Wensong Jiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wensong Jiang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Changcheng Shi
Zhejiang International Scientific and Technological Cooperative Base of Biomedical Materials and Technology Zhejiang Engineering Research Center for Biomedical Materials Laboratory of Advanced Theranostic Materials and Technology Ningbo Institute of Materials Technology and Engineering Chinese Academy of Sciences Ningbo People's Republic of China
1 shared publication - Guokun Zuo
Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo, Zhejiang, China
1 shared publication - Hao Chen
Cixi Biomedical Research Institute, Wenzhou Medical University, Ningbo, Zhejiang, China
1 shared publication - Huilin Zhou
Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, China
1 shared publication - Jiajia Wu
Cixi Biomedical Research Institute, Wenzhou Medical University, Ningbo, Zhejiang, China
1 shared publication - Li Li
Ningbo NO.2 hospital, China
1 shared publication
Latest Publications
- 20 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (7) , 2265-2275
Short Step Length Estimation for Parkinson's Disease Patients by Using Fusion Data From Camera-IMU in Smart Glasses
Shortened step length is a prominent motor abnormality in Parkinson's disease (PD) patients. Current methods for estimating short step length have the limitation of relying on laboratory scenarios, wearing multiple sensors, and inaccurate estimation results from a single sensor. In this paper, we proposed a novel method for estimating short step length for PD patients by fusing data from camera and inertial measurement units in smart glasses. A simultaneous localization and mapping technique and acceleration thresholding-based step detection technique were combined to realize the step length estimation. Two sets of experiments were conducted to demonstrate the performance of our method. In the first set of experiments with 12 healthy subjects, the proposed method demonstrated an average error of 8.44% across all experiments including six fixed step lengths below 30 cm. The second set of straightly walking experiments were implemented with 12 PD patients, the proposed method exhibited an average error of 4.27% compared to a standard gait evaluation technique in total walking distance. Notably, among the results of step lengths below 40 cm, our method agreed with the standard technique (R ${^{2}}$ =0.8659). This study offers a promising approach for estimating short step length for PD patients during smart glasses-based gait training.
- 20 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (7) , 2265-2275
Short Step Length Estimation for Parkinson's Disease Patients by Using Fusion Data From Camera-IMU in Smart Glasses
Shortened step length is a prominent motor abnormality in Parkinson's disease (PD) patients. Current methods for estimating short step length have the limitation of relying on laboratory scenarios, wearing multiple sensors, and inaccurate estimation results from a single sensor. In this paper, we proposed a novel method for estimating short step length for PD patients by fusing data from camera and inertial measurement units in smart glasses. A simultaneous localization and mapping technique and acceleration thresholding-based step detection technique were combined to realize the step length estimation. Two sets of experiments were conducted to demonstrate the performance of our method. In the first set of experiments with 12 healthy subjects, the proposed method demonstrated an average error of 8.44% across all experiments including six fixed step lengths below 30 cm. The second set of straightly walking experiments were implemented with 12 PD patients, the proposed method exhibited an average error of 4.27% compared to a standard gait evaluation technique in total walking distance. Notably, among the results of step lengths below 40 cm, our method agreed with the standard technique (R ${^{2}}$ =0.8659). This study offers a promising approach for estimating short step length for PD patients during smart glasses-based gait training.