GAGabriele Andreetta

Gabriele Andreetta

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gabriele Andreetta has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Two-regime degradation associated with carrier compensation and structural instability in NiO/ β -Ga2O3 heterojunction diodes under 1864 MeV Ta-ion irradiation

    by Xing Li, Silei Zhong, Yahui Feng, Yang Liu, Gabriele Andreetta, Rui Zhou, Huichao Hu, Xiaoning Zhang, Chao Peng, Hong Zhang, et al.

    We report a two-regime degradation behavior in NiO/β-Ga2O3 heterojunction diodes subjected to 1864 MeV Ta swift heavy ions (linear energy transfer in Si ≈ 75 MeV cm2/mg) over a fluence range from 1 × 108 to 1 × 1011 ions/cm2. At low fluences (≤1 × 109 ions/cm2), the devices retain rectification while exhibiting reduced forward current density (JF), increased specific on-resistance (Ron,sp), and enhanced reverse leakage current (JR), consistent with donor compensation in the β-Ga2O3 drift layer. Capacitance–voltage (C–V) analysis reveals a monotonic reduction in the net carrier concentration (Nnet) with carrier-removal rates (Rc) on the order of 107 cm−1, indicating a quasi-linear compensation regime. When the fluence approaches 1 × 1010 ions/cm2, rectification collapses and normal turn-on behavior is lost. The capacitance becomes weakly voltage dependent, suggesting deviation from linear compensation. Cross-sectional scanning transmission electron microscopy reveals densely distributed nanoscale latent tracks in the drift layer, while cross-sectional scanning electron microscopy shows pronounced ∼2 μm interfacial warping near the NiO/β-Ga2O3 junction. These results indicate a transition from a low-fluence quasi-linear carrier-compensation regime to a high-fluence failure regime associated with structural instability, where severe carrier compensation and failure-associated structural perturbations are both observed.

  • Open Access

    Effect of the Anti-Punchthrough Implant on the Total Ionizing Dose Response of Planar Silicon n-MOSFETs

    by Gabriele Andreetta, Giulio Borghello, Federico Faccio, Simone Gerardin, Marta Bagatin, Alessandro Paccagnella, Stefano Bonaldo

    The aggressive scaling of CMOS devices has led to a decreased sensitivity of the gate oxide to Total Ionizing Dose (TID) effects. Currently, the TID tolerance of scaled transistors is primarily related to charge trapping in other thick isolation oxides, such as Shallow Trench Isolations (STI). Moreover, to mitigate the short-channel effects, including the threshold voltage roll-off, drain-induced barrier lowering (DIBL), and punchthrough, modern technologies include non-uniform bulk doping profiles determined by halos and anti-punchthrough (APT) implants. These implants add complexity to the understanding of TID effects related to the charge trapping in the STI. In this work, we combined experimental results with TCAD simulations to highlight the key role of the APT implant in influencing the TID-sensitivity of planar MOSFETs. The results demonstrate that variation in the APT doping, depth, and width significantly impacts the off-leakage current, which is a major concern in irradiated n-MOSFETs. The highest TID tolerance is achieved in transistors designed with the APT implantation depth close to the drain/source extension depth, while the TID degradation of threshold voltage and transconductance is slightly affected by the APT. Notably, these changes in APT implantation parameters may not be evident in the pre-radiation characteristics but can substantially affect the TID resilience. As a result, transistors with different APT implantation profiles exhibit similar pre-rad ID-VGS but diverge in their TID sensitivities.

  • Open Access

    TID Effects in Vertical SiC Power MOSFETs Irradiated at Different Temperatures

    by Gabriele Andreetta, Corinna Martinella, Philipp Natzke, Marta Bagatin, Simone Gerardin, Serena Mattiazzo, Alessandro Paccagnella, Ulrike Grossner, Stefano Bonaldo

    The capability to operate at high temperature of SiC power MOSFETs makes it essential to assess radiation-induced damage under realistic operating conditions to ensure reliable evaluations of device robustness. This study investigates the total ionizing dose (TID) effects induced by X-rays at different temperatures in vertical SiC power MOSFETs. Irradiation at high temperatures results in smaller threshold voltage (VTH) degradation than at room temperature, due to enhanced recombination of positively trapped charge during exposure. Nonetheless, when high-temperature annealing is performed after the exposure, the final threshold voltage shift (ΔVTH) is independent of the irradiation temperature, and solely dependent on the temperature selected for the annealing process. The negligible degradation observed in subthreshold swing, transconductance, and C-V stretch-out indicates minimal activation of interface traps at the SiC/SiO2 interface, confirming improved interface quality in the latest generation devices.


  • Open Access

    Analog Design Implications of 500 Mrad Total Ionizing Dose in 28 nm HPC+ Bulk CMOS

    by L. Gelmi, G. Andreetta, E. A. Vallicelli, M. Tambaro, F. D’OTtavi, M. Chiariello, S. Bonaldo, S. Mattiazzo, A. Lai, M. De Matteis

  • Open Access

    TID Response Comparison of Two 28-nm CMOS Technology Flavors: HPL vs. HPC+

    by Gabriele Andreetta, Luca Gelmi, Elia Arturo Vallicelli, Marcello De Matteis, Adriano Lai, Alessandro Paccagnella, Serena Mattiazzo, Stefano Bonaldo

  • Open Access

    COTS BJT Radiation Qualification Methodology for Highly Distributed Systems in Mixed-Field Environments

    by Gabriele Andreetta, Rudy Ferraro, Alessandro Zimmaro, Stefano Bonaldo, Alessandro Paccagnella, Yves Thurel, Alessandro Masi, Salvatore Danzeca

    Commercial-off-the-shelf Bipolar Junction Transistors (BJTs) are commonly used in critical radiation-tolerant electronic systems, making their radiation qualification essential to ensure compliance with project-specific radiation design requirements. Although the response of BJTs to radiation is well-documented, their sensitivity to Total Ionizing Dose (TID) and Displacement Damage (DD) can complicate their qualification for systems exposed to diverse radiation environments, such as high-energy particle accelerators. This work investigates the primary degradation mechanisms in various BJTs used in CERN electronics, where devices are exposed to neutron-rich and charged particle environments. This research supports the adaptation of qualification strategies, ensuring a more reliable prediction of BJT degradation in complex radiation environments. The paper also provides examples of system response estimations and highlights the impact of various degradation mechanisms, such as lot-to-lot variations, Enhanced Low Dose Rate Effects (ELDRS), and how the relative dominance of TID or DD effects can differently affect both system performance and the qualification process.