Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Isaías Chamorro-Cruz has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Analysis of energy consumption and pollutants in additive manufacturing: a comparison of ABS, PLA, and PETG by operational stages

    by Giancarlo Marchetta Cruz, Isaías Chamorro Cruz, Diego Jesus Garcia Cedillo, Francisco De Matías Aguilar, David Franco Martínez, Omar Ismael López Suárez, Raul Rivera Blas, Sergio Guillermo Torres Cedillo

  • Open Access

    Multi-factor optimization of impact energy absorption and failure mechanisms in additively manufactured carbon-nylon composites

    by Isaías Chamorro-Cruz, Rebeca López-Santiago, Dario Lugo-Mata, Gabriella Piccinelli Bocchi, Sergio Guillermo Torres-Cedillo, Jorge Iván Reyes-Guzmán, Mauricio Alberto Ortega-Ruíz, Jacinto Cortés-Pérez, Francisco De Matias-Aguilar, Moises Jimenez-Martinez


  • Development of a Trace-Based Approach for Elastic Characterization of Multi-Material Composite Pipes: Theory and Testing

    by Rebeca López-Santiago, Hilario Hernández-Moreno, Orlando Susarrey-Huerta, Isaías Chamorro-Cruz

  • Open Access

    Design and Development of an Accessible Clip Gauge Extensometer for CMOD Measurement in Fracture Mechanics

    by Isaías Chamorro‐Cruz, Alessandra Gallegos‐Sánchez, Hilario Hernández‐Moreno, Esteban Antunez‐Valencia, Sergio Guillermo Torres‐Cedillo, Gabriella Piccinelli Bocchi, Jorge Iván Reyes‐Guzmán, José Alberto Picaso‐Martínez, Jacinto Cortés‐Pérez

    This work reports on the design, construction, calibration, and validation of a low‐cost, clip‐on extensometer for crack mouth opening displacement (CMOD) measurements in fracture mechanics specimens. The device employs readily available components and integrates a full Wheatstone bridge with instrumentation‐amplifier conditioning to achieve high measurement resolution at minimal cost. A dedicated calibration protocol, combined with the compliance‐based framework specified in the standard, enables direct conversion of bridge output to CMOD. The device's performance was verified on compact tension specimens through a monotonic test, and cross‐validated against a finite element simulation and analytical displacement prediction. The results demonstrated linear‐elastic agreement within experimental uncertainty across a verification window, as well as a reproducible CMOD–time histories suitable for both toughness evaluation and crack‐growth assessments. By providing full documentation of the hardware and manufacture procedures, this study facilitates rapid replication in contexts where commercial instruments may be cost‐prohibitive. Furthermore, it reaffirms that CMOD measurement using clip‐on extensometers remains a robust and essential technique, complementing modern optical methods.

  • Open Access

    Development of a trace-based approach for elastic characterization of multi-material composite pipes: Theory and testing

    by Rebeca López, Hilario Hernández, Orlando Susarrey, Isaías Chamorro

    Design of composite wrap pipes demands accurate experimental determination of the mechanical properties of the materials considered. The emphasis of this article is on the experimental characterization of the overall mechanical properties of the composite pipe through axial tension and internal pressure non-destructive tests. A stiffness matrix trace-based methodology is developed to determine the elastic properties of multi-material composite pipes (PVC liner + GFRP wrap) using only axial loading and internal-pressure tests. The approach identifies axial and hoop Young’s moduli and the axial/hoop Poisson’s ratios at the pipe level, and then infers the in-plane shear modulus from the invariant trace of the reduced stiffness matrix (Tsai modulus), as an alternative way to torsion test. Four nominally identical pipes were manufactured and tested in triplicate under axial tension, axial compression, and internal pressure. Despite identical constituents and processing, measurable variability was observed across pipes, underscoring the need for bulk, pipe-level characterization rather than extrapolation from coupon-level plies. Finite-element simulations using the identified properties reproduced the measured axial and hoop surface strains within the experimental 95% confidence bands for all load cases. The results demonstrate that the proposed, non-destructive, trace-based workflow provides accurate elastic properties for composite pipes while avoiding specialized torsion fixtures and specimen extraction.

  • Open Access

    Design and development of an accessible clip gauge extensometer for CMOD measurement in fracture mechanics

    by Isaías Chamorro-Cruz, Alessandra Gallegos-Sánchez, Hilario Hernández-Moreno, Esteban Antunez-Valencia, Sergio Torres-Cedillo, Gabriella Piccinelli Bocchi, Jorge Iván Reyes-Guzmán, José Alberto Picaso-Martínez, Jacinto Cortés-Pérez

    Not-yet-known not-yet-known not-yet-known unknown This work reports on the design, construction, calibration, and validation of a low-cost, clip-on extensometer for crack mouth opening displacement (CMOD) measurements in fracture mechanics specimens. The device employs readily available components and integrates a full Wheatstone bridge with instrumentation-amplifier conditioning to achieve high measurement resolution at minimal cost. A dedicated calibration protocol, combined with the compliance-based framework specified in the standard, enables direct conversion of bridge output to CMOD. The device’s performance was verified on compact tension specimens through a monotonic test, and cross-validated against a finite element simulation and analytical displacement prediction. The results demonstrated linear-elastic agreement within experimental uncertainty across a verification window, as well as a reproducible CMOD–time histories suitable for both toughness evaluation and crack-growth assessments. By providing full documentation of the hardware and manufacture procedures, this study facilitates rapid replication in contexts where commercial instruments may be cost-prohibitive. Furthermore, it reaffirms that CMOD measurement using clip-on extensometers remains a robust and essential technique, complementing modern optical methods.

  • Open Access

    Effect of the adhesion process and fiber orientation for low-velocity impact response of AA6061-T6 bonded with GFRP

    by Isaías Chamorro-Cruz, Jorge Iván Reyes-Guzmán, Rebeca López-Santiago, Hilario Hernández-Moreno, Sergio Guillermo Torres‐Cedillo, Jacinto Cortés‐Pérez, Moises Jimenez‐Martinez


  • Image Processing Methodology to Quantify Natural Aging in Low Carbon Steels Exposed to Long-Term Service

    by Isaías Chamorro, Diana K. Vite, Manuel A. Beltrán, Diego I. Rivas, Jorge L. González, Héctor J. Dorantes


  • Elliptical one-side composite bonded repair analysis through a differential evolution algorithm

    by Isaías Chamorro-Cruz, Rebeca López-Santiago, Valentin Vázquez-Castillo, Hilario Hernández-Moreno, Manuel Alejandro Beltrán-Zúñiga, Jorge Luis González-Velázquez, Diego Israel Rivas-López

    Purpose: The purpose of this study is to determine the optimal shape of a one-sided elliptical composite material patch of an adhesively bonded repair of cracked metal plates under biaxial stress. Design/methodology/approach: The approach consists on determining the patch topology and adhesive thickness that minimize the stress intensity factor and the bending moment caused by the asymmetry of the repair by applying a differential evolution algorithm with a selection phase using the Deb’s rules. Findings: The results demonstrate that an elliptical patch of major axis length equal to the plate width, and minor axis length equal to the crack length, with a thin adhesive thickness, provides the highest stress intensity factor and bending moment reduction, maximizing the fatigue life of the repair. Research limitations/implications: The results are limited to linear elastic behavior of the cracked plate and a fully rigid bond between the cracked plate and the patch. The effectiveness of the repair was verified by theoretical calculation of the fatigue life, thus experimental validation is still needed. Practical implications: The results of this work can be applied to experimental validations of the effectiveness of the elliptical one-side composite bonded repairs, avoiding and extensive number of experiments, and also, encourage maintainers to explore on this technique that is more economical and easier to apply, in comparison to other repair techniques. By following the patch geometry recommendations proposed herein, it is analytically predicted that the fatigue life may increase by as much as 27 times that of the unpatched plate. Originality/value: Currently, there are no detailed studies that assess one-side patch repair procedures, which require consideration of the bending moment and biaxial stress state, and therefore, the optimal patch geometry and adhesive thickness are unknown.