Abhishek Sharma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Abhishek Sharma has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Bhujanga Rao Nagulancha
Department of Chemistry, GITAM (Deemed to Be University) School of Science Hyderabad Telangana India
1 shared publication- Narasimha Swamy Lakka
Department of Chemistry, School of Applied Sciences and Humanities, VIGNAN’S Foundation for Science, Technology & Research, Vadlamudi, India
1 shared publication - Naresh Kumar Katari
School of Chemistry & Physics, College of Agriculture, Engineering & Science, Westville Campus University of KwaZulu‐Natal Durban South Africa
1 shared publication - Pedavenkatagari Narayana Reddy
Department of Chemistry, School of Science, GITAM Deemed to be University, Hyderabad, India
1 shared publication - Santhosh Kumar Ettaboina
Department of Chemistry Vignan's Foundation for Science Technology & Research Guntur Andhra Pradesh India
1 shared publication Satyasree Nannapaneni
Department of Chemistry Vignan's Foundation for Science Technology & Research Guntur Andhra Pradesh India
1 shared publication
Latest Publications
- 31 March 2026
- Published by Wiley in Separation Science Plus
- Vol. 9 (4) , e70217
Ultra‐Sensitive and Green LC–MS/MS Method for Trace‐Level Determination of Nitrosamine Drug Substance‐Related Impurities in the Anti‐Diuretic Drug Furosemide
In recent years, the international pharmaceutical community has expressed heightened concern about the occurrence of nitrosamine impurities and nitrosamine drug substance‐related impurities (NDSRI), as these compounds are well recognized for their strong mutagenic activity in humans. Among the drugs of interest, furosemide, an anti‐diuretic drug, is one. Structural assessments of furosemide have revealed the potential for the formation of an NDSRI, specifically N‐nitroso‐furosemide (N‐FUR). According to the Carcinogenic Potency Categorization Approach, this impurity is classified as a Category 4 carcinogen, with an acceptable daily intake limit of 1500 ng/day. Given the elevated cancer risk associated with such impurities, the development of highly sensitive and selective quantitative analytical methodologies is imperative. In response to this need, a robust liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was established for the trace‐level quantification of N‐FUR. Chromatographic separation was achieved using a Kinetex C 18 (100 mm × 3.0 mm, 2.6 µm), maintained at 45°C. The mobile phase consisted of water and methanol, in a 50:50 (%, v/v) ratio with 0.1% trifluoroacetic acid, delivered at a flow rate of 0.5 mL/min. Detection was performed using a multiple reaction monitoring approach in electro spray ionization, Negative mode, transitions monitored at m / z 358.0 → 284. The method was rigorously validated in accordance with international regulatory guidelines and demonstrated excellent performance characteristics, confirming its suitability for routine analysis. This validated LC–MS/MS method has been successfully transferred to the quality control unit, enabling routine monitoring of nitrosamine impurities in furosemide formulations.
- 31 March 2026
- Published by Wiley in Separation Science Plus
- Vol. 9 (4) , e70217
Ultra‐Sensitive and Green LC–MS/MS Method for Trace‐Level Determination of Nitrosamine Drug Substance‐Related Impurities in the Anti‐Diuretic Drug Furosemide
In recent years, the international pharmaceutical community has expressed heightened concern about the occurrence of nitrosamine impurities and nitrosamine drug substance‐related impurities (NDSRI), as these compounds are well recognized for their strong mutagenic activity in humans. Among the drugs of interest, furosemide, an anti‐diuretic drug, is one. Structural assessments of furosemide have revealed the potential for the formation of an NDSRI, specifically N‐nitroso‐furosemide (N‐FUR). According to the Carcinogenic Potency Categorization Approach, this impurity is classified as a Category 4 carcinogen, with an acceptable daily intake limit of 1500 ng/day. Given the elevated cancer risk associated with such impurities, the development of highly sensitive and selective quantitative analytical methodologies is imperative. In response to this need, a robust liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was established for the trace‐level quantification of N‐FUR. Chromatographic separation was achieved using a Kinetex C 18 (100 mm × 3.0 mm, 2.6 µm), maintained at 45°C. The mobile phase consisted of water and methanol, in a 50:50 (%, v/v) ratio with 0.1% trifluoroacetic acid, delivered at a flow rate of 0.5 mL/min. Detection was performed using a multiple reaction monitoring approach in electro spray ionization, Negative mode, transitions monitored at m / z 358.0 → 284. The method was rigorously validated in accordance with international regulatory guidelines and demonstrated excellent performance characteristics, confirming its suitability for routine analysis. This validated LC–MS/MS method has been successfully transferred to the quality control unit, enabling routine monitoring of nitrosamine impurities in furosemide formulations.
- 10 February 2025
- Published by Wiley in Biomedical Chromatography
- Vol. 39 (3) , e70021
Separation and Quantitative Estimation of Pharmacopeial Organic Impurities, Process‐Related Impurities, and Degradation Products of the Anti‐Schizophrenia Drug Clozapine in Pharmaceutical Formulations by Using Stability‐Indicating HPLC Method
Clozapine is an antipsychotic medication primarily used to treat severe schizophrenia symptoms. This research aimed to develop and validate a reliable, rapid, and sensitive reverse‐phase high‐performance liquid chromatography (RP‐HPLC) method for measuring organic impurities in clozapine drug substances and products. The chromatographic separation was achieved using an Agilent Poroshell 120 EC‐C18 column with gradient elution, using mobile phases consisting of acetonitrile, methanol, pH 2.4 phosphate buffer, and ethanol. The method operated at a flow rate of 1.0 mL/min, with a 10‐μL injection volume, a column temperature of 35°C, and detection at 257 nm. Validation was performed according to ICH Q2(R2) guidelines and USP general chapter. The method demonstrated optimal resolution between adjacent peaks, with values greater than 1.5, and provided accurate estimations free from interference. Recovery and regression values ranged from 80.0% to 120.0%, with R2 values exceeding 0.9995. The quantification range spanned from the limit of quantification to 150% of the specification level. The stability‐indicating capability of the RP‐HPLC method was confirmed through forced degradation studies. This method has been successfully implemented in a quality control laboratory for real‐time analysis of clozapine drug substances and products.
- 10 February 2025
- Published by Wiley in Biomedical Chromatography
- Vol. 39 (3) , e70021
Separation and Quantitative Estimation of Pharmacopeial Organic Impurities, Process‐Related Impurities, and Degradation Products of the Anti‐Schizophrenia Drug Clozapine in Pharmaceutical Formulations by Using Stability‐Indicating HPLC Method
Clozapine is an antipsychotic medication primarily used to treat severe schizophrenia symptoms. This research aimed to develop and validate a reliable, rapid, and sensitive reverse‐phase high‐performance liquid chromatography (RP‐HPLC) method for measuring organic impurities in clozapine drug substances and products. The chromatographic separation was achieved using an Agilent Poroshell 120 EC‐C18 column with gradient elution, using mobile phases consisting of acetonitrile, methanol, pH 2.4 phosphate buffer, and ethanol. The method operated at a flow rate of 1.0 mL/min, with a 10‐μL injection volume, a column temperature of 35°C, and detection at 257 nm. Validation was performed according to ICH Q2(R2) guidelines and USP general chapter. The method demonstrated optimal resolution between adjacent peaks, with values greater than 1.5, and provided accurate estimations free from interference. Recovery and regression values ranged from 80.0% to 120.0%, with R2 values exceeding 0.9995. The quantification range spanned from the limit of quantification to 150% of the specification level. The stability‐indicating capability of the RP‐HPLC method was confirmed through forced degradation studies. This method has been successfully implemented in a quality control laboratory for real‐time analysis of clozapine drug substances and products.