Abiodun Bayode
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Abiodun Bayode has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Amos Maina
Department of Mechanical Engineering Dedan Kimathi University of Technology, Nyeri 10102, Kenya
1 shared publication - Edwell Tafara Mharakurwa
Department of Electrical and Electronic Engineering, Dedan Kimathi University of Technology, Dedan Kimathi, Nyeri P.O. Box 10143, Kenya
1 shared publication - Fredrick Madaraka Mwema
Dedan Kimathi University of Technology
1 shared publication - Fredrick Mwema
Department of Mechanical Engineering Dedan Kimathi University of Technology, Nyeri 10102, Kenya
1 shared publication - Lungile Nyanga
School of Mechanical Engineering, North-West University, Potchefstroom 98033, South Affrica
1 shared publication - Oluyemi O. Bankole
Department of Mechanical Engineering, Faculty of Engineering, University of Lagos, Akoka 100272, Nigeria
1 shared publication
Latest Publications
- Open Access
- 11 June 2025
- Published by MDPI AG in Prosthesis
- Vol. 7 (3) , 64
Finite Element Analysis and Simulation of 316L Stainless Steel and Titanium Alloy for Orthopedic Hip and Knee Prosthetics
Background: Ferrous metals are used extensively in the manufacturing of plates, pins, Kirschner wires (K-wires), and screws, and in the performance of partial and total joint replacement surgeries for the shoulder, elbow, and wrist joints. The primary surgical procedures commonly performed are hip and knee replacement surgeries. Metals possess a combination of high modulus, yield point, and ductility, rendering them well suited for load-bearing applications, as they can withstand significant loads without experiencing substantial deformations or permanent alterations in their dimensions. Application of metals and alloys is of prime importance in orthopedics as they lead the way to overcoming many issues encountered in implant use. In some instances, pure metals are used, but alloys consisting of two or more elements typically exhibit greater material characteristics, including corrosion resistance as well as toughness. The first item to address when selecting a metallic implant material is its biocompatibility. In this regard, three classes of materials are also commonly known as biomedical metals—316L stainless steel, pure titanium, and titanium alloys. Objective: The aim of this work is to create a model describing the material behavior and then simulate the metals under a load of 2300 N, which is equivalent to plastic loading. Methods: Under ten different case studies, a sub-routine was developed to combine the material characteristics of titanium and 316L stainless steel with the software. Results: The outcomes of the research were then investigated. A femur model was created using ANSYS software, and two materials, stainless steel and titanium, were used. The model was then exposed to a force of 2300 N.
- 11 June 2025
- Published by MDPI AG in Prosthesis
- Vol. 7 (3) , 64
Open AccessFinite Element Analysis and Simulation of 316L Stainless Steel and Titanium Alloy for Orthopedic Hip and Knee Prosthetics
Background: Ferrous metals are used extensively in the manufacturing of plates, pins, Kirschner wires (K-wires), and screws, and in the performance of partial and total joint replacement surgeries for the shoulder, elbow, and wrist joints. The primary surgical procedures commonly performed are hip and knee replacement surgeries. Metals possess a combination of high modulus, yield point, and ductility, rendering them well suited for load-bearing applications, as they can withstand significant loads without experiencing substantial deformations or permanent alterations in their dimensions. Application of metals and alloys is of prime importance in orthopedics as they lead the way to overcoming many issues encountered in implant use. In some instances, pure metals are used, but alloys consisting of two or more elements typically exhibit greater material characteristics, including corrosion resistance as well as toughness. The first item to address when selecting a metallic implant material is its biocompatibility. In this regard, three classes of materials are also commonly known as biomedical metals—316L stainless steel, pure titanium, and titanium alloys. Objective: The aim of this work is to create a model describing the material behavior and then simulate the metals under a load of 2300 N, which is equivalent to plastic loading. Methods: Under ten different case studies, a sub-routine was developed to combine the material characteristics of titanium and 316L stainless steel with the software. Results: The outcomes of the research were then investigated. A femur model was created using ANSYS software, and two materials, stainless steel and titanium, were used. The model was then exposed to a force of 2300 N.
- Open Access
- 20 February 2025
- Published by MDPI AG in Engineering Proceedings
- Vol. 84 (1) , 70
Effects of Screw Speed on Screw Pressure and Temperature: A Case of Non-Newtonian Non-Isothermal Flow
This study uses ANSYS Polyflow to analyze the relationship between speed, temperature, and pressure. A wheat flour’s viscosity, thermal conductivity, and heat capacity were found to be 12,000 cps, 0.375 W/m-K, and 2190 J/kg-K, respectively. The speed was increased from 5 to 100 RPM in five-step increments. The findings of pressure and temperature measurements were examined for statistical significance, as well as the link between change in screw speed and change in pressure and temperature. As the screw speed increased, so did the pressure and temperature, with a maximum of 41 bar and 372 K recorded at 100 RPM. Proper screw speed selection is critical for maintaining optimal pressure and temperature conditions in the extruder, which ensures great product quality and operating efficiency.
- 20 February 2025
- Published by MDPI AG in Engineering Proceedings
- Vol. 84 (1) , 70
Open AccessEffects of Screw Speed on Screw Pressure and Temperature: A Case of Non-Newtonian Non-Isothermal Flow
This study uses ANSYS Polyflow to analyze the relationship between speed, temperature, and pressure. A wheat flour’s viscosity, thermal conductivity, and heat capacity were found to be 12,000 cps, 0.375 W/m-K, and 2190 J/kg-K, respectively. The speed was increased from 5 to 100 RPM in five-step increments. The findings of pressure and temperature measurements were examined for statistical significance, as well as the link between change in screw speed and change in pressure and temperature. As the screw speed increased, so did the pressure and temperature, with a maximum of 41 bar and 372 K recorded at 100 RPM. Proper screw speed selection is critical for maintaining optimal pressure and temperature conditions in the extruder, which ensures great product quality and operating efficiency.
- Open Access
- 20 February 2025
- Published by MDPI AG in Engineering Proceedings
- Vol. 84 (1) , 69
A Numerical Study on the Effect of Gate Position to the Structural Integrity of Plastic Injection-Molded Biomedical Implants
Optimizing the injection molding process for making biomedical implants is essential to avoid defects that impact patient safety and implant performance. This study examines how different gate positions affect defect rates in injection-molded polyether ether ketone (PEEK) pedicle screws, using numerical modeling to analyze melt flow, cavity pressure, sink mark depth, warpage, and Von Mises stress across four gate configurations. The findings show that gate position significantly influences structural integrity, with strategically placed gates reducing defects by promoting uniform flow. Gate configuration 2 was optimal, yielding minimal sink depth, low warpage, and low stress, while configuration 4 was the least effective as it was associated with higher values of defect rates. Carefully selecting gate positions can enhance the quality and reliability of biomedical implants.
- 20 February 2025
- Published by MDPI AG in Engineering Proceedings
- Vol. 84 (1) , 69
Open AccessA Numerical Study on the Effect of Gate Position to the Structural Integrity of Plastic Injection-Molded Biomedical Implants
Optimizing the injection molding process for making biomedical implants is essential to avoid defects that impact patient safety and implant performance. This study examines how different gate positions affect defect rates in injection-molded polyether ether ketone (PEEK) pedicle screws, using numerical modeling to analyze melt flow, cavity pressure, sink mark depth, warpage, and Von Mises stress across four gate configurations. The findings show that gate position significantly influences structural integrity, with strategically placed gates reducing defects by promoting uniform flow. Gate configuration 2 was optimal, yielding minimal sink depth, low warpage, and low stress, while configuration 4 was the least effective as it was associated with higher values of defect rates. Carefully selecting gate positions can enhance the quality and reliability of biomedical implants.