Santhosh Kumar Ettaboina
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Santhosh Kumar Ettaboina has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Naresh Kumar Katari
School of Chemistry & Physics, College of Agriculture, Engineering & Science, Westville Campus University of KwaZulu‐Natal Durban South Africa
5 shared publications Satyasree Nannapaneni
Department of Chemistry Vignan's Foundation for Science Technology & Research Guntur Andhra Pradesh India
3 shared publicationsParvateesam Yenda
Department of Chemistry, School of Science GITAM Deemed to be University Hyderabad India
2 shared publications- Thirupathi Dongala
Quality control Aurex Laboratories LLC East Windsor New Jersey USA
2 shared publications - Abhishek Sharma
Department of Chemistry GITAM (Deemed to Be University) School of Science Hyderabad Telangana India
1 shared publication Balasubramanian Satheesh
Analytical Research and Development Slayback Pharma India LLP, Manjeera Trinity Corporate, JNTU Hyderabad India
1 shared publication
Latest Publications
- 31 March 2026
- Published by Wiley in Separation Science Plus
- Vol. 9 (4) , e70217
Ultra‐Sensitive and Green LC–MS/MS Method for Trace‐Level Determination of Nitrosamine Drug Substance‐Related Impurities in the Anti‐Diuretic Drug Furosemide
In recent years, the international pharmaceutical community has expressed heightened concern about the occurrence of nitrosamine impurities and nitrosamine drug substance‐related impurities (NDSRI), as these compounds are well recognized for their strong mutagenic activity in humans. Among the drugs of interest, furosemide, an anti‐diuretic drug, is one. Structural assessments of furosemide have revealed the potential for the formation of an NDSRI, specifically N‐nitroso‐furosemide (N‐FUR). According to the Carcinogenic Potency Categorization Approach, this impurity is classified as a Category 4 carcinogen, with an acceptable daily intake limit of 1500 ng/day. Given the elevated cancer risk associated with such impurities, the development of highly sensitive and selective quantitative analytical methodologies is imperative. In response to this need, a robust liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was established for the trace‐level quantification of N‐FUR. Chromatographic separation was achieved using a Kinetex C 18 (100 mm × 3.0 mm, 2.6 µm), maintained at 45°C. The mobile phase consisted of water and methanol, in a 50:50 (%, v/v) ratio with 0.1% trifluoroacetic acid, delivered at a flow rate of 0.5 mL/min. Detection was performed using a multiple reaction monitoring approach in electro spray ionization, Negative mode, transitions monitored at m / z 358.0 → 284. The method was rigorously validated in accordance with international regulatory guidelines and demonstrated excellent performance characteristics, confirming its suitability for routine analysis. This validated LC–MS/MS method has been successfully transferred to the quality control unit, enabling routine monitoring of nitrosamine impurities in furosemide formulations.
- 31 March 2026
- Published by Wiley in Separation Science Plus
- Vol. 9 (4) , e70217
Ultra‐Sensitive and Green LC–MS/MS Method for Trace‐Level Determination of Nitrosamine Drug Substance‐Related Impurities in the Anti‐Diuretic Drug Furosemide
In recent years, the international pharmaceutical community has expressed heightened concern about the occurrence of nitrosamine impurities and nitrosamine drug substance‐related impurities (NDSRI), as these compounds are well recognized for their strong mutagenic activity in humans. Among the drugs of interest, furosemide, an anti‐diuretic drug, is one. Structural assessments of furosemide have revealed the potential for the formation of an NDSRI, specifically N‐nitroso‐furosemide (N‐FUR). According to the Carcinogenic Potency Categorization Approach, this impurity is classified as a Category 4 carcinogen, with an acceptable daily intake limit of 1500 ng/day. Given the elevated cancer risk associated with such impurities, the development of highly sensitive and selective quantitative analytical methodologies is imperative. In response to this need, a robust liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was established for the trace‐level quantification of N‐FUR. Chromatographic separation was achieved using a Kinetex C 18 (100 mm × 3.0 mm, 2.6 µm), maintained at 45°C. The mobile phase consisted of water and methanol, in a 50:50 (%, v/v) ratio with 0.1% trifluoroacetic acid, delivered at a flow rate of 0.5 mL/min. Detection was performed using a multiple reaction monitoring approach in electro spray ionization, Negative mode, transitions monitored at m / z 358.0 → 284. The method was rigorously validated in accordance with international regulatory guidelines and demonstrated excellent performance characteristics, confirming its suitability for routine analysis. This validated LC–MS/MS method has been successfully transferred to the quality control unit, enabling routine monitoring of nitrosamine impurities in furosemide formulations.
- 22 December 2025
- Published by Wiley in ChemistrySelect
- Vol. 10 (48)
Microwave‐Assisted Synthesis and Structural Characterization of N‐Nitroso Tofacitinib: Janus Kinase Inhibitor
N‐Nitroso impurities have emerged as a critical concern in pharmaceutical development due to their potential genotoxic and carcinogenic risks, often interrupting clinical programs and affecting the quality of commercial drug products. In this study, a microwave‐assisted green synthetic approach was employed to efficiently generate N‐nitroso Tofacitinib, a key nitrosamine impurity associated with the Janus kinase (JAK) inhibitor Tofacitinib. The method enabled rapid conversion under mild conditions, offering a sustainable strategy for impurity synthesis. An extensive structural elucidation of the synthesized N‐nitroso Tofacitinib impurity (TCB Imp 2) namely 1‐((3R,4R)‐4‐methyl‐3‐(methyl(7H‐pyrrolo[2,3‐d]pyrimidin‐4‐yl)amino)piperidin‐1‐yl)‐3‐(nitroso‐l4‐azanylidyne)propan‐1‐one was carried out using advanced spectroscopic and spectrometric techniques 1D, 2D‐ 1 H NMR, 13 C NMR, 15 N NMR, infrared spectroscopy, and mass spectrometry. A key observation from this study is that nitrosation occurred selectively at the nitrile‐derived side chain rather than at the pyrrolic nitrogen of the core heterocycle, providing new insight into the reactivity and formation pathways of N‐nitrosamine drug substance–related impurities (NDSRIs) in Tofacitinib. Additionally, two other potential N‐nitroso impurities of Tofacitinib were synthesized and fully characterized, expanding the impurity knowledge base. This work enhances mechanistic understanding of nitrosation behavior in Tofacitinib, supports regulatory compliance, and provides high‐quality reference standards for impurity profiling within the generic pharmaceutical industry.
- 22 December 2025
- Published by Wiley in ChemistrySelect
- Vol. 10 (48)
Microwave‐Assisted Synthesis and Structural Characterization of N‐Nitroso Tofacitinib: Janus Kinase Inhibitor
N‐Nitroso impurities have emerged as a critical concern in pharmaceutical development due to their potential genotoxic and carcinogenic risks, often interrupting clinical programs and affecting the quality of commercial drug products. In this study, a microwave‐assisted green synthetic approach was employed to efficiently generate N‐nitroso Tofacitinib, a key nitrosamine impurity associated with the Janus kinase (JAK) inhibitor Tofacitinib. The method enabled rapid conversion under mild conditions, offering a sustainable strategy for impurity synthesis. An extensive structural elucidation of the synthesized N‐nitroso Tofacitinib impurity (TCB Imp 2) namely 1‐((3R,4R)‐4‐methyl‐3‐(methyl(7H‐pyrrolo[2,3‐d]pyrimidin‐4‐yl)amino)piperidin‐1‐yl)‐3‐(nitroso‐l4‐azanylidyne)propan‐1‐one was carried out using advanced spectroscopic and spectrometric techniques 1D, 2D‐ 1 H NMR, 13 C NMR, 15 N NMR, infrared spectroscopy, and mass spectrometry. A key observation from this study is that nitrosation occurred selectively at the nitrile‐derived side chain rather than at the pyrrolic nitrogen of the core heterocycle, providing new insight into the reactivity and formation pathways of N‐nitrosamine drug substance–related impurities (NDSRIs) in Tofacitinib. Additionally, two other potential N‐nitroso impurities of Tofacitinib were synthesized and fully characterized, expanding the impurity knowledge base. This work enhances mechanistic understanding of nitrosation behavior in Tofacitinib, supports regulatory compliance, and provides high‐quality reference standards for impurity profiling within the generic pharmaceutical industry.
- 23 June 2025
- Published by Wiley in Biomedical Chromatography
- Vol. 39 (8) , e70129
Development and Validation of an RP‐HPLC Method for Organic Impurity Profiling in Baclofen Utilizing Robustness Through a Quality‐by‐Design (QbD) Approach: A Comprehensive Forced Degradation Assessment
Strong understandings of science and risk evaluation methodologies are needed to design an analytical method for pharmaceutical quality assessment. This article provides an HPLC method for separating and quantifying baclofen and related impurities. The technique used a Waters Symmetry C18 column, 250 × 4.6 mm, 5 μm in gradient mode. Mobile Phase A was prepared by dissolving 0.0128 M of 1‐octane sulfonic acid sodium salt in water, followed by the addition of 1 mL of orthophosphoric acid and 2 mL of tetrabutylammonium hydroxide to make up to a solution of 1 L. Mobile Phase B was a homogenous mixture of methanol and water in a 900:100 (v/v) ratio. A 0.7‐mL/min flow rate was maintained for 60 min. The sample cooler and column temperatures were kept at 25°C and 32°C with a 10‐μL injection volume. The detecting wavelength was 225 nm. The drug product and material were subjected to acidity, base, oxidation, heat, and photolysis according to International Conference on Harmonization (Q2) criteria. A linear response (R2 > 0.999), accuracy (recoveries 97.1%–102.5%), precision (RS ≤ 5.0%), sensitivity, and specificity were demonstrated by the proposed method. This method ensures reliable analytical performance by cleanly separating compounds. Final method conditions were assessed using a full‐factorial design. Graphical optimization from the design space identified robust technique conditions.
- 23 June 2025
- Published by Wiley in Biomedical Chromatography
- Vol. 39 (8) , e70129
Development and Validation of an RP‐HPLC Method for Organic Impurity Profiling in Baclofen Utilizing Robustness Through a Quality‐by‐Design (QbD) Approach: A Comprehensive Forced Degradation Assessment
Strong understandings of science and risk evaluation methodologies are needed to design an analytical method for pharmaceutical quality assessment. This article provides an HPLC method for separating and quantifying baclofen and related impurities. The technique used a Waters Symmetry C18 column, 250 × 4.6 mm, 5 μm in gradient mode. Mobile Phase A was prepared by dissolving 0.0128 M of 1‐octane sulfonic acid sodium salt in water, followed by the addition of 1 mL of orthophosphoric acid and 2 mL of tetrabutylammonium hydroxide to make up to a solution of 1 L. Mobile Phase B was a homogenous mixture of methanol and water in a 900:100 (v/v) ratio. A 0.7‐mL/min flow rate was maintained for 60 min. The sample cooler and column temperatures were kept at 25°C and 32°C with a 10‐μL injection volume. The detecting wavelength was 225 nm. The drug product and material were subjected to acidity, base, oxidation, heat, and photolysis according to International Conference on Harmonization (Q2) criteria. A linear response (R2 > 0.999), accuracy (recoveries 97.1%–102.5%), precision (RS ≤ 5.0%), sensitivity, and specificity were demonstrated by the proposed method. This method ensures reliable analytical performance by cleanly separating compounds. Final method conditions were assessed using a full‐factorial design. Graphical optimization from the design space identified robust technique conditions.
- Open Access
- 4 September 2024
- Published by Wiley in Biomedical Chromatography
- Vol. 38 (11) , e6001
Development, evaluation of critical method variables and stability assessment using a Box–Behnken design for the determination of organic impurities in a pharmaceutical dosage form of a centrally acting muscle relaxant drug chlorzoxazone
This study validates a stability‐indicating LC method for detecting organic impurities in the chlorzoxazone dosage form. Using a Waters X‐Select R HSS T3 analytical column, mobile phase of it was made by mixing of water, methanol, and glacial acetic acid in the ratio of 700:300:10 (v/v/v). The drug product and drug substance were subjected to the stress conditions such as acid, base, oxidation, heat, and photolysis as per the recommendations of the International Conference on Harmonization (Q2) methodology. The study revealed the susceptibility of 4‐chloro‐2‐aminophenol to alkaline environments, emphasizing peak homogeneity and stability. The method verification, per ICH guidelines and USP, established precision, specificity, linearity, accuracy, and robustness for quality control. The mean impurity recovery ranged from 95.5% to 105.2%, the correlation coefficient ( r ) was greater than 1.000, and the RSD values ( n = 6) ranged from 0.6% to 5.1% across the LOQ–150% ranges. Full‐factorial design tested final method conditions, evaluating multiple parameters concurrently. Graphical optimization within the design space defined strong method requirements, ensuring consistent and reliable outcomes. The study develops and validates chlorzoxazone stability‐indicating methods, employing advanced statistical approaches like design of experiments and factorial design, with resilient conditions established through graphical optimization of the design space.
- 4 September 2024
- Published by Wiley in Biomedical Chromatography
- Vol. 38 (11) , e6001
Open AccessDevelopment, evaluation of critical method variables and stability assessment using a Box–Behnken design for the determination of organic impurities in a pharmaceutical dosage form of a centrally acting muscle relaxant drug chlorzoxazone
This study validates a stability‐indicating LC method for detecting organic impurities in the chlorzoxazone dosage form. Using a Waters X‐Select R HSS T3 analytical column, mobile phase of it was made by mixing of water, methanol, and glacial acetic acid in the ratio of 700:300:10 (v/v/v). The drug product and drug substance were subjected to the stress conditions such as acid, base, oxidation, heat, and photolysis as per the recommendations of the International Conference on Harmonization (Q2) methodology. The study revealed the susceptibility of 4‐chloro‐2‐aminophenol to alkaline environments, emphasizing peak homogeneity and stability. The method verification, per ICH guidelines and USP, established precision, specificity, linearity, accuracy, and robustness for quality control. The mean impurity recovery ranged from 95.5% to 105.2%, the correlation coefficient ( r ) was greater than 1.000, and the RSD values ( n = 6) ranged from 0.6% to 5.1% across the LOQ–150% ranges. Full‐factorial design tested final method conditions, evaluating multiple parameters concurrently. Graphical optimization within the design space defined strong method requirements, ensuring consistent and reliable outcomes. The study develops and validates chlorzoxazone stability‐indicating methods, employing advanced statistical approaches like design of experiments and factorial design, with resilient conditions established through graphical optimization of the design space.
- 1 July 2023
- Published by Wiley in Biomedical Chromatography
- Vol. 37 (9) , e5687
Quality by design tool–evaluated stability‐indicating ultra‐performance liquid chromatography method for the determination of drugs (ritonavir and darunavir) used to treat the human immunodeficiency virus/acquired immunodeficiency syndrome
Ritonavir and darunavir were examined using a ultra‐performance liquid chromatography (UPLC) approach in pharmaceutical dosage forms. The small number of analytical studies that are currently available do not demonstrate the method's stability or nature. The study sought to assess both chemicals using a stability‐indicating approach with a relatively short run time. The HSS C18 (100 × 2.1 mm), 2‐mm column was used for the chromatographic separation, and isocratic elution was used to achieve this. In the mobile phase, methanol and 0.01 M phosphate buffer (pH 4.0) were included in a 60:40 (v/v) ratio. Throughout the analysis, the flow rate was kept at 0.2 mL min−1, and a photodiode array detector set to 266 nm was used to find the major components. The proposed method showed a linear response (r2 > 0.999), and the accuracy was between 98.0% and 102.0%. The precision data showed relative standard deviation ≤1.0%. The UPLC method for quantification of ritonavir and darunavir in pharmaceutical dosage forms using a very short run time of under a minute is the subject of the proposed article. To meet current regulatory criteria, the quality by design idea was used in the method performance verification.
- 1 July 2023
- Published by Wiley in Biomedical Chromatography
- Vol. 37 (9) , e5687
Quality by design tool–evaluated stability‐indicating ultra‐performance liquid chromatography method for the determination of drugs (ritonavir and darunavir) used to treat the human immunodeficiency virus/acquired immunodeficiency syndrome
Ritonavir and darunavir were examined using a ultra‐performance liquid chromatography (UPLC) approach in pharmaceutical dosage forms. The small number of analytical studies that are currently available do not demonstrate the method's stability or nature. The study sought to assess both chemicals using a stability‐indicating approach with a relatively short run time. The HSS C18 (100 × 2.1 mm), 2‐mm column was used for the chromatographic separation, and isocratic elution was used to achieve this. In the mobile phase, methanol and 0.01 M phosphate buffer (pH 4.0) were included in a 60:40 (v/v) ratio. Throughout the analysis, the flow rate was kept at 0.2 mL min−1, and a photodiode array detector set to 266 nm was used to find the major components. The proposed method showed a linear response (r2 > 0.999), and the accuracy was between 98.0% and 102.0%. The precision data showed relative standard deviation ≤1.0%. The UPLC method for quantification of ritonavir and darunavir in pharmaceutical dosage forms using a very short run time of under a minute is the subject of the proposed article. To meet current regulatory criteria, the quality by design idea was used in the method performance verification.
- 11 February 2023
- Published by Wiley in Biomedical Chromatography
- Vol. 37 (4) , e5585
An effective and stability‐indicating method development and optimization utilizing the Box–Behnken design for the simultaneous determination of acetaminophen, caffeine, and aspirin in tablet formulation
Analytical techniques must be sensitive, specific, and accurate to assess the active pharmaceutical ingredients in pharmaceutical dosage forms. The quality‐by‐design (QbD) application has proven to be a practical method for magnifying HPLC operations. This article discusses the successfully developed QbD‐based stability‐indicative LC method for evaluating acetaminophen, caffeine, and aspirin (ASP) in tablet dosage form. To achieve the necessary chromatographic separation, Milli‐Q water, methanol, and glacial acetic acid were employed in the following ratios: 63:35:2 (v/v/v) for mobile phase A and 18:80:2 (v/v/v) for mobile phase B. The flow rate, column temperature, and detecting wavelength were 1.0 ml/min, 40°C, and 275 nm, respectively, and an InertSustain C18 analytical column (150 × 4.6 mm, 3 μm) was used. Linearity was between 10.0 and 150.0 μg/ml for ASP and acetaminophen and between 2.6 and 39.0 μg/ml for caffeine. The accuracy findings were more than 97%, and the correlation coefficient for all three components was found to be greater than 0.999. The validated HPLC method yielded reliable and accurate results. ASP was shown to be vulnerable to both acid and alkaline hydrolysis in the forced degradation study. The described method is capable of separating the degradants produced during stress testing and is regarded as stability indicating. The proposed method can be used for a wider range of other formulations with an appropriate diluent selection and sample preparation procedure optimization.
- 11 February 2023
- Published by Wiley in Biomedical Chromatography
- Vol. 37 (4) , e5585
An effective and stability‐indicating method development and optimization utilizing the Box–Behnken design for the simultaneous determination of acetaminophen, caffeine, and aspirin in tablet formulation
Analytical techniques must be sensitive, specific, and accurate to assess the active pharmaceutical ingredients in pharmaceutical dosage forms. The quality‐by‐design (QbD) application has proven to be a practical method for magnifying HPLC operations. This article discusses the successfully developed QbD‐based stability‐indicative LC method for evaluating acetaminophen, caffeine, and aspirin (ASP) in tablet dosage form. To achieve the necessary chromatographic separation, Milli‐Q water, methanol, and glacial acetic acid were employed in the following ratios: 63:35:2 (v/v/v) for mobile phase A and 18:80:2 (v/v/v) for mobile phase B. The flow rate, column temperature, and detecting wavelength were 1.0 ml/min, 40°C, and 275 nm, respectively, and an InertSustain C18 analytical column (150 × 4.6 mm, 3 μm) was used. Linearity was between 10.0 and 150.0 μg/ml for ASP and acetaminophen and between 2.6 and 39.0 μg/ml for caffeine. The accuracy findings were more than 97%, and the correlation coefficient for all three components was found to be greater than 0.999. The validated HPLC method yielded reliable and accurate results. ASP was shown to be vulnerable to both acid and alkaline hydrolysis in the forced degradation study. The described method is capable of separating the degradants produced during stress testing and is regarded as stability indicating. The proposed method can be used for a wider range of other formulations with an appropriate diluent selection and sample preparation procedure optimization.
- 21 July 2022
- Published by Wiley in Starch - Stärke
- Vol. 74 (9-10)
Chemical Modifications of Turmeric Starch by Oxidation, Phosphorylation, and Succinylation
The goal of this study is to determine how different properties of turmeric starch are changed with oxidation, succinylation, and phosphorylation. These chemical reagents include sodium hypochlorite, octenyl succinic anhydride, sodium trimetaphosphate (STMP), and sodium tripolyphosphate, using the appropriate reagents (STPP). The isolated starch is modified using several chemical reagents, affecting the turmeric starch physicochemical, functional, thermal, and morphological properties. In hydration properties, all modified starches, are observed non‐significant changes, but in the case of swelling power, lower results are observed in oxidized starch, but substantially raised in the remaining both modifications. In all modifications, the amylose content is lower than native starch (31.380.98). Although there is little variation in pH, the modified starches have higher water and oil binding capabilities than native starch. Native starch (26.02 ± 0.04) and oxidized starch (15.46 ± 0.12) result in the highest and lowest percent syneresis respectively, hence modifications lead more stable starches. SEM research reveals particle aggregation and depressions in the structural form of some modified starches. In terms of viscosity metrics, distarch phosphate (6.3898 Pa s) has the highest viscosity while oxidized starch has the lowest viscosity (3.2623 Pa s). The current paper specifies methods for modification of the turmeric starch including oxidation, succinylation, and phosphorylation. The degree of substitution and percentage content of modified starches are calculated and those are carboxyl/carbonyl content in oxidized starch, octenyl succinate content in succinylated starch, and phosphate content in phosphorylated starch. These properties of modified starches would facilitate more applications in the food as well as non‐food industry.
- 21 July 2022
- Published by Wiley in Starch - Stärke
- Vol. 74 (9-10)
Chemical Modifications of Turmeric Starch by Oxidation, Phosphorylation, and Succinylation
The goal of this study is to determine how different properties of turmeric starch are changed with oxidation, succinylation, and phosphorylation. These chemical reagents include sodium hypochlorite, octenyl succinic anhydride, sodium trimetaphosphate (STMP), and sodium tripolyphosphate, using the appropriate reagents (STPP). The isolated starch is modified using several chemical reagents, affecting the turmeric starch physicochemical, functional, thermal, and morphological properties. In hydration properties, all modified starches, are observed non‐significant changes, but in the case of swelling power, lower results are observed in oxidized starch, but substantially raised in the remaining both modifications. In all modifications, the amylose content is lower than native starch (31.380.98). Although there is little variation in pH, the modified starches have higher water and oil binding capabilities than native starch. Native starch (26.02 ± 0.04) and oxidized starch (15.46 ± 0.12) result in the highest and lowest percent syneresis respectively, hence modifications lead more stable starches. SEM research reveals particle aggregation and depressions in the structural form of some modified starches. In terms of viscosity metrics, distarch phosphate (6.3898 Pa s) has the highest viscosity while oxidized starch has the lowest viscosity (3.2623 Pa s). The current paper specifies methods for modification of the turmeric starch including oxidation, succinylation, and phosphorylation. The degree of substitution and percentage content of modified starches are calculated and those are carboxyl/carbonyl content in oxidized starch, octenyl succinate content in succinylated starch, and phosphate content in phosphorylated starch. These properties of modified starches would facilitate more applications in the food as well as non‐food industry.
- 27 May 2022
- Published by A and V Publications in Asian Journal of Pharmaceutical Analysis
- Vol. 12 (2) , 73-77
Development and Validation of Rapid RP-HPLC Method for determination of Deferasirox in Bulk and Tablet Dosage Forms
The reverse phase high performance liquid chromatographic method has been developed for the estimation of Deferasirox in bulk and in tablet dosage form. Further optimized HPLC method was validated as per the current ICH guidelines. The experiment was conducted on a Inertsil ODS-3V C18, 150mm length, 4.6mm ID, and 5µm particle size column using the chromatographic separation was done with 60:40 v/v ratio of Acetonitrile and Buffer (0.05% Orthophosphoric Acid) as the mobile phase at a flow rate of 1.5mL min-1, and detection of component was made at 250nm. The HPLC method was accurate, with linearity ranging from 10.8 to 162µg/mL of Deferasirox, the correlation coeffient >0.999. The method was exposed to a high accuracy of more than 97%. The results disclose the successful applicability of the current process for the estimation of Deferasirox from its drug substance and marketed formulation, which can be consciously inferred to assess the other formulation systems. The developed method was validated in terms of linearity, accuracy, precision, LOD, LOQ, robustness & ruggedness. The proposed method can be helpful in Quality control laboratories for the determination of Deferasirox in the pharmaceutical dosage form.
- 27 May 2022
- Published by A and V Publications in Asian Journal of Pharmaceutical Analysis
- Vol. 12 (2) , 73-77
Development and Validation of Rapid RP-HPLC Method for determination of Deferasirox in Bulk and Tablet Dosage Forms
The reverse phase high performance liquid chromatographic method has been developed for the estimation of Deferasirox in bulk and in tablet dosage form. Further optimized HPLC method was validated as per the current ICH guidelines. The experiment was conducted on a Inertsil ODS-3V C18, 150mm length, 4.6mm ID, and 5µm particle size column using the chromatographic separation was done with 60:40 v/v ratio of Acetonitrile and Buffer (0.05% Orthophosphoric Acid) as the mobile phase at a flow rate of 1.5mL min-1, and detection of component was made at 250nm. The HPLC method was accurate, with linearity ranging from 10.8 to 162µg/mL of Deferasirox, the correlation coeffient >0.999. The method was exposed to a high accuracy of more than 97%. The results disclose the successful applicability of the current process for the estimation of Deferasirox from its drug substance and marketed formulation, which can be consciously inferred to assess the other formulation systems. The developed method was validated in terms of linearity, accuracy, precision, LOD, LOQ, robustness & ruggedness. The proposed method can be helpful in Quality control laboratories for the determination of Deferasirox in the pharmaceutical dosage form.
- 24 October 2021
- Published by Wiley in Biomedical Chromatography
- Vol. 36 (2) , e5269
A simple isocratic LC method for quantification of trace‐level inorganic degradation impurities (ferricyanide, ferrocyanide, nitrite, and nitrate) in sodium nitroprusside injection and robustness by quality using design approach
This study developed and validated a trace‐level quantification inorganic impurities method using reversed‐phase HPLC and performed the robustness check using quality‐by‐design approach by varying the multiple factors simultaneously. This method is economical and simple and exhibits its stability‐indicating nature [for the determination of ferrocyanide ([Fe(CN)₆]4–), ferricyanide ([Fe(CN)6]3−), nitrate (NO3–), and nitrite (NO2–)] in sodium nitroprusside (SNP) drug substance and liquid dosage form. Chromatographic separation was achieved using a USP L43 column (ACE PFP, 150 × 4.6 mm, 3 μm) with a simple isocratic elution. The buffer consists of potassium dihydrogen phosphate (50 mM), tetrabutylammonium hydrogen sulfate (9 mM), and tetrabutylammonium hydroxide (25 mM). The buffer pH was adjusted to 7.2 with tetrabutylammonium hydroxide. The mobile phase was mixed with the buffer and acetonitrile (68:32 v/v). The flow rate was 0.8 mL/min, column temperature was maintained at 30°C, and injection volume was 5.0 μL. The SNP impurities were monitored at 225 nm using a UV detector. Further, the method was validated per the International Council for Harmonisation (ICH) guidelines, and forced degradation studies were carried out under different stress conditions. The detector responses were plotted against concentrations, and correlation was linear (r > 0.999) over the range of 0.8–7.5 μg/mL for ferricyanide; 1.0–37.5 μg/mL for SNP; and 0.2–7.5 μg/mL for ferrocyanide, nitrite, and nitrate. The method repeatability was established for all the impurities with relative standard deviation (%), and the results were found to be less than 2.0.
- 24 October 2021
- Published by Wiley in Biomedical Chromatography
- Vol. 36 (2) , e5269
A simple isocratic LC method for quantification of trace‐level inorganic degradation impurities (ferricyanide, ferrocyanide, nitrite, and nitrate) in sodium nitroprusside injection and robustness by quality using design approach
This study developed and validated a trace‐level quantification inorganic impurities method using reversed‐phase HPLC and performed the robustness check using quality‐by‐design approach by varying the multiple factors simultaneously. This method is economical and simple and exhibits its stability‐indicating nature [for the determination of ferrocyanide ([Fe(CN)₆]4–), ferricyanide ([Fe(CN)6]3−), nitrate (NO3–), and nitrite (NO2–)] in sodium nitroprusside (SNP) drug substance and liquid dosage form. Chromatographic separation was achieved using a USP L43 column (ACE PFP, 150 × 4.6 mm, 3 μm) with a simple isocratic elution. The buffer consists of potassium dihydrogen phosphate (50 mM), tetrabutylammonium hydrogen sulfate (9 mM), and tetrabutylammonium hydroxide (25 mM). The buffer pH was adjusted to 7.2 with tetrabutylammonium hydroxide. The mobile phase was mixed with the buffer and acetonitrile (68:32 v/v). The flow rate was 0.8 mL/min, column temperature was maintained at 30°C, and injection volume was 5.0 μL. The SNP impurities were monitored at 225 nm using a UV detector. Further, the method was validated per the International Council for Harmonisation (ICH) guidelines, and forced degradation studies were carried out under different stress conditions. The detector responses were plotted against concentrations, and correlation was linear (r > 0.999) over the range of 0.8–7.5 μg/mL for ferricyanide; 1.0–37.5 μg/mL for SNP; and 0.2–7.5 μg/mL for ferrocyanide, nitrite, and nitrate. The method repeatability was established for all the impurities with relative standard deviation (%), and the results were found to be less than 2.0.
- 19 February 2021
- Published by Wiley in Biomedical Chromatography
- Vol. 35 (7) , e5096
Development and validation of LC–MS method for the determination of heptaethylene glycol monomethyl ether in benzonatate bulk drugs
A simple and isocratic reverse‐phase liquid chromatography with mass spectrometric method has been developed and validated for the determination of heptaethylene glycol monomethyl ether in benzonatate drug substance. Benzonatate is an oral antitussive drug used to relieve and suppress cough in patients older than 10 years. The presence of residual heptaethylene glycol monomethyl ether in the benzonatate drug substance affects the safety, strength, purity and quality of the drug substance. The subject compound separation was achieved using 0.1% formic acid and acetonitrile (50:50 v/v) at a flow rate of 0.3 ml/min. The Suplex PKB‐100 250 × 4.6 mm, 5 μm LC column was used for a better peak shape. Detection was carried out at an m/z value of 341. The linearity curve showed a correlation of coefficient of >0.999. The precision and intermediate precision (RSD) were 90% for all levels. The developed method was validated as per International Conference on Harmonization guidelines and found to be a novel, specific and sensitive analytical method for determination of components of interest.
- 19 February 2021
- Published by Wiley in Biomedical Chromatography
- Vol. 35 (7) , e5096
Development and validation of LC–MS method for the determination of heptaethylene glycol monomethyl ether in benzonatate bulk drugs
A simple and isocratic reverse‐phase liquid chromatography with mass spectrometric method has been developed and validated for the determination of heptaethylene glycol monomethyl ether in benzonatate drug substance. Benzonatate is an oral antitussive drug used to relieve and suppress cough in patients older than 10 years. The presence of residual heptaethylene glycol monomethyl ether in the benzonatate drug substance affects the safety, strength, purity and quality of the drug substance. The subject compound separation was achieved using 0.1% formic acid and acetonitrile (50:50 v/v) at a flow rate of 0.3 ml/min. The Suplex PKB‐100 250 × 4.6 mm, 5 μm LC column was used for a better peak shape. Detection was carried out at an m/z value of 341. The linearity curve showed a correlation of coefficient of >0.999. The precision and intermediate precision (RSD) were 90% for all levels. The developed method was validated as per International Conference on Harmonization guidelines and found to be a novel, specific and sensitive analytical method for determination of components of interest.