Han Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Han Wu has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Shaobo Qu
Huazhong University of Science and Technology
4 shared publications - Yanzheng Bai
Huazhong University of Science and Technology
4 shared publications - Zebing Zhou
Huazhong University of Science and Technology
4 shared publications - Cheng Ma
Huazhong University of Science and Technology
3 shared publications - Hui Chen
National Gravitation Laboratory, the MOE Key Laboratory of Fundamental Physical Quantities Measurement, and the School of Physics, Huazhong University of Science and Technology, Wuhan, China
3 shared publications - Ming Hu
Huazhong University of Science and Technology
3 shared publications
Latest Publications
- 30 October 2025
- Published by Elsevier in Measurement
- Vol. 258
Dynamic range extension and noise evaluation of a high-precision temperature sensor with adaptive switching measuring points
- 30 October 2025
- Published by Elsevier in Measurement
- Vol. 258
Dynamic range extension and noise evaluation of a high-precision temperature sensor with adaptive switching measuring points
- 24 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
High-Precision Inertial Sensor Calibration Using Electromagnetic Excitation on an Active Vibration Isolating Bench
High-precision inertial sensors are key instruments in many space science missions, and need to be verified on the ground to ensure that they operate reliably in orbit with the designed accuracy. However, for inertial sensors with accuracy of 10-10 m/s2 or even higher, traditional calibration method put forward higher requirements for facilities and environment, and the test precision level is usually limited by seismic noise. In this study, an electromagnetic excitation calibration method of high-precision inertial sensors is proposed and experimentally verified. The active controlled four-wire pendulum provides a low-noise ground test bench. The driving force required for calibration is generated by the non-contact electromagnetic actuator, which drives the bench to move along the calibration direction. A high-precision electrostatic accelerometer and two commercial seismometers are used for experimental testing and comparison. The experimental results show that the proposed method can realize the sensitivity coefficient calibration, amplitude-frequency response calibration, and resolution calibration of the highvoltage levitation electrostatic accelerometer. The uncertainty of the sensitivity calibration is evaluated to be 0.07%, and the resolution is evaluated to be 2.8×10-10 m/s2 at 0.5 Hz. This work provides a new high-precision dynamic performance test facility for high precision inertial sensors.
- 24 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
High-Precision Inertial Sensor Calibration Using Electromagnetic Excitation on an Active Vibration Isolating Bench
High-precision inertial sensors are key instruments in many space science missions, and need to be verified on the ground to ensure that they operate reliably in orbit with the designed accuracy. However, for inertial sensors with accuracy of 10-10 m/s2 or even higher, traditional calibration method put forward higher requirements for facilities and environment, and the test precision level is usually limited by seismic noise. In this study, an electromagnetic excitation calibration method of high-precision inertial sensors is proposed and experimentally verified. The active controlled four-wire pendulum provides a low-noise ground test bench. The driving force required for calibration is generated by the non-contact electromagnetic actuator, which drives the bench to move along the calibration direction. A high-precision electrostatic accelerometer and two commercial seismometers are used for experimental testing and comparison. The experimental results show that the proposed method can realize the sensitivity coefficient calibration, amplitude-frequency response calibration, and resolution calibration of the highvoltage levitation electrostatic accelerometer. The uncertainty of the sensitivity calibration is evaluated to be 0.07%, and the resolution is evaluated to be 2.8×10-10 m/s2 at 0.5 Hz. This work provides a new high-precision dynamic performance test facility for high precision inertial sensors.
- 7 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (8) , 13073-13083
Performance Investigation of a High-Precision Charge-Discharge Differential Capacitance Sensor
Capacitive sensing circuit is one of the key technologies in the development of a series of deep space exploration instruments, such as inertial sensors in space gravitational wave detection mission and seismometers in planetary / lunar exploration programs. Space exploration missions require high precision, low-power and high-reliable capacitive sensing circuits. Although the traditional bridge-based capacitive detection circuits widely used currently behave high accuracy, they have a relatively complex structure and higher power consumption. In this paper, a charge-discharge differential capacitive sensing circuit based on high stability square-wave generator, ring-diode switch and low noise trans-impedance amplifier is proposed and investigated systematically. The system noise model is presented based on detailed analysis and measurement of the main noise sources. Low noise design optimization scheme is proposed based on the noise model. A prototype circuit is developed and tested. The sensitivities with several different excitation frequencies are calibrated. The measured noise is compared to the theoretical model and demonstrates a good consistency. The experimental results show that the noise equivalent capacitance resolution of this circuit reaches 0.24 aF/Hz1/2 at 0.1 Hz and 0.028 aF/Hz1/2 at 100 Hz. Benefitting from its simple structure and high measurement accuracy, it is highly suitable for space exploration instruments and other applications.
- 7 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (8) , 13073-13083
Performance Investigation of a High-Precision Charge-Discharge Differential Capacitance Sensor
Capacitive sensing circuit is one of the key technologies in the development of a series of deep space exploration instruments, such as inertial sensors in space gravitational wave detection mission and seismometers in planetary / lunar exploration programs. Space exploration missions require high precision, low-power and high-reliable capacitive sensing circuits. Although the traditional bridge-based capacitive detection circuits widely used currently behave high accuracy, they have a relatively complex structure and higher power consumption. In this paper, a charge-discharge differential capacitive sensing circuit based on high stability square-wave generator, ring-diode switch and low noise trans-impedance amplifier is proposed and investigated systematically. The system noise model is presented based on detailed analysis and measurement of the main noise sources. Low noise design optimization scheme is proposed based on the noise model. A prototype circuit is developed and tested. The sensitivities with several different excitation frequencies are calibrated. The measured noise is compared to the theoretical model and demonstrates a good consistency. The experimental results show that the noise equivalent capacitance resolution of this circuit reaches 0.24 aF/Hz1/2 at 0.1 Hz and 0.028 aF/Hz1/2 at 100 Hz. Benefitting from its simple structure and high measurement accuracy, it is highly suitable for space exploration instruments and other applications.