Omer Berkay Bayraktar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Omer Berkay Bayraktar has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Bora Uzun
Department of Biomechanics, Dokuz Eylül University, İzmir, Turkey
1 shared publication - Cemal Kazimoglu
Department of Orthopaedics and Traumatology, Izmir Katip Celebi University, Izmir, Turkey
1 shared publication Ihsan Akan
Department of Orthopaedics and Traumatology, Izmir Katip Celebi University, Izmir, Turkey
1 shared publication- Mehmet Maden
Department of Orthopaedics and Traumatology, Faculty of Medicine, Ataturk Training and Research Hospital, Izmir Katip Celebi University, Izmir, Turkey
1 shared publication - Tayfun Bacaksız
Department of Orthopaedics and Traumatology, Izmir Katip Celebi University, Izmir, Turkey
1 shared publication
Latest Publications
- Open Access
- 7 February 2025
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 20 (1) , 1-9
Does protruding headless cannulated screw reduce fixation stability in tension band wiring technique for patella fractures? a biomechanical study
The selection of an implant is a critical factor in the surgical treatment of patella fractures due to the risk of various complications, such as non-union, implant failure, and irritation. The present study evaluated and compared the biomechanical strength of headless cannulated screws about screw length using the tension band wiring technique. Forty-eight sawbone patellas with transverse fractures were divided into three fixation groups based on the screw length used in tension band wiring. Overall, three different fixation groups were determined: Group 1 (recessed headless cannulated screw fixation), Group 2 (full-length headless cannulated screw fixation), and Group 3 (protruding headless cannulated screw fixation). A setup was used to simulate a knee with a flexion angle of 60 degrees. Specimens underwent biomechanical testing under axial traction (static test) and cyclic loading (dynamic test). Displacements at 300 Newtons (N), loads at 2 millimetres (mm) displacement, and failure loads were documented for each sample in the static test. In the dynamic test protocol, 10,000 repetitive cycles were performed under physiological load between 100 and 300 N, and final displacements were recorded. There were significant differences in the loads achieved at 2 mm displacement levels, and Group 3 demonstrated lower force values compared to other constructs in the static test (P = 0.003). All groups revealed similar displacements at 300 N and failure load values under axial traction. In the dynamic test, Group 3 had significantly higher fracture displacement under cyclic loading compared to the other specimens (P = 0.006). This study found headless cannulated screws for transverse patella fracture fixation provide sufficient stability; however, protruding headless screws reduce the fixation strength. Recessed or full-length screws may improve stability and bony healing, potentially preventing complications in patella fractures. Biomechanical study N/A.
- 7 February 2025
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 20 (1) , 1-9
Open AccessDoes protruding headless cannulated screw reduce fixation stability in tension band wiring technique for patella fractures? a biomechanical study
The selection of an implant is a critical factor in the surgical treatment of patella fractures due to the risk of various complications, such as non-union, implant failure, and irritation. The present study evaluated and compared the biomechanical strength of headless cannulated screws about screw length using the tension band wiring technique. Forty-eight sawbone patellas with transverse fractures were divided into three fixation groups based on the screw length used in tension band wiring. Overall, three different fixation groups were determined: Group 1 (recessed headless cannulated screw fixation), Group 2 (full-length headless cannulated screw fixation), and Group 3 (protruding headless cannulated screw fixation). A setup was used to simulate a knee with a flexion angle of 60 degrees. Specimens underwent biomechanical testing under axial traction (static test) and cyclic loading (dynamic test). Displacements at 300 Newtons (N), loads at 2 millimetres (mm) displacement, and failure loads were documented for each sample in the static test. In the dynamic test protocol, 10,000 repetitive cycles were performed under physiological load between 100 and 300 N, and final displacements were recorded. There were significant differences in the loads achieved at 2 mm displacement levels, and Group 3 demonstrated lower force values compared to other constructs in the static test (P = 0.003). All groups revealed similar displacements at 300 N and failure load values under axial traction. In the dynamic test, Group 3 had significantly higher fracture displacement under cyclic loading compared to the other specimens (P = 0.006). This study found headless cannulated screws for transverse patella fracture fixation provide sufficient stability; however, protruding headless screws reduce the fixation strength. Recessed or full-length screws may improve stability and bony healing, potentially preventing complications in patella fractures. Biomechanical study N/A.