Rapid, objective detection of cataract-induced blur using a bull's eye photodetector
- 1 April 2005
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 31 (4) , 763-770
Abstract
To determine whether optical aberrations caused by cataract can be detected and quantified objectively using a newly described focus detection system (FDS). The Wilmer Opthalmological Institute, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA. The FDS uses a bull's eye photodetector to measure the double-pass blur produced from a point source of light. To determine the range and level of focus, signals are measured with a series of trial lenses in the light path selected to span the point of best focus to generate focus curves. The best corrected visual acuity (BCVA), refractive error, lens photograph grades, and FDS signals were obtained in 18 patients scheduled to have cataract surgery. The tests were repeated 6 weeks after surgery. The mean FDS outcome measures improved after cataract surgery, with increased peak height (P=.001) and decreased peak width (P=.001). Improvement in signal strength (integral of signal within +/-1.5 diopters of the point of best focus) strongly correlated with improvement in peak height (R(2)=.88, P<.0001) and photographic cataract grade (R(2)=.72, P<.0001). The mean BCVA improved from 20/50 to 20/26 (P<.0001). The improvement in BCVA correlated more closely with FDS signal strength (R(2)=.44, P=.001) than with cataract grade (R(2)=.25, P=.06). Improvement in FDS outcome measures correlated with cataract severity and improvement in visual acuity. This objective approach may be useful in long-term studies of cataract progression.Keywords
This publication has 15 references indexed in Scilit:
- Automated detection of ocular focusJournal of Biomedical Optics, 2004
- Visual Performance and Objectively Measured Grades of Cataract. A Correlation of Methods Designed for Use in Longitudinal TrialsOptometry and Vision Science, 1993
- Evaluating Visual Function in CataractOptometry and Vision Science, 1993
- Comparison of Acuity, Contrast Sensitivity, and Disability Glare Before and After Cataract SurgeryArchives of Ophthalmology (1950), 1993
- The morphology of cataract and visual performanceEye, 1993
- Comparing clinical tests of visual function in cataract with the patient's perceived visual disabilityEye, 1990
- Lens Opacities Classification System II (LOCS II)Archives of Ophthalmology (1950), 1989
- Glare and contrast sensitivity testing in cataract patientsJournal of Cataract & Refractive Surgery, 1989
- Determination of the point-spread function of human eyes using a hybrid optical–digital methodJournal of the Optical Society of America A, 1987
- Brightness acuity test and outdoor visual acuity in cataract patientsJournal of Cataract & Refractive Surgery, 1987