. Gender-specific analysis revealed minimal differences in performance, with an overall coverage rate of 77.60%. The longitudinal study confirmed the sensor’s reliability over prolonged periods, achieving a CCC of 0.976, MAE of 0.844 bpm, and MAPE of 1.04%, with a 95.92% coverage rate across diverse driving conditions.