Encheng Zhu
Encheng Zhu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Jianlin Xia
School of Integrated Circuits, Southeast University, Nanjing 210096, China
2 shared publications - Weifeng Sun
Southeast University
2 shared publications - Yongjia Li
School of Integrated Circuits, Southeast University, Nanjing, China
2 shared publications - Shen Xu
National ASIC System Engineering Research Center, Southeast University, Nanjing, Jiangsu, China
1 shared publication - Yang Yang
School of Integrated Circuits, Southeast University, Nanjing 210096, China
1 shared publication - Yi Liu
School of Integrated Circuits, Southeast University, Nanjing 210096, China
1 shared publication
Latest Publications
- Open Access
- 14 September 2026
- Published by MDPI AG in Electronics
- Vol. 15 (18) , 4155
An Incremental Zoom ADC Readout IC and FPGA-Based Digital Calibration System for High-Precision Capacitive Pressure Sensors
This work presents an incremental zoom analog-to-digital converter (ADC) readout integrated circuit (IC) and field-programmable gate array (FPGA)-based digital calibration system for high-precision capacitive micro electro-mechanical system (MEMS) pressure sensors, aimed at enhancing pressure readout resolution, pressure measurement accuracy, and long-term output stability. In the readout IC, the zoom ADC employs coarse-fine quantization, achieving high readout accuracy while relaxing requirements on integrator output swing and front-end linearity. On the digital side, a sparrow-search-algorithm-optimized Gaussian process regression (SSA-GPR) model constructs a nonlinear pressure–temperature mapping with limited calibration samples, while a segmented aging-compensation scheme based on dual-channel periodic self-test dynamically corrects aging-induced offset and sensitivity drifts. Together, these three techniques form a complete signal-conditioning chain addressing weak capacitance variation readout, pressure–temperature coupling, and long-term drift. Measured results show 0.11 PaRMS output root mean square (RMS) noise under a 205.2 ms conversion time, 37.44 Pa mean absolute error over −40 °C to 85 °C and 30 kPa to 120 kPa, and ±30 Pa residual error after 85 °C/1000 h aging, confirming the effectiveness of the proposed readout IC and digital calibration system.
- 14 September 2026
- Published by MDPI AG in Electronics
- Vol. 15 (18) , 4155
Open AccessAn Incremental Zoom ADC Readout IC and FPGA-Based Digital Calibration System for High-Precision Capacitive Pressure Sensors
This work presents an incremental zoom analog-to-digital converter (ADC) readout integrated circuit (IC) and field-programmable gate array (FPGA)-based digital calibration system for high-precision capacitive micro electro-mechanical system (MEMS) pressure sensors, aimed at enhancing pressure readout resolution, pressure measurement accuracy, and long-term output stability. In the readout IC, the zoom ADC employs coarse-fine quantization, achieving high readout accuracy while relaxing requirements on integrator output swing and front-end linearity. On the digital side, a sparrow-search-algorithm-optimized Gaussian process regression (SSA-GPR) model constructs a nonlinear pressure–temperature mapping with limited calibration samples, while a segmented aging-compensation scheme based on dual-channel periodic self-test dynamically corrects aging-induced offset and sensitivity drifts. Together, these three techniques form a complete signal-conditioning chain addressing weak capacitance variation readout, pressure–temperature coupling, and long-term drift. Measured results show 0.11 PaRMS output root mean square (RMS) noise under a 205.2 ms conversion time, 37.44 Pa mean absolute error over −40 °C to 85 °C and 30 kPa to 120 kPa, and ±30 Pa residual error after 85 °C/1000 h aging, confirming the effectiveness of the proposed readout IC and digital calibration system.
- Open Access
- 25 February 2025
- Published by MDPI AG in Electronics
- Vol. 14 (5) , 904
Design and Control of the Resonant Auxiliary Circuit for Voltage Regulator Module (VRM) with Fast Load Step Transient
This paper proposes a transient energy auxiliary supply circuit architecture based on resonant switched-capacitor principles, aimed at optimizing the system’s transient response to meet the growing power supply demands. This paper first introduces the relevant principles of resonant switched-capacitor converters. Based on this, a transient energy path topology based on resonant principles is designed to achieve bidirectional, fast, and low electromagnetic interference energy transmission. Corresponding system coordination control strategies and high-precision switch control based on delay lines are proposed for the designed circuit topology. A circuit model is built in SIMPLIS (V8.20a) software for system simulation, and a prototype is built based on FPGA to verify circuit functionality and performance. Experimental results demonstrate that the resonant energy auxiliary circuit can operate in conjunction with a six-phase Buck circuit prototype. Under test conditions of a 500 kHz operating frequency, 6.5 V input voltage, and 0.75 V output voltage, the overshoot voltage is reduced by more than 17% across the entire operating range. When the load steps from 200 A to 20 A, the overshoot voltage is reduced to only 85 mV, a decrease of 27.97%, while the recovery time is 28.8 µs, a reduction of 37.66%. These results confirm that the auxiliary circuit can significantly improve the system’s transient response under large load steps, meeting the design requirements.
- 25 February 2025
- Published by MDPI AG in Electronics
- Vol. 14 (5) , 904
Open AccessDesign and Control of the Resonant Auxiliary Circuit for Voltage Regulator Module (VRM) with Fast Load Step Transient
This paper proposes a transient energy auxiliary supply circuit architecture based on resonant switched-capacitor principles, aimed at optimizing the system’s transient response to meet the growing power supply demands. This paper first introduces the relevant principles of resonant switched-capacitor converters. Based on this, a transient energy path topology based on resonant principles is designed to achieve bidirectional, fast, and low electromagnetic interference energy transmission. Corresponding system coordination control strategies and high-precision switch control based on delay lines are proposed for the designed circuit topology. A circuit model is built in SIMPLIS (V8.20a) software for system simulation, and a prototype is built based on FPGA to verify circuit functionality and performance. Experimental results demonstrate that the resonant energy auxiliary circuit can operate in conjunction with a six-phase Buck circuit prototype. Under test conditions of a 500 kHz operating frequency, 6.5 V input voltage, and 0.75 V output voltage, the overshoot voltage is reduced by more than 17% across the entire operating range. When the load steps from 200 A to 20 A, the overshoot voltage is reduced to only 85 mV, a decrease of 27.97%, while the recovery time is 28.8 µs, a reduction of 37.66%. These results confirm that the auxiliary circuit can significantly improve the system’s transient response under large load steps, meeting the design requirements.