Miaotian Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Miaotian Wang has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Kaisheng Lin
School of Electronics, Peking University 1 , Beijing 100871
3 shared publications - Weimin Wang
Peking University
2 shared publications - Yaohui Wang
Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing, China
2 shared publications - Feng Liu
University of Queensland
1 shared publication - Hongwei Li
Beijing NMR Center College of Chemistry and Molecular Engineering Peking University Beijing China
1 shared publication - Jinhao Liu
School of Electrical Engineering, Xi'an Jiaotong University, Xi'an, China
1 shared publication
Latest Publications
- 15 November 2026
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 393
Cost-effective 0.5 T benchtop NMR/MRI system with spatial inhomogeneity compensation and digital field-frequency lock
- 15 November 2026
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 393
Cost-effective 0.5 T benchtop NMR/MRI system with spatial inhomogeneity compensation and digital field-frequency lock
- 1 March 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (3)
A multi-channel MRI console for ultra-high field up to 14 T
Ultra-high field magnetic resonance imaging (MRI) offers significant advantages in terms of signal-to-noise ratio and spatial resolution. In this study, we detail the development of a multi-channel home-built MRI console operating at 14 T. We propose a hybrid analog–digital framework that shifts high-frequency radio frequency transmission and reception issues to lower frequencies, utilizing software-defined radio technology to process these low-frequency signals. Digital pre-emphasis is used in gradient calculations to counteract the effects of eddy currents during gradient switching. Our console can transmit and receive at center frequencies up to 600 MHz. The pulse programmer module achieves a timing resolution of 20 ns, while the transmitter can independently generate waveforms with varying amplitude, frequency, phase, and envelope. The receiver’s dual-stage gain control provides 63 dB of adjustable range, optimizing the magnetic resonance (MR) signal’s dynamic range. After frequency conversion, the MR signals are digitized with 16-bit resolution and 100 MHz sampling rate. High-resolution water phantom images are acquired on the 14 T Bruker Ascend 600 nuclear magnetic resonance magnet, demonstrating its potential for clinical research and application.
- 1 March 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (3)
A multi-channel MRI console for ultra-high field up to 14 T
Ultra-high field magnetic resonance imaging (MRI) offers significant advantages in terms of signal-to-noise ratio and spatial resolution. In this study, we detail the development of a multi-channel home-built MRI console operating at 14 T. We propose a hybrid analog–digital framework that shifts high-frequency radio frequency transmission and reception issues to lower frequencies, utilizing software-defined radio technology to process these low-frequency signals. Digital pre-emphasis is used in gradient calculations to counteract the effects of eddy currents during gradient switching. Our console can transmit and receive at center frequencies up to 600 MHz. The pulse programmer module achieves a timing resolution of 20 ns, while the transmitter can independently generate waveforms with varying amplitude, frequency, phase, and envelope. The receiver’s dual-stage gain control provides 63 dB of adjustable range, optimizing the magnetic resonance (MR) signal’s dynamic range. After frequency conversion, the MR signals are digitized with 16-bit resolution and 100 MHz sampling rate. High-resolution water phantom images are acquired on the 14 T Bruker Ascend 600 nuclear magnetic resonance magnet, demonstrating its potential for clinical research and application.
- 20 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (8) , 2462-2473
Design, Fabrication and Test of a Lightweight 3.0 T Cryogen-Free MRI System With GM Refrigerator for Imaging Small Animals and Materials
Objective: To construct and evaluate a lightweight, high-performance and cost-effective 3.0 T MRI system with enhanced spatiotemporal magnetic field characteristics for advanced imaging applications. Methods: A lightweight 3.0 T cryogen-free magnet weighing $\sim$1100 kg was developed. Key optimizations included conduction-cooled pathway, vibration isolation, mechanical damping, and structural stability to ensure long-term magnetic field stability. Customized imaging sequences incorporated navigator echo corrections were developed to address residual vibrations. A gradient coil was designed with 200 mT/m peak amplitude and advanced shielding to minimize magnet-coil interactions. Passive shimming and active shim coils were integrated to improve spatial magnetic field homogeneity. Results: The 5 Gauss line of the superconducting magnet was constrained to 1.80 m × 1.20 m. Temporal magnetic field fluctuations were reduced by 99.81%, decreasing from 2.168 $µ$ T to 0.004 $µ$ T. Passive shimming achieved spatial peak-to-peak and root mean square error (RMSE) homogeneity of 22.41 parts per million (ppm) and 3.69 ppm over a 180 mm diameter of spherical volume (DSV), with further improvements to 4.18 ppm and 1.02 ppm through active shim coils. Gradient shield coils confined stray fields to 1.2 Gauss and reduced residual eddy fields. A complete MRI system was constructed with a home-built console and a radio frequency (RF) coil. High-resolution imaging of the mouse brain and detailed analysis of plastic parts and porous media were achieved, with accelerated algorithms reducing scan times significantly. Conclusion: The newly developed 3.0 T MRI system demonstrates superior spatiotemporal magnetic field stability and imaging capabilities. It offers significant improvements in image quality and resolution for various applications, including small animal studies and material characterization. Significance: The enhanced performance of this cryogen-free MR system represents a significant advancement in brain science, plastics, and porous media imaging technology.
- 20 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (8) , 2462-2473
Design, Fabrication and Test of a Lightweight 3.0 T Cryogen-Free MRI System With GM Refrigerator for Imaging Small Animals and Materials
Objective: To construct and evaluate a lightweight, high-performance and cost-effective 3.0 T MRI system with enhanced spatiotemporal magnetic field characteristics for advanced imaging applications. Methods: A lightweight 3.0 T cryogen-free magnet weighing $\sim$1100 kg was developed. Key optimizations included conduction-cooled pathway, vibration isolation, mechanical damping, and structural stability to ensure long-term magnetic field stability. Customized imaging sequences incorporated navigator echo corrections were developed to address residual vibrations. A gradient coil was designed with 200 mT/m peak amplitude and advanced shielding to minimize magnet-coil interactions. Passive shimming and active shim coils were integrated to improve spatial magnetic field homogeneity. Results: The 5 Gauss line of the superconducting magnet was constrained to 1.80 m × 1.20 m. Temporal magnetic field fluctuations were reduced by 99.81%, decreasing from 2.168 $µ$ T to 0.004 $µ$ T. Passive shimming achieved spatial peak-to-peak and root mean square error (RMSE) homogeneity of 22.41 parts per million (ppm) and 3.69 ppm over a 180 mm diameter of spherical volume (DSV), with further improvements to 4.18 ppm and 1.02 ppm through active shim coils. Gradient shield coils confined stray fields to 1.2 Gauss and reduced residual eddy fields. A complete MRI system was constructed with a home-built console and a radio frequency (RF) coil. High-resolution imaging of the mouse brain and detailed analysis of plastic parts and porous media were achieved, with accelerated algorithms reducing scan times significantly. Conclusion: The newly developed 3.0 T MRI system demonstrates superior spatiotemporal magnetic field stability and imaging capabilities. It offers significant improvements in image quality and resolution for various applications, including small animal studies and material characterization. Significance: The enhanced performance of this cryogen-free MR system represents a significant advancement in brain science, plastics, and porous media imaging technology.