Sebastien Dine
Research Subjects
Sebastien Dine has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Laurent Marot
University of Basel
3 shared publications - Artem M. Dmitriev
Department of Physics, University of Basel, Klingelbergstrasse 82, CH-4056 Basel, Switzerland
2 shared publications - Ernst Meyer
Department of Physics University of Basel Basel Switzerland
2 shared publications - Jérôme Moritz
Université de Lorraine, CNRS, IJL 2 , F-54000 Nancy
2 shared publications - Paul Hiret
Universität Basel
2 shared publications R. Steiner
Department of Physics, University of Basel 1 , Klingelbergstrasse 82, CH-4056 Basel
2 shared publications
Latest Publications
- Open Access
- 21 January 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (2) , 026042
Influence of 3 T magnetic field on RF plasma self-bias and erosion pattern for the ITER wide angle viewing system
The ITER Wide Angle Viewing System (WAVS) relies on in-vessel metallic first mirrors (FM) to transport optical signals from the plasma to out-of-vessel diagnostics. Under the conditions of ITER, energetic plasma particles induce sputtering of plasma-facing components, and the resulting sputtered material can re-deposit on these mirrors, resulting in reflectivity degradation. In-situ plasma removal using radio-frequency (RF) capacitively coupled plasma discharges is one of the proposed methods to mitigate this issue. Experiments were conducted in a 3 T homogeneous magnetic field using a medical magnetic resonance imaging (MRI) system at the University Hospital of Basel. The WAVS First Mirror Unit consists of two mirror electrodes (M1 and M2), one or both of which can be powered with RF, while the remaining surfaces act as grounded areas. Systematic measurements of the self-bias voltage were performed for varying discharge conditions, including gas species (argon and helium), pressure (0.1–10 Pa) and mirror capacitance, as well as the angle θ between the mirror surface and magnetic field. The results revealed a strong dependence of the self-bias on the grounded-to-powered area ratio A g / A p , which is affected by the magnetic confinement. Erosion and deposition patterns were examined in cases where one or both mirrors were powered. Erosion occurred primarily where a powered mirror faces a grounded surface, whereas overlapping discharges in the dual-powered case resulted in low ion kinetic energy and preferential net deposition at the overlapping area. These observations were supported by one-dimensional simulations of plasma potential evolution under representative conditions. These results provide critical insight into RF plasma behaviour in fully magnetised, geometrically asymmetric discharges and support the development of robust in-situ cleaning strategies for ITER optical diagnostics.
- 21 January 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (2) , 026042
Open AccessInfluence of 3 T magnetic field on RF plasma self-bias and erosion pattern for the ITER wide angle viewing system
The ITER Wide Angle Viewing System (WAVS) relies on in-vessel metallic first mirrors (FM) to transport optical signals from the plasma to out-of-vessel diagnostics. Under the conditions of ITER, energetic plasma particles induce sputtering of plasma-facing components, and the resulting sputtered material can re-deposit on these mirrors, resulting in reflectivity degradation. In-situ plasma removal using radio-frequency (RF) capacitively coupled plasma discharges is one of the proposed methods to mitigate this issue. Experiments were conducted in a 3 T homogeneous magnetic field using a medical magnetic resonance imaging (MRI) system at the University Hospital of Basel. The WAVS First Mirror Unit consists of two mirror electrodes (M1 and M2), one or both of which can be powered with RF, while the remaining surfaces act as grounded areas. Systematic measurements of the self-bias voltage were performed for varying discharge conditions, including gas species (argon and helium), pressure (0.1–10 Pa) and mirror capacitance, as well as the angle θ between the mirror surface and magnetic field. The results revealed a strong dependence of the self-bias on the grounded-to-powered area ratio A g / A p , which is affected by the magnetic confinement. Erosion and deposition patterns were examined in cases where one or both mirrors were powered. Erosion occurred primarily where a powered mirror faces a grounded surface, whereas overlapping discharges in the dual-powered case resulted in low ion kinetic energy and preferential net deposition at the overlapping area. These observations were supported by one-dimensional simulations of plasma potential evolution under representative conditions. These results provide critical insight into RF plasma behaviour in fully magnetised, geometrically asymmetric discharges and support the development of robust in-situ cleaning strategies for ITER optical diagnostics.
- Open Access
- 1 September 2025
- Published by AIP Publishing in Physics of Plasmas
- Vol. 32 (9)
Measurements of RF plasma sheath thickness in magnetic field up to 500 mT using a floating spiral probe
The thickness of the radio frequency (RF) plasma sheath developing in front of a capacitively coupled electrode has been measured using a floating probe. The probe presented in this contribution is based on the floating loop probe first developed by Godyak et al. To study the sheath potential in a smaller vacuum vessel, the probe has been designed in a spiral shape to maximize its sheath capacitance while occupying a reduced volume. During the time oscillation of the sheath, the probe's position influences the time variation of the probe's floating potential, unveiling the sheath thickness. Due to the strong direct current (DC) bias developing on the electrode and the significant RF frequency compared to the plasma ion frequency, the ions responded to the time-averaged sheath electric field. The measured time-average sheath thickness was comparable to the existing DC models with and without a magnetic field for pressures ranging from 2 to 10 Pa. Within this range of pressure, the sheath thickness decreased from 13 to 5 mm, due to the density increase. In a magnetic field, the sheath potential drop decreased and the plasma density increased, leading to a reduction of the sheath size. With the spiral floating probe, no magnetic pre-sheaths were observed up to 500 mT as predicted by Ahedo criterion.
- 1 September 2025
- Published by AIP Publishing in Physics of Plasmas
- Vol. 32 (9)
Open AccessMeasurements of RF plasma sheath thickness in magnetic field up to 500 mT using a floating spiral probe
The thickness of the radio frequency (RF) plasma sheath developing in front of a capacitively coupled electrode has been measured using a floating probe. The probe presented in this contribution is based on the floating loop probe first developed by Godyak et al. To study the sheath potential in a smaller vacuum vessel, the probe has been designed in a spiral shape to maximize its sheath capacitance while occupying a reduced volume. During the time oscillation of the sheath, the probe's position influences the time variation of the probe's floating potential, unveiling the sheath thickness. Due to the strong direct current (DC) bias developing on the electrode and the significant RF frequency compared to the plasma ion frequency, the ions responded to the time-averaged sheath electric field. The measured time-average sheath thickness was comparable to the existing DC models with and without a magnetic field for pressures ranging from 2 to 10 Pa. Within this range of pressure, the sheath thickness decreased from 13 to 5 mm, due to the density increase. In a magnetic field, the sheath potential drop decreased and the plasma density increased, leading to a reduction of the sheath size. With the spiral floating probe, no magnetic pre-sheaths were observed up to 500 mT as predicted by Ahedo criterion.
- Open Access
- 1 March 2025
- Published by Elsevier in Fusion Engineering and Design
- Vol. 214
Mirror dual cleaning of ITER equatorial diagnostic Wide Angle Viewing System
- 1 March 2025
- Published by Elsevier in Fusion Engineering and Design
- Vol. 214
Open AccessMirror dual cleaning of ITER equatorial diagnostic Wide Angle Viewing System
- Open Access
- 11 February 2019
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 37 (2) , 021303
Experimental demonstration of multifrequency impedance matching for tailored voltage waveform plasmas
Driving radiofrequency capacitively coupled plasmas by multiharmonic tailored voltage waveforms (TVWs) has been shown to allow considerable control over various plasma properties for surface processing applications. However, industrial adoption of this technology would benefit from more efficient solutions to the challenge of impedance matching the radiofrequency power source to the load simultaneously at multiple harmonic frequencies. The authors report on the design and demonstration of a simple, practical multifrequency matchbox (MFMB) based on a network of LC resonant circuits. The performance of the matchbox was quantified in terms of a range of matchable impedances (when matching a single frequency at a time), as well as for the independence of each match to changes at adjacent harmonics. The effectiveness of the MFMB was demonstrated experimentally on an Ar plasma excited by a three-frequency TVW with a fundamental frequency of 13.56 MHz. Under the plasma conditions studied, the power coupling efficiency (at the generator output) was increased from less than 40% (without impedance matching) to between 80% and 99% for the different exciting frequencies.
- 11 February 2019
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 37 (2) , 021303
Open AccessExperimental demonstration of multifrequency impedance matching for tailored voltage waveform plasmas
Driving radiofrequency capacitively coupled plasmas by multiharmonic tailored voltage waveforms (TVWs) has been shown to allow considerable control over various plasma properties for surface processing applications. However, industrial adoption of this technology would benefit from more efficient solutions to the challenge of impedance matching the radiofrequency power source to the load simultaneously at multiple harmonic frequencies. The authors report on the design and demonstration of a simple, practical multifrequency matchbox (MFMB) based on a network of LC resonant circuits. The performance of the matchbox was quantified in terms of a range of matchable impedances (when matching a single frequency at a time), as well as for the independence of each match to changes at adjacent harmonics. The effectiveness of the MFMB was demonstrated experimentally on an Ar plasma excited by a three-frequency TVW with a fundamental frequency of 13.56 MHz. Under the plasma conditions studied, the power coupling efficiency (at the generator output) was increased from less than 40% (without impedance matching) to between 80% and 99% for the different exciting frequencies.