RCRegis Chayramy

Regis Chayramy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Regis Chayramy has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of Sampler Characteristics in Differential Sampling Adopting a Programmable Josephson Voltage Standard

    by Mun-Seog Kim, Hehree Cho, Régis Chayramy, Stéphane Solve

    We investigated the impact of measurement circuit configuration, sampler gain error, sampling trigger delay setting, and the built-in filter of the sampler on the accuracy of quantumbased differential sampling. In addition, we evaluated through numerical simulations how the filter function for NI PXI-5922, which changes with sampling rate, is reflected in differential sampling. We found that the filter introduces ripples throughout the differential signal, resulting in a measurement error proportional to frequency. At 3.125 kHz, the maximum difference among the RMS amplitude values obtained with different sampling rates was approximately 2 μV/V. Finally, we performed differential sampling on 1 V AC waveforms using NI PXI-5922 and Fluke 8588A, with bandwidths set to 3 MHz or higher. We found that the RMS amplitude values obtained by the two different samplers agreed within ±52 nV in the frequency range below 1.25 kHz.


  • Metrology of Zener-based secondary voltage standards

    by R Chayramy, S Yang, O Power, S Solve

    The BIPM (Bureau International des Poids et Mesures) has been carefully maintaining Zener diode secondary voltage standards (ZVS) for about 30 years, which are used in an ongoing international bilateral comparison program with national metrology institutes. The output voltages of the standards are corrected for their sensitivity to parameters such as their internal temperature (relative to the thermistor resistance of the Zener’s oven) and atmospheric pressure. In 2016 and 2017, these sensitivity coefficients were redetermined. The corresponding corrections vary between −7 parts in 10 7 kΩ −1 to +6 parts in 10 7 kΩ −1 , and from +8 parts in 10 10 hPa −1 to +2 parts in 10 9 hPa −1 , respectively. In the worst case, the combination of the effect of temperature and pressure are comparable to the 1 f −1 noise floor of these standards (considered to be 1 part in 10 8 at the BIPM). Most of the sensitivity coefficients have not changed since their previous determination in 1998–2002 which seems to indicate that they are intrinsic characteristics of the ZVS, which are dependent upon the properties of the physical support of the Zener element itself (pressure sensitivity) and the intrinsic behaviour of the internal thermistor (temperature sensitivity). As a follow-up to the determination of the new sensitivity coefficients, the reproducibility of the ZVS calibration was also investigated, using three different and independent measurement setups, each built around a different and independent Josephson voltage standard. The metrological performance of the three primary setups were demonstrated to have an agreement of between 2 × 10 −10 and 1 × 10 −11 when compared directly. The comparison results of the calibration of the BIPM ZVS showed that most artefacts reach an agreement of a few parts in 10 9 while a very few can exhibit a considerable systematic error comparable to the 1 f −1 noise, which we suspect is due to a nonzero current from the measuring system flowing through the input impedance of the standard.


  • Bilateral comparison of 1 V and 10 V standards between the NMISA (South Africa) and the BIPM April to June 2017 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    by S Solve, R Chayramy, A M Matlejoane, L Magagula, M Stock

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1.018 V and 10 V voltage reference standards of the BIPM and the National Metrology Institute of South Africa, NMISA (South Africa), was carried out from April to June 2017. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_A (ZA) and BIPM_B (ZB), were transported by freight to NMISA and back to BIPM. In order to keep the Zeners powered during their transportation phase, a voltage stabilizer developed by BIPM was connected in parallel to the internal battery. It consists of a set of two batteries, electrically protected from surcharge-discharge, easy to recharge and is designed to power two transfer standards for ten consecutive days. At NMISA, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at NMISA, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by NMISA, at the level of 1.018 V and 10 V, at NMISA, U NMISA , and those assigned by the BIPM, at the BIPM, U BIPM , at the reference dates of the 19 th and 18 th of May 2017, respectively. U NMISA − U BIPM = + 0.07 μV; u c = 0.02 μV, at 1.018 V U NMISA − U BIPM = + 0.001 μV; u c = 0.34 μV, at 10 V where u c is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NMISA, based on K J-90 , and the uncertainty related to the comparison. Main text To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/ . The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).


  • Temperature sensitivity coefficients of the BIPM secondary voltage standards

    by Stephane Solve, Regis Chayramy

    The BIPM bilateral comparison program using secondary voltage standards as travelling references, identified as BIPM.EM-K11 in the CIPM-MRA framework, has been on-going for more than 20 years. As this comparison is not very demanding on workload and is very easy to realise, NMIs still participate at a rate of 2 to 3 participants a year for different objectives: to validate a change of technical staff or a technical improvement in the labs, but also, most importantly, for the preparation of an on-site comparison of the primary realization of the volt, using Josephson voltage standards. The output voltages of the BIPM travelling Zener standards are corrected for their dependence on temperature changes in the enclosure of the Zener voltage reference. No re-evaluation of the sensitivity coefficients has been performed since the original measurements between 1998 and 2002. We have reasons to believe that these coefficients have changed over the past 10 years and we need to confirm this assumption. A new measurement chain has been set up to perform this study, using the same methodology operated for the initial determination of the coefficients.