Lingyun Gu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lingyun Gu has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Changkai Shi
China Electric Power Research Institute, Beijing, China
1 shared publication- Ge Zheng
China Electric Power Research Institute
1 shared publication Hongfang Han
1 shared publicationHuang Zheng
1 shared publication- Huiyang Wang
Key Laboratory of Child Development and Learning Science of Ministry of Education, School of Biological Science and Medical Engineering, Southeast University, Nanjing, China
1 shared publication - Jie Chen
China Electric Power Research Institute
1 shared publication
Latest Publications
- 15 June 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 125
Multimodal integration of fNIRS and acoustic features for depressive symptom classification
- 15 June 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 125
Multimodal integration of fNIRS and acoustic features for depressive symptom classification
- 28 February 2025
- Published by Springer Nature
- p. 450-460
Review of Risk Assessment for Distribution Systems
- 28 February 2025
- Published by Springer Nature
- p. 450-460
Review of Risk Assessment for Distribution Systems
- Open Access
- 1 July 2019
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 300 (4) , 042117
Research on Test of Key Parameters of On-Load Tap-Changer in Transformer
There are two main testing methods for the key parameters of the transformer on-load tap changer. One is the DC test method and the other is the AC test method. Based on the AC test method for on-load tap changer key parameters, a new test scheme was proposed. The on-load tap changer switching operation of the transformer can be simulated by establishing a model. The waveforms of the transitional AC current and the testing AC voltage are stored and preprocessed. Then the transitional AC current is equivalent to DC components through the Park transformation. By using the off-line identification algorithm, the transient stage of the transformer on-load tap changers can be determined and the transition resistance value can be accurately calculated.
- 1 July 2019
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 300 (4) , 042117
Open AccessResearch on Test of Key Parameters of On-Load Tap-Changer in Transformer
There are two main testing methods for the key parameters of the transformer on-load tap changer. One is the DC test method and the other is the AC test method. Based on the AC test method for on-load tap changer key parameters, a new test scheme was proposed. The on-load tap changer switching operation of the transformer can be simulated by establishing a model. The waveforms of the transitional AC current and the testing AC voltage are stored and preprocessed. Then the transitional AC current is equivalent to DC components through the Park transformation. By using the off-line identification algorithm, the transient stage of the transformer on-load tap changers can be determined and the transition resistance value can be accurately calculated.