Yin Qing
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yin Qing has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Lu Wang
State Key Laboratory of Deep Earth Exploration and Imaging, School of Engineering and Technology, China University of Geosciences, Beijing 100083, China
4 shared publications - Yutong Zu
State Key Laboratory of Deep Earth Exploration and Imaging, School of Engineering and Technology, China University of Geosciences, Beijing 100083, China
3 shared publications - Lingda Hu
State Key Laboratory of Deep Earth Exploration and Imaging, School of Engineering and Technology, China University of Geosciences, Beijing 100083, China
2 shared publications - Yuanbiao Hu
State Key Laboratory of Deep Earth Exploration and Imaging, School of Engineering and Technology, China University of Geosciences, Beijing 100083, China
2 shared publications - Di Qiu
School of Engineering and Technology, China University of Geosciences, Beijing 100083, China
1 shared publication - Penghui Wu
State Key Laboratory of Deep Earth Exploration and Imaging, School of Engineering and Technology, China University of Geosciences, Beijing 100083, China
1 shared publication
Latest Publications
- Open Access
Bent-Sub Parameter Design for Slim-Hole Push-the-Bit Guided Coring Tools: Trade-Off Between Build-Up Capability and Structural Response
The bent sub is a main deflection component in the near-bit assembly of small-diameter push-the-bit guided coring tools, and its parameters affect build-up capability and local structural response. Existing studies mainly focus on conventional rotary steerable drilling systems, whereas slim-hole constraints, including narrow annular clearance and cross-sectional weakening induced by internal coring channels, remain insufficiently considered. To address this problem, a static bending model of the near-bit section was established based on Euler–Bernoulli beam theory. Channel-induced cross-sectional weakening was represented using the actual concentric annular geometry of the primary load-bearing outer tube, and the bent-sub initial curvature, dual push-the-bit loads, axial weight on bit, and borehole-wall contact and friction effects were incorporated. The build-up rate (BUR), maximum equivalent stress, and maximum curvature served as response indicators. A control-variable approach was used to analyze the bent-sub length Lb, bend angle γ, and distance from the bit Db. The results showed that Db had the strongest effect on BUR, and all parameters exhibited a trade-off between steering performance and structural safety. Increasing Lb from 0.30 m to 0.80 m reduced BUR from 12.65°/30 m to 9.79°/30 m, whereas increasing γ from 0.5° to 2.5° increased BUR from 4.12°/30 m to 10.70°/30 m. Considering structural constraints and normalized BUR retention, the recommended engineering ranges are Lb = 0.65–0.80 m, γ = 1.3°–1.9°, and Db = 0.50–0.70 m.
Open AccessBent-Sub Parameter Design for Slim-Hole Push-the-Bit Guided Coring Tools: Trade-Off Between Build-Up Capability and Structural Response
The bent sub is a main deflection component in the near-bit assembly of small-diameter push-the-bit guided coring tools, and its parameters affect build-up capability and local structural response. Existing studies mainly focus on conventional rotary steerable drilling systems, whereas slim-hole constraints, including narrow annular clearance and cross-sectional weakening induced by internal coring channels, remain insufficiently considered. To address this problem, a static bending model of the near-bit section was established based on Euler–Bernoulli beam theory. Channel-induced cross-sectional weakening was represented using the actual concentric annular geometry of the primary load-bearing outer tube, and the bent-sub initial curvature, dual push-the-bit loads, axial weight on bit, and borehole-wall contact and friction effects were incorporated. The build-up rate (BUR), maximum equivalent stress, and maximum curvature served as response indicators. A control-variable approach was used to analyze the bent-sub length Lb, bend angle γ, and distance from the bit Db. The results showed that Db had the strongest effect on BUR, and all parameters exhibited a trade-off between steering performance and structural safety. Increasing Lb from 0.30 m to 0.80 m reduced BUR from 12.65°/30 m to 9.79°/30 m, whereas increasing γ from 0.5° to 2.5° increased BUR from 4.12°/30 m to 10.70°/30 m. Considering structural constraints and normalized BUR retention, the recommended engineering ranges are Lb = 0.65–0.80 m, γ = 1.3°–1.9°, and Db = 0.50–0.70 m.
- Open Access
- 18 December 2025
- Published by MDPI AG in Mathematics
- Vol. 13 (24) , 4029
Drilling Tool Attitude Dynamic Measurement Algorithm Based on Composite Inertial Measurement Unit
Drilling tool attitude parameters are crucial for achieving precise directional drilling and trajectory control. Navigation systems based on redundant micro-electro-mechanical systems inertial measurement units (MEMS-IMU) significantly improve the reliability and accuracy of drilling tool attitude measurements. To achieve redundant arrangement of MEMS-IMUs, this paper proposes uniformly arranging MEMS-IMUs on a hollow hexagonal prism carrier, taking into account the actual structure of the drilling tool. However, under dynamic conditions, when updating drilling tool attitude using the strapdown inertial navigation system (SINS), the nonlinear errors of the MEMS-IMU accumulate over time, leading to distortion in the attitude calculation results. Therefore, this paper proposes a composite inertial measurement unit (CIMU) attitude measurement method. A virtual inertial measurement unit (VIMU) is generated through multi-IMU data fusion. Furthermore, the geometric constraints between each IMU and the VIMU, combined with Kalman filtering, are used to achieve real-time suppression of attitude errors, thereby improving the accuracy of the drilling tool attitude calculation results. Experimental results show that, compared with conventional data fusion methods, the CIMU algorithm reduces the overall drilling tool attitude error level by 40–70%.
- 18 December 2025
- Published by MDPI AG in Mathematics
- Vol. 13 (24) , 4029
Open AccessDrilling Tool Attitude Dynamic Measurement Algorithm Based on Composite Inertial Measurement Unit
Drilling tool attitude parameters are crucial for achieving precise directional drilling and trajectory control. Navigation systems based on redundant micro-electro-mechanical systems inertial measurement units (MEMS-IMU) significantly improve the reliability and accuracy of drilling tool attitude measurements. To achieve redundant arrangement of MEMS-IMUs, this paper proposes uniformly arranging MEMS-IMUs on a hollow hexagonal prism carrier, taking into account the actual structure of the drilling tool. However, under dynamic conditions, when updating drilling tool attitude using the strapdown inertial navigation system (SINS), the nonlinear errors of the MEMS-IMU accumulate over time, leading to distortion in the attitude calculation results. Therefore, this paper proposes a composite inertial measurement unit (CIMU) attitude measurement method. A virtual inertial measurement unit (VIMU) is generated through multi-IMU data fusion. Furthermore, the geometric constraints between each IMU and the VIMU, combined with Kalman filtering, are used to achieve real-time suppression of attitude errors, thereby improving the accuracy of the drilling tool attitude calculation results. Experimental results show that, compared with conventional data fusion methods, the CIMU algorithm reduces the overall drilling tool attitude error level by 40–70%.
- Open Access
- 28 March 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (4) , 391
Installation Error Calibration Method for Redundant MEMS-IMU MWD
For Measurement While Drilling (MWD), the redundant Micro-Electro-Mechanical Systems Inertial Measurement Unit (MEMS-IMU) navigation system significantly enhances the reliability and accuracy of drill string attitude measurements. Such an enhancement enables precise control of the wellbore trajectory and enhances the overall quality of drilling operations. But installation errors of the redundant MEMS-IMUs still degrade the accuracy of drill string attitude measurements. It is essential to calibrate these errors to ensure measurement precision. Currently, the commonly used calibration method involves mounting the carrier on a horizontal plane and performing calibration through rotation. However, when the carrier rotates on the horizontal plane, the gravity acceleration component sensed by the horizontal axis of the IMU accelerometer in the carrier is very small, which leads to a low signal-to-noise ratio, so that the measured matrix obtained by the solution is dominated by noise. As a result, the accuracy of the installation is insufficient, and, finally, the effectiveness of the installation error compensation is reduced. In order to solve this problem, this study proposes a 45°-inclined six-position calibration method based on the selected hexagonal prism redundant structure for redundant MEMS-IMUs in MWD. Firstly, the compensation matrices and accelerometer measurement errors were analyzed, and the new calibration method was proposed; the carrier of the IMUs should be installed at an inclined position of 45°. Then, six measuring points were identified for the proposed calibration approach. Finally, simulation and laboratory experiments were conducted to verify the effectiveness of the proposed method. The simulation results showed that the proposed method reduced installation errors by 40.4% compared with conventional methods. The experiments’ results demonstrated reductions of 83% and 68% in absolute measurement errors for the x and y axes, respectively. As a result, sensor accuracy after compensation improved by over 25% compared with traditional methods. The calibration method proposed by this study effectively improves the accuracy of redundant systems, providing a new approach for the precise measurement of downhole trajectories.
- 28 March 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (4) , 391
Open AccessInstallation Error Calibration Method for Redundant MEMS-IMU MWD
For Measurement While Drilling (MWD), the redundant Micro-Electro-Mechanical Systems Inertial Measurement Unit (MEMS-IMU) navigation system significantly enhances the reliability and accuracy of drill string attitude measurements. Such an enhancement enables precise control of the wellbore trajectory and enhances the overall quality of drilling operations. But installation errors of the redundant MEMS-IMUs still degrade the accuracy of drill string attitude measurements. It is essential to calibrate these errors to ensure measurement precision. Currently, the commonly used calibration method involves mounting the carrier on a horizontal plane and performing calibration through rotation. However, when the carrier rotates on the horizontal plane, the gravity acceleration component sensed by the horizontal axis of the IMU accelerometer in the carrier is very small, which leads to a low signal-to-noise ratio, so that the measured matrix obtained by the solution is dominated by noise. As a result, the accuracy of the installation is insufficient, and, finally, the effectiveness of the installation error compensation is reduced. In order to solve this problem, this study proposes a 45°-inclined six-position calibration method based on the selected hexagonal prism redundant structure for redundant MEMS-IMUs in MWD. Firstly, the compensation matrices and accelerometer measurement errors were analyzed, and the new calibration method was proposed; the carrier of the IMUs should be installed at an inclined position of 45°. Then, six measuring points were identified for the proposed calibration approach. Finally, simulation and laboratory experiments were conducted to verify the effectiveness of the proposed method. The simulation results showed that the proposed method reduced installation errors by 40.4% compared with conventional methods. The experiments’ results demonstrated reductions of 83% and 68% in absolute measurement errors for the x and y axes, respectively. As a result, sensor accuracy after compensation improved by over 25% compared with traditional methods. The calibration method proposed by this study effectively improves the accuracy of redundant systems, providing a new approach for the precise measurement of downhole trajectories.
- Open Access
- 18 February 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (4) , 2137
The Development of the Pipe Jacking Guidance Technology
Pipe jacking is one of the most important construction methods in trenchless technology. Pipe jacking guidance technology acquires the jacking route by collecting the attitude and position information of the pipe jacking machine. It ensures that the deviation between the jacking route and the route designed in the engineering drawings during the construction is kept within the error range and prevents the damage to other facilities caused by the deviation of the construction route. It improves the construction efficiency and ensures the precision and safety of pipeline laying. In this paper, the basic principle and working mode of the pipe jacking guidance system are sorted out, and the current technical means are classified and organized. A systematic overview of the research on pipe jacking guidance methods is given, the development trend of pipe jacking guidance systems towards automation, intelligence and multi-source data fusion are discussed, and the challenges faced by pipe jacking guidance systems in complex scenarios are elaborated. This is to provide guidance and reference for the research and practice in related fields and to promote the further innovation and application of pipe jacking guidance technology.
- 18 February 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (4) , 2137
Open AccessThe Development of the Pipe Jacking Guidance Technology
Pipe jacking is one of the most important construction methods in trenchless technology. Pipe jacking guidance technology acquires the jacking route by collecting the attitude and position information of the pipe jacking machine. It ensures that the deviation between the jacking route and the route designed in the engineering drawings during the construction is kept within the error range and prevents the damage to other facilities caused by the deviation of the construction route. It improves the construction efficiency and ensures the precision and safety of pipeline laying. In this paper, the basic principle and working mode of the pipe jacking guidance system are sorted out, and the current technical means are classified and organized. A systematic overview of the research on pipe jacking guidance methods is given, the development trend of pipe jacking guidance systems towards automation, intelligence and multi-source data fusion are discussed, and the challenges faced by pipe jacking guidance systems in complex scenarios are elaborated. This is to provide guidance and reference for the research and practice in related fields and to promote the further innovation and application of pipe jacking guidance technology.