- Open Access
Facial video photoplethysmography for measuring average and instantaneous heart rate: a pilot validation study
Introduction Video photoplethysmography (vPPG) is a contactless optical technique of recording blood pulsations in the skin vasculature using a digital camera, which is increasingly used to measure or estimate various physiological parameters. Here, we evaluate the accuracy of heart rate (HR) measurements performed using facial vPPG technology Shen.AI Vitals and a smartphone camera. Methods We studied 35 healthy volunteers in a sitting position (median age 25 years, 17 females). Video recordings of participants’ faces were obtained using the front camera of a smartphone mounted on a tripod. In parallel, a 1-lead chest electrocardiogram (ECG) was recorded to obtain reference HR values (average value from the entire 60-second measurement and multiple values averaged over 10-second or 4-second periods during the measurement). Results The mean absolute errors were 0.1, 0.2, and 0.4 beats per minute (bpm) for HR averaged over 60-second, 10-second, and 4-second periods, respectively. The errors did not exceed 1 bpm in 100.0%, 99.8%, and 94.5% of cases, respectively. Regardless of the HR averaging time, the correlation between the vPPG-based and reference values was very strong (r > 0.99, P < 0.001). Conclusions In predominantly young, white, sitting subjects, the tested vPPG technology provided highly accurate HR values, both when averaging over 60 seconds as well as in the case of short-term averages over 10 seconds or instantaneous HR values averaged over 4 seconds. The results should be confirmed in a larger study with greater diversity in age, skin tone, and lighting conditions.
Open AccessFacial video photoplethysmography for measuring average and instantaneous heart rate: a pilot validation study
Introduction Video photoplethysmography (vPPG) is a contactless optical technique of recording blood pulsations in the skin vasculature using a digital camera, which is increasingly used to measure or estimate various physiological parameters. Here, we evaluate the accuracy of heart rate (HR) measurements performed using facial vPPG technology Shen.AI Vitals and a smartphone camera. Methods We studied 35 healthy volunteers in a sitting position (median age 25 years, 17 females). Video recordings of participants’ faces were obtained using the front camera of a smartphone mounted on a tripod. In parallel, a 1-lead chest electrocardiogram (ECG) was recorded to obtain reference HR values (average value from the entire 60-second measurement and multiple values averaged over 10-second or 4-second periods during the measurement). Results The mean absolute errors were 0.1, 0.2, and 0.4 beats per minute (bpm) for HR averaged over 60-second, 10-second, and 4-second periods, respectively. The errors did not exceed 1 bpm in 100.0%, 99.8%, and 94.5% of cases, respectively. Regardless of the HR averaging time, the correlation between the vPPG-based and reference values was very strong (r > 0.99, P < 0.001). Conclusions In predominantly young, white, sitting subjects, the tested vPPG technology provided highly accurate HR values, both when averaging over 60 seconds as well as in the case of short-term averages over 10 seconds or instantaneous HR values averaged over 4 seconds. The results should be confirmed in a larger study with greater diversity in age, skin tone, and lighting conditions.
- Open Access
Estimating heart rate variability using facial video photoplethysmography: a pilot validation study
Introduction Video photoplethysmography (vPPG) employs a digital camera to detect blood pulsations in the skin vasculature, which can be used to estimate various physiological parameters. In this study, we investigate the accuracy and precision of two heart rate variability (HRV) indices estimated using a smartphone camera and the facial vPPG technology Shen.AI Vitals. Methods The study group included 35 healthy volunteers (17 females) with median age 25 years (range 20–42 years). The subjects were in a sitting position, keeping their heads relatively still. A smartphone mounted on a tripod was used to acquire 1-min video recordings of participants’ faces. In parallel, a 1-lead chest electrocardiogram (ECG) was recorded to obtain reference values of two analysed time-domain HRV indices: SDNN and lnRMSSD. Results For SDNN, the mean absolute error (MAE) was 3.5 ms (11.0% in relative terms) and the root-mean-square error (RMSE) was 4.5 ms (15.7%). For lnRMSSD, the MAE was 0.24 (7.3%) and RMSE was 0.31 (9.9%). Correlations between the vPPG-based and ECG-based HRV values were strong, with the Pearson correlation coefficient of 0.98 for SDNN and 0.88 for lnRMSSD (P < 0.001 in both cases). Conclusions In a young, white population, the tested vPPG technology estimated HRV indices (SDNN and lnRMSSD) with acceptable accuracy in most subjects, with a slight systematic overestimation, especially for low values. The results should be confirmed in a larger study with greater diversity in age and skin tone.
Open AccessEstimating heart rate variability using facial video photoplethysmography: a pilot validation study
Introduction Video photoplethysmography (vPPG) employs a digital camera to detect blood pulsations in the skin vasculature, which can be used to estimate various physiological parameters. In this study, we investigate the accuracy and precision of two heart rate variability (HRV) indices estimated using a smartphone camera and the facial vPPG technology Shen.AI Vitals. Methods The study group included 35 healthy volunteers (17 females) with median age 25 years (range 20–42 years). The subjects were in a sitting position, keeping their heads relatively still. A smartphone mounted on a tripod was used to acquire 1-min video recordings of participants’ faces. In parallel, a 1-lead chest electrocardiogram (ECG) was recorded to obtain reference values of two analysed time-domain HRV indices: SDNN and lnRMSSD. Results For SDNN, the mean absolute error (MAE) was 3.5 ms (11.0% in relative terms) and the root-mean-square error (RMSE) was 4.5 ms (15.7%). For lnRMSSD, the MAE was 0.24 (7.3%) and RMSE was 0.31 (9.9%). Correlations between the vPPG-based and ECG-based HRV values were strong, with the Pearson correlation coefficient of 0.98 for SDNN and 0.88 for lnRMSSD (P < 0.001 in both cases). Conclusions In a young, white population, the tested vPPG technology estimated HRV indices (SDNN and lnRMSSD) with acceptable accuracy in most subjects, with a slight systematic overestimation, especially for low values. The results should be confirmed in a larger study with greater diversity in age and skin tone.