Yong-Won Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yong-Won Kim has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Eun-Ha Park
School of Advanced Materials Science and Engineering, Sungkyunkwan University, Suwon-si, Gyeonggi-do 16419, Republic of Korea
2 shared publications - Jung-Gu Kim
Sungkyunkwan University
2 shared publications Byung-Su Kim
Electrification Corrosion Control Research Laboratory, Hyundai Motors Company, Hwaseong-si, Gyeonggi-do, Republic of Korea
1 shared publication- Geon-Il Kim
School of Advanced Materials Science and Engineering, Sungkyunkwan University College of Engineering, Suwon-si, Republic of Korea, 16419
1 shared publication - Jeong-Min Lim
School of Advanced Materials Science and Engineering, Sungkyunkwan University, Suwon-si, Gyeonggi-do, Republic of Korea
1 shared publication Seung-Ho Ahn
Electrification Corrosion Control Research Laboratory, Hyundai Motors Company, Hwaseong-si, Gyeonggi-do, Republic of Korea
1 shared publication
Latest Publications
- 26 February 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (4) , 041502
Corrosion-Resistant Aluminum Alloy Design Strategy Using Combination of Galvanostatic Test and Quadratic Regression Analysis
This study focuses on the design and evaluation of corrosion-resistant aluminum alloys using galvanostatic test and quadratic regression analysis. Al-Zr and Al-Mn-Zr alloys were evaluated through both galvanostatic and immersion tests. The galvanostatic test effectively simulated localized corrosion mechanisms, reducing testing duration from hundreds or thousands of hours to just tens of hours. Scanning Kelvin probe force microscopy and scanning electron microscopy/energy-dispersive spectroscopy analyses revealed that alloys with higher potential differences between precipitates and the Al matrix showed increased susceptibility to localized corrosion. A quadratic regression model was developed to describe the relationship between maximum pit depth and the contents of Zr and Mn, achieving a high coefficient of determination (R 2 = 0.975). The model identified an optimal alloy composition of 0.16 wt% Zr and 0.41 wt% Mn, resulting in a minimized pit depth of 24.40 μm. This research demonstrates that combining the galvanostatic test with regression analysis shortens the required time for development of corrosion-resistant aluminum alloys, providing a framework for optimizing compositions and predicting corrosion resistance.
- 26 February 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (4) , 041502
Corrosion-Resistant Aluminum Alloy Design Strategy Using Combination of Galvanostatic Test and Quadratic Regression Analysis
This study focuses on the design and evaluation of corrosion-resistant aluminum alloys using galvanostatic test and quadratic regression analysis. Al-Zr and Al-Mn-Zr alloys were evaluated through both galvanostatic and immersion tests. The galvanostatic test effectively simulated localized corrosion mechanisms, reducing testing duration from hundreds or thousands of hours to just tens of hours. Scanning Kelvin probe force microscopy and scanning electron microscopy/energy-dispersive spectroscopy analyses revealed that alloys with higher potential differences between precipitates and the Al matrix showed increased susceptibility to localized corrosion. A quadratic regression model was developed to describe the relationship between maximum pit depth and the contents of Zr and Mn, achieving a high coefficient of determination (R 2 = 0.975). The model identified an optimal alloy composition of 0.16 wt% Zr and 0.41 wt% Mn, resulting in a minimized pit depth of 24.40 μm. This research demonstrates that combining the galvanostatic test with regression analysis shortens the required time for development of corrosion-resistant aluminum alloys, providing a framework for optimizing compositions and predicting corrosion resistance.
- 22 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (1) , 1324-1331
Effect of Current Flow on the Galvanic Corrosion in Electrical Parts of Electric Vehicles
In this study, the effect of current flow through electrical parts on galvanic corrosion behavior was investigated. To predict the corrosion rate of galvanic coupled electrical parts, an equivalent circuit was constructed, encompassing both galvanic and external currents. Following the circuit, the corrosion current equation was formulated based on Kirchhoff’s law, which consists of the following parameters: external current, solution resistance, contact resistance, and galvanic cell voltage. To validate the formula, calculated mass loss was compared with the experimental mass loss after one week of immersion tests. According to the corrosion current formula, the contact resistance and galvanic cell voltage between the galvanic coupled materials should be minimized to reduce the corrosion failure of electrical parts.
- 22 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (1) , 1324-1331
Effect of Current Flow on the Galvanic Corrosion in Electrical Parts of Electric Vehicles
In this study, the effect of current flow through electrical parts on galvanic corrosion behavior was investigated. To predict the corrosion rate of galvanic coupled electrical parts, an equivalent circuit was constructed, encompassing both galvanic and external currents. Following the circuit, the corrosion current equation was formulated based on Kirchhoff’s law, which consists of the following parameters: external current, solution resistance, contact resistance, and galvanic cell voltage. To validate the formula, calculated mass loss was compared with the experimental mass loss after one week of immersion tests. According to the corrosion current formula, the contact resistance and galvanic cell voltage between the galvanic coupled materials should be minimized to reduce the corrosion failure of electrical parts.