Luca Gelmi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Luca Gelmi has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Elia Arturo Vallicelli
Department of Physics, University of Milano-Bicocca, 20126 Milano, Italy
3 shared publications - Marcello De Matteis
University of Milano-Bicocca
3 shared publications - Fabio D'OTtavi
University of Milano-Bicocca
2 shared publications - Gabriele Andreetta
Department of Information Engineering, University of Padova, Padua, Italy
2 shared publications - Matteo Chiariello
University of Milano Bicocca, piazza della Scienza 3
2 shared publications - Mattia Tambaro
Department of Physics, University of Milano-Bicocca, 20126 Milano, Italy
2 shared publications
Latest Publications
- Open Access
- 1 May 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (05) , C05012
28 nm MOS transistor SPICE BSIM model for simulating electrical effects of 1-Grad Total Ionizing Dose based on gate oxide capacitance
Circuit-level SPICE analysis of analog blocks in 28-nm bulk CMOS at doses approaching 1 Grad remains under-served. Device-centric characterizations and charge-based formalisms developed within TCAD rarely propagate into production EDA flows, leaving a lack of compact, SPICE-deployable models that represent radiation-induced degradation with sufficient fidelity and workflow alignment. BSIM RAD is proposed as a compact model base on BSIM that encapsulates Total Ionizing Dose damage by recasting oxide- and interface-trap contributions into an effective gate-oxide capacitance per unit area (C^'OX). The implementation is native to Cadence Virtuoso/Spectre, enabling drop-in use within standard verification setups. Calibration against measurements from 0 rad to 1 Grad covers nMOS/pMOS devices across distinct W/L sets and multiple V_DS values. Across this device matrix, the model reproduces the fractional shift in V_TH with sub-percent error and matches irradiated I_DS-V_GS characteristics within 2σ of the data, preserving the polarity-dependent displacement. The approach captures TID behavior to 1 Grad and beyond while maintaining parameter identifiability and CAD/EDA portability, closing a practical gap for global SPICE verification of radiation-tolerant analog circuits in 28-nm CMOS.
- 1 May 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (05) , C05012
Open Access28 nm MOS transistor SPICE BSIM model for simulating electrical effects of 1-Grad Total Ionizing Dose based on gate oxide capacitance
Circuit-level SPICE analysis of analog blocks in 28-nm bulk CMOS at doses approaching 1 Grad remains under-served. Device-centric characterizations and charge-based formalisms developed within TCAD rarely propagate into production EDA flows, leaving a lack of compact, SPICE-deployable models that represent radiation-induced degradation with sufficient fidelity and workflow alignment. BSIM RAD is proposed as a compact model base on BSIM that encapsulates Total Ionizing Dose damage by recasting oxide- and interface-trap contributions into an effective gate-oxide capacitance per unit area (C^'OX). The implementation is native to Cadence Virtuoso/Spectre, enabling drop-in use within standard verification setups. Calibration against measurements from 0 rad to 1 Grad covers nMOS/pMOS devices across distinct W/L sets and multiple V_DS values. Across this device matrix, the model reproduces the fractional shift in V_TH with sub-percent error and matches irradiated I_DS-V_GS characteristics within 2σ of the data, preserving the polarity-dependent displacement. The approach captures TID behavior to 1 Grad and beyond while maintaining parameter identifiability and CAD/EDA portability, closing a practical gap for global SPICE verification of radiation-tolerant analog circuits in 28-nm CMOS.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- p. 1
Analog Design Implications of 500 Mrad Total Ionizing Dose in 28 nm HPC+ Bulk CMOS
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- p. 1
Open AccessAnalog Design Implications of 500 Mrad Total Ionizing Dose in 28 nm HPC+ Bulk CMOS
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- p. 1
TID Response Comparison of Two 28-nm CMOS Technology Flavors: HPL vs. HPC+
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- p. 1
Open AccessTID Response Comparison of Two 28-nm CMOS Technology Flavors: HPL vs. HPC+