    Measured and synthetic rigid head motion datasets via generative model for motion simulation and compensation in medical imaging

    by Manuela Goldmann, Felix Damm, Florian Goldmann, Oliver Hornung, Michael Manhart, Alexander Preuhs, Markus Kowarschik, Andreas Maier

    PurposeRigid head motion during interventional C-arm cone-beam CT (CBCT) is a major source of image degradation. Learning-based motion estimation requires realistic training data, but ground-truth motion is scarce, limiting direct validation of compensation trajectories. We address this gap with an open resource consisting of tracked real motion and pregenerated synthetic motion, along with a pretrained variational autoencoder (VAE) to generate larger ground-truth datasets.ApproachUsing stereo optical tracking, we recorded rigid 6-DoF head motion trajectories from 25 volunteers lying head-first supine on an examination table, resembling a clinical setting. After data preprocessing, we trained a VAE on 120 sequences of 10 s at 30 Hz. Motion is represented in patient-centered coordinates to support transformation to arbitrary scan geometries. Similarity between measured and generated data is assessed via distributional distances, correlation metrics, low-dimensional embeddings, and a posthoc analysis of the learned latent space.ResultsEvaluated based on 120 generated sequences, the trained VAE is capable of producing diverse 6-DoF trajectories that preserve real-world data correlation structure. Distributional and frequency-domain metrics, along with t-SNE embeddings, show overlap between real and synthetic samples without evidence of mode collapse or training data replication.ConclusionsThis work provides an openly released resource comprising measured trajectories, a synthetic dataset, and pretrained VAE weights together with full training and evaluation code, combining rigid 6-DoF head motion measured in a realistic C-arm setting with a retrainable generative model. It is intended to support reproducible development, benchmarking, and comparison of head motion estimation methods in medical imaging modalities.

  • Open Access

    Challenging Hounsfield Unit cutoffs: spectral thresholding for synthetic coronary plaque phantoms on photon-counting CT

    by Florian Goldmann, Michael Wels, Thomas Allmendinger, Manuela Goldmann, Ralf Gutjahr, Markus Jürgens, Jonas Neumann, Leonhard Rist, Karl Stierstorfer, Michael Sühling, et al.

    PurposeAssess whether photon-counting computed tomography (PCCT) improves discrimination of vulnerable coronary soft-plaque components by extending one-dimensional Hounsfield Unit (HU) thresholding to a simple, interpretable two-dimensional linear rule.ApproachWe generated a synthetic cohort of N=225 coronary plaque phantoms with randomized anatomy, tissue composition (lipid-rich, fibrotic, calcified), and iodine concentrations. Ultra–high-resolution PCCT data were reconstructed into polychromatic T3D, high energy threshold, material-specific, and virtual monoenergetic images (VMIs). Voxel-wise logistic regression implemented single-image (1D) and dual-image (2D) decision rules; performance was assessed by the area under the receiver operating characteristic curve (ROC-AUC). Partial-volume behavior was quantified as correctness versus Euclidean distance to the nearest out-of-class voxel using isotonic regression with a phantom-level bootstrap.ResultsCombining T3D with low-keV VMI yielded the best separation of lipid-rich and fibrous soft-plaque subtypes. A 2D linear rule on T3D + VMI50 achieved AUC=0.925 (95% CI: [0.912, 0.937]), exceeding 1D thresholding on T3D (AUC=0.850; 95% CI: [0.821, 0.875]) and on VMI50 (AUC=0.814; 95% CI: [0.780, 0.843]). Correctness increased with distance to the nearest out-of-class voxel and was ≥95% for voxels at distances D≥0.28 mm (lipid-rich) and D≥0.43 mm (fibrous) (lower 95% CI bounds: 0.20 and 0.41 mm). Accuracy degraded below these thresholds.ConclusionsA transparent, affine 2D threshold that combines routinely reconstructed PCCT images improves voxel-wise discrimination of lipid-rich versus fibrous plaque over conventional HU binning, yielding higher AUCs with tighter 95% confidence intervals. The derived boundary-distance guidance indicates where voxel-level decisions remain reliable, supporting interpretable, clinically pragmatic plaque assessment.

  • A Gradient-Based Approach to Fast and Accurate Head Motion Compensation in Cone-Beam CT

    by Mareike Thies, Fabian Wagner, Noah Maul, Haijun Yu, Manuela Goldmann, Linda-Sophie Schneider, Mingxuan Gu, Siyuan Mei, Lukas Folle, Alexander Preuhs, et al.

    Cone-beam computed tomography (CBCT) systems, with their flexibility, present a promising avenue for direct point-of-care medical imaging, particularly in critical scenarios such as acute stroke assessment. However, the integration of CBCT into clinical workflows faces challenges, primarily linked to long scan duration resulting in patient motion during scanning and leading to image quality degradation in the reconstructed volumes. This paper introduces a novel approach to CBCT motion estimation using a gradient-based optimization algorithm, which leverages generalized derivatives of the backprojection operator for cone-beam CT geometries. Building on that, a fully differentiable target function is formulated which grades the quality of the current motion estimate in reconstruction space. We drastically accelerate motion estimation yielding a 19-fold speed-up compared to existing methods. Additionally, we investigate the architecture of networks used for quality metric regression and propose predicting voxel-wise quality maps, favoring autoencoder-like architectures over contracting ones. This modification improves gradient flow, leading to more accurate motion estimation. The presented method is evaluated through realistic experiments on head anatomy. It achieves a reduction in reprojection error from an initial average of 3 mm to 0.61 mm after motion compensation and consistently demonstrates superior performance compared to existing approaches. The analytic Jacobian for the backprojection operation, which is at the core of the proposed method, is made publicly available. In summary, this paper contributes to the advancement of CBCT integration into clinical workflows by proposing a robust motion estimation approach that enhances efficiency and accuracy, addressing critical challenges in time-sensitive scenarios.