Qingyin Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Qingyin Sun has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Min Wang
School of Microelectronics, Southern University of Science and Technology, Shenzhen, CHINA
2 shared publications - Chu Qin
School of Microelectronics, Southern University of Science and Technology, Shenzhen, CHINA
1 shared publication - Chuheng Fu
Southern University of Science and Technology
1 shared publication - Jiaxin Wu
School of Microelectronics, Southern University of Science and Technology, Shenzhen, CHINA
1 shared publication Jinghui Chao
School of Microelectronics, Southern University of Science and Technology, Shenzhen, CHINA
1 shared publicationYing Jin
School of Microelectronics, Southern University of Science and Technology, Shenzhen, CHINA
1 shared publication
Latest Publications
- 6 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 72 (11) , 6109-6113
Infrared Thermal Detector With Ag–Graphene Composite Absorber
Infrared (IR) thermal detectors depend on the measurable property variations of the thermosensitive materials due to the temperature rise caused by the absorption of IR radiation. Due to the unique wavelength conversion feature, the fluorescent thermal detector has become a promising candidate in optical readout IR detectors. However, the IR absorption and utilization still restrict its wide application. Here, we report the Ag–graphene composite, which is utilized to enhance the absorption in the mid-infrared (MIR) band for a fluorescent thermal detector. The plasmonic resonance of the Ag NPs creates an enhanced localized electric field that allows graphene to absorb more IR radiation and convert it into thermal to heat the phosphor, resulting in a higher temperature rise. The detector utilizing the Ag–graphene composite demonstrates a high mid-IR absorption of up to 65.57% at 9μm, and the thermal responsivity (relative variation in gray value of luminous output) is enhanced by a factor of 2.2 at a 313-K target. Our work expands the use of graphene for IR absorption and detection beyond the ultralong wavelength limit and suggests that even shorter wavelength may be reached using other plasmonic structures.
- 6 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 72 (11) , 6109-6113
Infrared Thermal Detector With Ag–Graphene Composite Absorber
Infrared (IR) thermal detectors depend on the measurable property variations of the thermosensitive materials due to the temperature rise caused by the absorption of IR radiation. Due to the unique wavelength conversion feature, the fluorescent thermal detector has become a promising candidate in optical readout IR detectors. However, the IR absorption and utilization still restrict its wide application. Here, we report the Ag–graphene composite, which is utilized to enhance the absorption in the mid-infrared (MIR) band for a fluorescent thermal detector. The plasmonic resonance of the Ag NPs creates an enhanced localized electric field that allows graphene to absorb more IR radiation and convert it into thermal to heat the phosphor, resulting in a higher temperature rise. The detector utilizing the Ag–graphene composite demonstrates a high mid-IR absorption of up to 65.57% at 9μm, and the thermal responsivity (relative variation in gray value of luminous output) is enhanced by a factor of 2.2 at a 313-K target. Our work expands the use of graphene for IR absorption and detection beyond the ultralong wavelength limit and suggests that even shorter wavelength may be reached using other plasmonic structures.
- 16 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (3) , 4290-4297
Accordion-Inspired Flexible Pressure Sensor Based on Folded Interdigital Electrode
Flexible piezoresistive pressure sensors have attracted great attention for its wide application in human-machine interface, wearable electronics and so on. However, it is often difficult to obtain sensors with both high sensitivity and wide sensing range. Here, we propose an accordion-inspired piezoresistive pressure sensor as a new solution. The flexible interdigital electrode is bent by mold pressing, and then stacked along the compression direction with paper-based conductive sensing layers by appropriate assembly and encapsulation. The stacked structure obviously increases the change and upper limit of contact area between sensing layers and electrodes, which effectively improves the sensitivity of the pressure sensor over the whole sensing range compared to single-layered structure. Thus, the sensor in this work shows high sensitivities (more than 300 kPa−1) in a wide sensing range (3.6-714.3 kPa), with a maximum value of 1431.7 kPa−1. This work provides a new strategy to design and fabricate piezoresistive pressure sensors with high sensitivity and wide sensing range.
- 16 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (3) , 4290-4297
Accordion-Inspired Flexible Pressure Sensor Based on Folded Interdigital Electrode
Flexible piezoresistive pressure sensors have attracted great attention for its wide application in human-machine interface, wearable electronics and so on. However, it is often difficult to obtain sensors with both high sensitivity and wide sensing range. Here, we propose an accordion-inspired piezoresistive pressure sensor as a new solution. The flexible interdigital electrode is bent by mold pressing, and then stacked along the compression direction with paper-based conductive sensing layers by appropriate assembly and encapsulation. The stacked structure obviously increases the change and upper limit of contact area between sensing layers and electrodes, which effectively improves the sensitivity of the pressure sensor over the whole sensing range compared to single-layered structure. Thus, the sensor in this work shows high sensitivities (more than 300 kPa−1) in a wide sensing range (3.6-714.3 kPa), with a maximum value of 1431.7 kPa−1. This work provides a new strategy to design and fabricate piezoresistive pressure sensors with high sensitivity and wide sensing range.