Effect of Sampler Characteristics in Differential Sampling Adopting a Programmable Josephson Voltage Standard
Open Access
- 24 February 2025
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-7
Abstract
We investigated the impact of measurement circuit configuration, sampler gain error, sampling trigger delay setting, and the built-in filter of the sampler on the accuracy of quantumbased differential sampling. In addition, we evaluated through numerical simulations how the filter function for NI PXI-5922, which changes with sampling rate, is reflected in differential sampling. We found that the filter introduces ripples throughout the differential signal, resulting in a measurement error proportional to frequency. At 3.125 kHz, the maximum difference among the RMS amplitude values obtained with different sampling rates was approximately 2 μV/V. Finally, we performed differential sampling on 1 V AC waveforms using NI PXI-5922 and Fluke 8588A, with bandwidths set to 3 MHz or higher. We found that the RMS amplitude values obtained by the two different samplers agreed within ±52 nV in the frequency range below 1.25 kHz.Keywords
Funding Information
- Research on Measurement Standards for the Redefinition of SI Units
- Korea Research Institute of Standards and Science (KRISS-2024-GP2024-0001)
This publication has 24 references indexed in Scilit:
- Differential sampling of AC waveforms based on a programmable Josephson voltage standard using a high-precision samplerMetrologia, 2022
- An AC quantum voltmeter for frequencies up to 100 kHz using sub-samplingMetrologia, 2021
- Measurement configurations for differential sampling of AC waveforms based on a programmable Josephson voltage standard: effects of sampler bandwidth on the measurementsMetrologia, 2020
- Characterization of a precision modular sinewave generatorMeasurement Science and Technology, 2020
- Design and implementation of differential AC voltage sampling system based on PJVSMeasurement, 2018
- Effect of Input Bandwidth of a Sampler on Differential Sampling Based on a Programmable Josephson Voltage Standard2018
- An ac quantum voltmeter based on a 10 V programmable Josephson arrayMetrologia, 2013
- Analog-to-digital conversion for low-frequency waveforms based on the Josephson voltage standardMeasurement Science and Technology, 2010
- Precision sampling measurements using ac programmable Josephson voltage standardsReview of Scientific Instruments, 2008
- Numerical recipes: the art of scientific computingAnalytica Chimica Acta, 1987