David L. Guyton
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
David L. Guyton has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Boris I. Gramatikov
Wilmer Eye Institute, The Johns Hopkins University School of Medicine, Baltimore, MD, USA
7 shared publications - David G. Hunter
Department of Ophthalmology, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts
5 shared publications Deborah S. Nassif
Harvard Medical School, Children's Hospital Boston, Department of Ophthalmology, 300 Longwood Avenue, Boston, Massachusetts 02115, USA
2 shared publicationsKevin J. Nusz
Krieger Children's Eye Center at The Wilmer Institute, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
2 shared publications- Kristina Irsch
Vision Institute – Sorbonne University, INSERM, CNRS, 75012 Paris, France
2 shared publications Nadya V. Piskun
Harvard Medical School, Children’s Hospital Boston, Department of Ophthalmology, 300 Longwood Avenue, Boston, Massachusetts 02115
2 shared publications
Latest Publications
- 11 December 2022
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 248, 176
Comment on: Masquerading superior oblique palsy
- 11 December 2022
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 248, 176
Comment on: Masquerading superior oblique palsy
- 1 August 2019
- Published by Elsevier in Advances in Ophthalmology and Optometry
- Vol. 4, 89-100
Adjustable Suture Strabismus Surgery in Children
- 1 August 2019
- Published by Elsevier in Advances in Ophthalmology and Optometry
- Vol. 4, 89-100
Adjustable Suture Strabismus Surgery in Children
- Open Access
- 1 October 2014
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 19 (10) , 106014
Optimal timing of retinal scanning during dark adaptation, in the presence of fixation on a target: the role of pupil size dynamics
While validating our newly developed vision screener based on a double-pass retinal scanning system, we noticed that in all patients the signals from the retina were significantly higher when measurements were performed within a certain time interval referenced to the initial moment when the lights were dimmed and the test subject was asked to fixate on a target. This appeared to be most likely attributable to pupil size dynamics and triggered the present study, whose aim was to assess the pupillary “lights-off” response while fixating on a target in the presence of an accommodative effort. We found that pupil size increases in the first 60 to 70 s after turning off the room lights, and then it decreases toward the baseline in an exponential decay. Our results suggest that there is an optimal time window during which pupil size is expected to be maximal, that is during the second minute after dimming the room lights. During this time, window retinal diagnostic instruments based on double-pass measurement technology should deliver an optimal signal-to-noise ratio. We also propose a mathematical model that can be used to approximate the behavior of the normalized pupil size.
- 1 October 2014
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 19 (10) , 106014
Open AccessOptimal timing of retinal scanning during dark adaptation, in the presence of fixation on a target: the role of pupil size dynamics
While validating our newly developed vision screener based on a double-pass retinal scanning system, we noticed that in all patients the signals from the retina were significantly higher when measurements were performed within a certain time interval referenced to the initial moment when the lights were dimmed and the test subject was asked to fixate on a target. This appeared to be most likely attributable to pupil size dynamics and triggered the present study, whose aim was to assess the pupillary “lights-off” response while fixating on a target in the presence of an accommodative effort. We found that pupil size increases in the first 60 to 70 s after turning off the room lights, and then it decreases toward the baseline in an exponential decay. Our results suggest that there is an optimal time window during which pupil size is expected to be maximal, that is during the second minute after dimming the room lights. During this time, window retinal diagnostic instruments based on double-pass measurement technology should deliver an optimal signal-to-noise ratio. We also propose a mathematical model that can be used to approximate the behavior of the normalized pupil size.
- 1 August 2014
- Published by Elsevier in Journal of American Association for Pediatric Ophthalmology and Strabismus
- Vol. 18 (4) , 378-384
DVD—a conceptual, clinical, and surgical overview
- 1 August 2014
- Published by Elsevier in Journal of American Association for Pediatric Ophthalmology and Strabismus
- Vol. 18 (4) , 378-384
DVD—a conceptual, clinical, and surgical overview
- Open Access
- 1 June 2014
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 19 (6) , 067004
New pediatric vision screener employing polarization-modulated, retinal-birefringence-scanning-based strabismus detection and bull’s eye focus detection with an improved target system: opto-mechanical design and operation
Amblyopia (“lazy eye”) is a major public health problem, caused by misalignment of the eyes (strabismus) or defocus. If detected early in childhood, there is an excellent response to therapy, yet most children are detected too late to be treated effectively. Commercially available vision screening devices that test for amblyopia’s primary causes can detect strabismus only indirectly and inaccurately via assessment of the positions of external light reflections from the cornea, but they cannot detect the anatomical feature of the eyes where fixation actually occurs (the fovea). Our laboratory has been developing technology to detect true foveal fixation, by exploiting the birefringence of the uniquely arranged Henle fibers delineating the fovea using retinal birefringence scanning (RBS), and we recently described a polarization-modulated approach to RBS that enables entirely direct and reliable detection of true foveal fixation, with greatly enhanced signal-to-noise ratio and essentially independent of corneal birefringence (a confounding variable with all polarization-sensitive ophthalmic technology). Here, we describe the design and operation of a new pediatric vision screener that employs polarization-modulated, RBS-based strabismus detection and bull’s eye focus detection with an improved target system, and demonstrate the feasibility of this new approach.
- 1 June 2014
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 19 (6) , 067004
Open AccessNew pediatric vision screener employing polarization-modulated, retinal-birefringence-scanning-based strabismus detection and bull’s eye focus detection with an improved target system: opto-mechanical design and operation
Amblyopia (“lazy eye”) is a major public health problem, caused by misalignment of the eyes (strabismus) or defocus. If detected early in childhood, there is an excellent response to therapy, yet most children are detected too late to be treated effectively. Commercially available vision screening devices that test for amblyopia’s primary causes can detect strabismus only indirectly and inaccurately via assessment of the positions of external light reflections from the cornea, but they cannot detect the anatomical feature of the eyes where fixation actually occurs (the fovea). Our laboratory has been developing technology to detect true foveal fixation, by exploiting the birefringence of the uniquely arranged Henle fibers delineating the fovea using retinal birefringence scanning (RBS), and we recently described a polarization-modulated approach to RBS that enables entirely direct and reliable detection of true foveal fixation, with greatly enhanced signal-to-noise ratio and essentially independent of corneal birefringence (a confounding variable with all polarization-sensitive ophthalmic technology). Here, we describe the design and operation of a new pediatric vision screener that employs polarization-modulated, RBS-based strabismus detection and bull’s eye focus detection with an improved target system, and demonstrate the feasibility of this new approach.
- Open Access
- 1 January 2006
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 11 (3) , 034025-034025-11
Birefringence-based eye fixation monitor with no moving parts
For the purpose of vision screening, we develop an eye fixation monitor that detects the fovea by its unique radial orientation of birefringent Henle fibers. Polarized near-infrared light is reflected from the foveal area in a bow-tie pattern of polarization states, similar to the Haidinger brush phenomenon. In contrast to previous devices that used scanning systems, this instrument uses no moving parts. It rather utilizes four spots of linearly polarized light—two aligned with the “bright” arms and two aligned with the “dark” arms—of the bow-tie pattern surrounding the fovea. The light reflected from the fundus is imaged onto a quadrant photodetector, whereby the circular polarization component of the polarization state of each reflected patch of light is measured. The signals from the four photodetectors are amplified, digitized, and analyzed. A normalized differential signal is computed to detect central fixation. The algorithm is tested on a computer model, and the apparatus is tested on human subjects. This work demonstrates the feasibility of a fixation monitor with no moving parts.
- 1 January 2006
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 11 (3) , 034025-034025-11
Open AccessBirefringence-based eye fixation monitor with no moving parts
For the purpose of vision screening, we develop an eye fixation monitor that detects the fovea by its unique radial orientation of birefringent Henle fibers. Polarized near-infrared light is reflected from the foveal area in a bow-tie pattern of polarization states, similar to the Haidinger brush phenomenon. In contrast to previous devices that used scanning systems, this instrument uses no moving parts. It rather utilizes four spots of linearly polarized light—two aligned with the “bright” arms and two aligned with the “dark” arms—of the bow-tie pattern surrounding the fovea. The light reflected from the fundus is imaged onto a quadrant photodetector, whereby the circular polarization component of the polarization state of each reflected patch of light is measured. The signals from the four photodetectors are amplified, digitized, and analyzed. A normalized differential signal is computed to detect central fixation. The algorithm is tested on a computer model, and the apparatus is tested on human subjects. This work demonstrates the feasibility of a fixation monitor with no moving parts.
- 25 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 848-851
Hint for squint: a computer reliant diagnostic aid for strabismus
This paper provides an outline of methods used for the implementation of a computer reliant diagnostic aid in the medical specialty of Ophthalmology. Some problems have been associated with many previous diagnostic models. A careful review indicates that the most serious problems were: * inability to handle: - multiple diseases coexistent in the patient - partially described diseases - extraneous input symptoms - quantitative signs along with symptoms * inflexible and non-extendible prototype models * lack of inclusive physician-approved data banks The use of computer techniques developed for large scale wargaming has allowed the construction of an extendable prototype model. The hierarchical searching techniques used provided the necessary partial matching solution to the above set of computational problems. An active physician-analyst dialogue permitted the avoidance of the last problem, since the actual data and diagnostic logic was physician input.
- 25 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 848-851
Hint for squint: a computer reliant diagnostic aid for strabismus
This paper provides an outline of methods used for the implementation of a computer reliant diagnostic aid in the medical specialty of Ophthalmology. Some problems have been associated with many previous diagnostic models. A careful review indicates that the most serious problems were: * inability to handle: - multiple diseases coexistent in the patient - partially described diseases - extraneous input symptoms - quantitative signs along with symptoms * inflexible and non-extendible prototype models * lack of inclusive physician-approved data banks The use of computer techniques developed for large scale wargaming has allowed the construction of an extendable prototype model. The hierarchical searching techniques used provided the necessary partial matching solution to the above set of computational problems. An active physician-analyst dialogue permitted the avoidance of the last problem, since the actual data and diagnostic logic was physician input.
- 1 April 2005
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 31 (4) , 763-770
Rapid, objective detection of cataract-induced blur using a bull's eye photodetector
To determine whether optical aberrations caused by cataract can be detected and quantified objectively using a newly described focus detection system (FDS). The Wilmer Opthalmological Institute, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA. The FDS uses a bull's eye photodetector to measure the double-pass blur produced from a point source of light. To determine the range and level of focus, signals are measured with a series of trial lenses in the light path selected to span the point of best focus to generate focus curves. The best corrected visual acuity (BCVA), refractive error, lens photograph grades, and FDS signals were obtained in 18 patients scheduled to have cataract surgery. The tests were repeated 6 weeks after surgery. The mean FDS outcome measures improved after cataract surgery, with increased peak height (P=.001) and decreased peak width (P=.001). Improvement in signal strength (integral of signal within +/-1.5 diopters of the point of best focus) strongly correlated with improvement in peak height (R(2)=.88, P<.0001) and photographic cataract grade (R(2)=.72, P<.0001). The mean BCVA improved from 20/50 to 20/26 (P<.0001). The improvement in BCVA correlated more closely with FDS signal strength (R(2)=.44, P=.001) than with cataract grade (R(2)=.25, P=.06). Improvement in FDS outcome measures correlated with cataract severity and improvement in visual acuity. This objective approach may be useful in long-term studies of cataract progression.
- 1 April 2005
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 31 (4) , 763-770
Rapid, objective detection of cataract-induced blur using a bull's eye photodetector
To determine whether optical aberrations caused by cataract can be detected and quantified objectively using a newly described focus detection system (FDS). The Wilmer Opthalmological Institute, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA. The FDS uses a bull's eye photodetector to measure the double-pass blur produced from a point source of light. To determine the range and level of focus, signals are measured with a series of trial lenses in the light path selected to span the point of best focus to generate focus curves. The best corrected visual acuity (BCVA), refractive error, lens photograph grades, and FDS signals were obtained in 18 patients scheduled to have cataract surgery. The tests were repeated 6 weeks after surgery. The mean FDS outcome measures improved after cataract surgery, with increased peak height (P=.001) and decreased peak width (P=.001). Improvement in signal strength (integral of signal within +/-1.5 diopters of the point of best focus) strongly correlated with improvement in peak height (R(2)=.88, P<.0001) and photographic cataract grade (R(2)=.72, P<.0001). The mean BCVA improved from 20/50 to 20/26 (P<.0001). The improvement in BCVA correlated more closely with FDS signal strength (R(2)=.44, P=.001) than with cataract grade (R(2)=.25, P=.06). Improvement in FDS outcome measures correlated with cataract severity and improvement in visual acuity. This objective approach may be useful in long-term studies of cataract progression.
- Open Access
- 1 January 2004
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 9 (5) , 1103-1109
Automated detection of ocular focus
We characterize objectively the state of focus of the human eye, utilizing a bull’s eye photodetector to detect the double-pass blur produced from a point source of light. A point fixation source of light illuminates the eye. Fundus-reflected light is focused by the optical system of the eye onto a bull’s eye photodetector [consisting of an annulus (A) and a center (C) of approximately equal active area]. To generate focus curves, is measured with a range of trial lenses in the light path. Three human eyes and a model eye are studied. In the model eye, the focus curve showed a sharp peak with a full width at half maximum (FWHM) of ±0.25 D. In human eyes, the ratio was >4 at best focus in all cases, with a FWHM of ±1 D. The optical apparatus detects ocular focus (as opposed to refractive error) in real time. A device that can assess focus rapidly and objectively will make it possible to perform low-cost, mass screening for focusing problems such as may exist in children at risk for amblyopia. © 2004 Society of Photo-Optical Instrumentation Engineers.- 1 January 2004
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 9 (5) , 1103-1109
Open AccessAutomated detection of ocular focus
We characterize objectively the state of focus of the human eye, utilizing a bull’s eye photodetector to detect the double-pass blur produced from a point source of light. A point fixation source of light illuminates the eye. Fundus-reflected light is focused by the optical system of the eye onto a bull’s eye photodetector [consisting of an annulus (A) and a center (C) of approximately equal active area]. To generate focus curves, is measured with a range of trial lenses in the light path. Three human eyes and a model eye are studied. In the model eye, the focus curve showed a sharp peak with a full width at half maximum (FWHM) of ±0.25 D. In human eyes, the ratio was >4 at best focus in all cases, with a FWHM of ±1 D. The optical apparatus detects ocular focus (as opposed to refractive error) in real time. A device that can assess focus rapidly and objectively will make it possible to perform low-cost, mass screening for focusing problems such as may exist in children at risk for amblyopia. © 2004 Society of Photo-Optical Instrumentation Engineers. - Open Access
- 1 January 2004
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 9 (6) , 1369-1374
Pediatric Vision Screener 2: pilot study in adults
Amblyopia is a form of visual impairment caused by ocular misalignment (strabismus) or defocus in an otherwise healthy eye. If detected early, the condition can be fully treated, yet over half of all children with amblyopia under age 5 escape detection. We developed a Pediatric Vision Screener (PVS) to detect amblyopia risk factors. This instrument produces a binocularity score to indicate alignment and a focus score to indicate focus. The purpose of this study is to assess the performance of the PVS by testing adults who were fully cooperative for testing. The study group includes 40 subjects (20 controls, 20 patients) aged 22 to 79 years. 12 patients had constant strabismus (8 to 50Δ), and eight had variable strabismus (12 to 55Δ). All controls had binocularity scores >50%. Binocularity was 50% had a well-controlled intermittent exotropia and was not at risk for amblyopia. Focus scores were highly sensitive for good focus but not specific. The PVS shows high sensitivity and specificity for detection of strabismus in adults. Future studies will determine whether this performance can be achieved in preschool children, who are at greatest risk for vision loss. © 2004 Society of Photo-Optical Instrumentation Engineers.
- 1 January 2004
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 9 (6) , 1369-1374
Open AccessPediatric Vision Screener 2: pilot study in adults
Amblyopia is a form of visual impairment caused by ocular misalignment (strabismus) or defocus in an otherwise healthy eye. If detected early, the condition can be fully treated, yet over half of all children with amblyopia under age 5 escape detection. We developed a Pediatric Vision Screener (PVS) to detect amblyopia risk factors. This instrument produces a binocularity score to indicate alignment and a focus score to indicate focus. The purpose of this study is to assess the performance of the PVS by testing adults who were fully cooperative for testing. The study group includes 40 subjects (20 controls, 20 patients) aged 22 to 79 years. 12 patients had constant strabismus (8 to 50Δ), and eight had variable strabismus (12 to 55Δ). All controls had binocularity scores >50%. Binocularity was 50% had a well-controlled intermittent exotropia and was not at risk for amblyopia. Focus scores were highly sensitive for good focus but not specific. The PVS shows high sensitivity and specificity for detection of strabismus in adults. Future studies will determine whether this performance can be achieved in preschool children, who are at greatest risk for vision loss. © 2004 Society of Photo-Optical Instrumentation Engineers.