TMThomas Marth

Thomas Marth

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Thomas Marth has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Metal Artifact Reduction in Lumbar Spine Instrumentation

    by Thomas Marth, Adrian Alexander Marth, Frederik Abel, Roy Paul Marcus, Benjamin Fritz, Andreas Specovius, Christoph J. Laux, Daniel Nanz, Reto Sutter

    Objective: Photon-counting detector (PCD) computed tomography (CT) systems allow the reconstruction of virtual monoenergetic images (VMIs) from inherently available spectral data. However, qualitative and quantitative evaluations of VMI in combination with tin-prefiltration (Sn) and iterative metal artifact reduction (iMAR), as well as their comparison to energy-integrating detector (EID) CT, are limited; therefore, the objective was to compare their performance qualitatively and quantitatively in the setting of lumbar spine instrumentation. Materials and Methods: Retrospectively, 100 clinical Sn CT scans after lumbar spine fusion surgery (50 EID and 50 PCD) were analyzed. Metal artifacts were quantitatively and qualitatively assessed in EID standard (EID std ), PCD standard (PCD std ), and PCD VMI at 120 keV (PCD VMI120 ), PCD iMAR (PCD iMAR ), and combined PCD VMI at 120 keV + iMAR (PCD VMI120+iMAR ). Regions of interest were placed in the most hyperdense and hypodense areas near metal artifacts, and the attenuation and SD/noise (SD) of Hounsfield Units (HU) were assessed as a quantitative artifact surrogate. For qualitative evaluation, 2 independent readers rated 6 image features on a 4-point Likert Scale. Results: Seventy-four patients were included, of whom 26 underwent both an EID and a PCD CT. Radiation doses were significantly lower ( P < 0.01) for PCD CT [median CTDIvol of 6.4 mGy (4.6 to 8.4)] compared with EID CT [median CTDI vol of 12.5 mGy (11.1 to 13.7)]. Hypodense artifact attenuation was significantly reduced ( P < 0.01) with PCD iMAR (HU -260), PCD VMI120 (-176), and PCD VMI120+IMAR (-60) compared with EID std (-626). Hyperdense artifact attenuation was significantly reduced ( P < 0.01) in PCD VMI120 (HU 103) and PCD VMI120+IMAR (-1) compared with EID std (577). Qualitative artifact extent was rated significantly less severe in PCD iMAR and PCD VMI120+iMAR images compared with EID std ( P ≤ 0.01), while trabecular and cortical bone visibility was rated lower in PCD iMAR (2.73) and PCD VMI120 (2.63), P < 0.01, and lowest in PCD VMI120+iMAR (1.82) compared with EID std (3.19), P < 0.01. Significantly ( P < 0.01) more silhouette artifacts were present in the 100 kVp subgroup compared with the 140 kVp subgroup in PCD VMI120 and PCD VMI120+iMAR , and significantly ( P < 0.01) more dark zone artifacts in the PCD VMI120 series at 100 kVp compared with 140 kVp. Conclusion: PCD CT with VMI 120 or iMAR achieved artifact reduction comparable to EID CT for lumbar spine metal artifact reduction, at nearly half the radiation dose. Combining VMI120 + iMAR provided the strongest qualitative and quantitative artifact reduction, but at the cost of the lowest cortical and trabecular bone visibility. 140 kVp acquisitions should be favored over 100 kVp acquisitions in PCD to reduce the occurrence of “dark zone” and “silhouette artifacts”, suggesting a fixed tube voltage instead of an automatic tube voltage setting in instrumented lumbar spine imaging. VMI reconstruction of tin-filtered lumbar spine CT effectively reduces metal artifacts, with PCD favored over EID for its inherent spectral capabilities and the potential for substantial dose reduction.


  • Open Access

    Impact of calcium suppression imaging on hand and wrist fracture detection in spectral CT: a comparison with X-ray and CT

    by Thomas Marth, Franziska Adomat, Fides R. Schwartz, Tim S. Fischer, Reto Sutter, Anna L. Falkowski

    Objectives To evaluate the impact of calcium suppression (CaSupp) imaging of spectral computed tomography (SpCT) on fracture detection in clinical routine in the acute trauma setting of the hand and wrist. Materials and methods Retrospective inclusion of 125 patients who underwent both X-ray and SpCT examinations of the hand and wrist in an acute trauma setting. Two independent readers evaluated fracture presence on X-ray, conventional CT, and conventional CT plus CaSupp images (time interval 4 weeks, each). Bone bruise (BBr) presence was evaluated on CaSupp images. Sensitivity and specificity were calculated according to the consensus reading as the reference standard. Results Of the 125 patients (mean age, 55 years ± 19.5 [SD]; 67 female), 120 presented with at least one fracture, for a total of 212 fractured bones. Sensitivity was increased significantly for both readers in CT + CaSupp (94.3 and 97.2%) compared to conventional CT (88.2 and 90.1%, p < .01) and X-ray (72.6 and 75.9%, p < .01). Specificity was 99.9 and 100% for CT + CaSupp, 99.8 and 99.9% for conventional CT, and 99.4 and 99.9% for X-ray. Reader 1 detected 13 additional fractures in CT + CaSupp compared to conventional CT alone, while Reader 2 detected 15 additional fractures. BBr was seen in 58% of all fractures, in 76% of multifragmentary fractures, and in 13% of avulsion fractures. Inter-reader κ was almost perfect for X-ray (κ = .85), CT and CT + CaSupp (κ = .95), and substantial for BBr (κ = .61). Conclusion CaSupp images in combination with conventional CT images significantly improved sensitivity for acute trauma fracture detection in the hand and wrist compared to conventional CT images alone and X-ray.

  • Open Access

    Established acetabular radiological reference values can be reliably transferred to reconstructed parallel-beam 2D images from ultra-low-dose pelvic CT

    by Arnaud Klopfenstein, Thomas Marth, Stefan Sommer, Reto Sutter, Patrick O. Zingg, Dominik Kaiser

  • Open Access

    Medial unicompartmental knee arthroplasties: Radiographic findings associated with conversion to total knee arthroplasty – A Case control study

    by Anna L. Falkowski, Christoph Germann, Céline Gfeller, Fides R. Schwartz, Thomas Marth, Sandro F. Fucentese, Stefan M. Zimmermann, Reto Sutter


  • Open Access

    Diagnostic value of a coronal STIR sequence in conjoined lumbar nerve root detection: an MRI accuracy study

    by Georg Wilhelm Kajdi, Thomas Marth, Jung-Ah Choi, Mazda Farshad, Reto Sutter

    Objectives: To assess diagnostic accuracy for conjoined lumbosacral nerve root (CLNR) detection on MRI when adding a coronal STIR sequence to the standard lumbar spine protocol. Materials and methods: In this retrospective study, two radiologists assessed the presence of CLNR and lumbosacral transitional vertebrae (LSTV), using a standard lumbar MRI protocol and an expanded protocol with an additional coronal STIR sequence. Prior radiologist consensus using the expanded protocol served as a reference standard for diagnosis. Results: In 751 patients (mean age 61.2 ± 15.7 years, 435 females), CLNR was found in 38 patients (5.1%) in consensus. Without coronal STIR, 13 CLNR patients were correctly identified, CLNR was missed in 25 patients, and 3 patients were falsely detected as having one (sensitivity of 34.2%, specificity of 99.6%, positive predictive value (PPV) of 81.3%, negative predictive value (NPV) of 96.6%, and accuracy of 96.3%). With coronal STIR, 31 CLNR patients were correctly identified, CLNR were missed in 7 patients, and one patient was falsely detected as having one (sensitivity of 81.6%, specificity of 99.9%, PPV of 96.9%, NPV of 99.0%, and accuracy of 98.9%). Inter-reader agreement improved from moderate without coronal STIR (κ = 0.592; 95% CI 0.38, 0.80) to almost perfect with coronal STIR (κ = 0.915; 95% CI 0.84, 0.99). LSTV had a prevalence of 13.3% among patients without and 26.3% among patients with CLNR (p = 0.025). Conclusion: Coronal STIR greatly improved sensitivity and inter-reader agreement for CLNR detection on MRI while slightly improving the specificity and accuracy. A significant association of CLNR and LSTV was found.


  • Open Access

    Implementing tin-prefiltration in routine clinical CT scans of the lower extremity: impact on radiation dose

    by Thomas Marth, Georg Wilhelm Kajdi, Christoph Stern, Reto Sutter

    Objectives: Several studies have demonstrated the potential of tin-prefiltration to reduce radiation dose while maintaining diagnostic image quality for musculoskeletal imaging. Still, no study has reported data on the impact of tin-prefiltration on radiation dose reduction for clinical routine scanning. Materials and methods: Retrospective inclusion of 300 clinically indicated CT scans of the pelvis, knee, and ankle before January 2020 (without tin filter) and after December 2020 (with tin filter). For each joint, 50 examinations with tin-prefiltration and 50 examinations without tin-prefiltration were selected. Dose parameters were extracted, calculated, and compared. Subjective and quantitative parameters for image quality were assessed. Results: The CTDIvol, DLP, and effective dose were reduced significantly in all tin-prefiltered examinations compared to the non-tin-prefiltered examinations (p < 0.001): CTDIvol was 65% lower in the pelvis, 73% lower in the knee, and 54% lower in the ankle. This reduced the effective dose of 61%, 71%, and 60%, respectively. In absolute numbers, the reduction of the median effective dose delivered in a single CT scan of the pelvis was − 2.29 mSv, − 0.15 mSv for the knee, and − 0.03 mSv for the ankle. No difference in diagnostic image quality, depiction of bone anatomy and soft tissues, and image artifacts was observed (p > 0.05). Subjective and objective image noise was higher in tin-prefiltered pelvis CT (p < 0.001). Conclusion: The implementation of tin-prefiltration in clinical routine scan protocols significantly reduced the effective radiation dose for unenhanced CT scans of the lower extremities between 60 and 70%.


  • Evaluating Undersampling Schemes and Deep Learning Reconstructions for High-Resolution 3D Double Echo Steady State Knee Imaging at 7 T: A Comparison Between GRAPPA, CAIPIRINHA, and Compressed Sensing

    by Thomas Dr. Med. Univ. Marth, Adrian Alexander Marth, Georg Wilhelm Kajdi, Marcel Dominik Nickel, Dominik Paul, Reto Sutter, Daniel Nanz, Constantin von Deuster

    Objective: The 3-dimensional (3D) double echo steady state (DESS) magnetic resonance imaging sequence can image knee cartilage with high, isotropic resolution, particularly at high and ultra-high field strengths. Advanced undersampling techniques with high acceleration factors can provide the short acquisition times required for clinical use. However, the optimal undersampling scheme and its limits are unknown. Materials and Methods: High-resolution isotropic (reconstructed voxel size: 0.3 × 0.3 × 0.3 mm3) 3D DESS images of 40 knees in 20 volunteers were acquired at 7 T with varying undersampling factors (R = 4–30) and schemes (regular: GRAPPA, CAIPIRINHA; incoherent: compressed sensing [CS]), whereas the remaining imaging parameters were kept constant. All imaging data were reconstructed with deep learning (DL) algorithms. Three readers rated image quality on a 4-point Likert scale. Four-fold accelerated GRAPPA was used as reference standard. Incidental cartilage lesions were graded on a modified Whole-Organ Magnetic Resonance Imaging Score (WORMS). Friedman's analysis of variance characterized rating differences. The interreader agreement was assessed using κ statistics. Results: The quality of 16-fold accelerated CS images was not rated significantly different from that of 4-fold accelerated GRAPPA and 8-fold accelerated CAIPIRINHA images, whereas the corresponding data were acquired 4.5 and 2 times faster (01:12 min:s) than in 4-fold accelerated GRAPPA (5:22 min:s) and 8-fold accelerated CAIPIRINHA (2:22 min:s) acquisitions, respectively. Interreader agreement for incidental cartilage lesions was almost perfect for 4-fold accelerated GRAPPA (κ = 0.91), 8-fold accelerated CAIPIRINHA (κ = 0.86), and 8- to 16-fold accelerated CS (κ = 0.91). Conclusions: Our results suggest significant advantages of incoherent versus regular undersampling patterns for high-resolution 3D DESS cartilage imaging with high acceleration factors. The combination of CS undersampling with DL reconstruction enables fast, isotropic, high-resolution acquisitions without apparent impairment of image quality. Since DESS specific absorption rate values tend to be moderate, CS DESS with DL reconstruction promises potential for high-resolution assessment of cartilage morphology and other musculoskeletal anatomies at 7 T.


  • Tendon Anatomy and Tendon Disorders of the Wrist

    by Thomas Marth, Nadja A. Grob, Jon A. Jacobson, Nadja Zechmann, Roman Guggenberger, Anna L. Falkowski

    Wrist pain is common and can be attributed to tendon pathologies.This review aims to give a structured review of tendon anatomy, discuss anatomical pitfalls, and provide an overview of typical tendon pathologies of the wrist based on the current literature.Typical tendon pathologies of the wrist include de Quervain tenosynovitis, proximal and distal intersection syndrome, extensor and flexor pollicis longus tendon ruptures, and extensor carpi ulnaris subsheath injury. Typical pitfalls are multiple bundles of the abductor pollicis longus tendon or the centrally increased signal of the extensor carpi ulnaris tendon.Both ultrasound and MRI are appropriate modalities for assessing the tendons of the wrist. Knowledge of normal anatomy, variants, pathologies, as well as appropriate imaging is crucial to determine the diagnosis.