Yaohui Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Yaohui Wang has a total of 208 co-authors. Here are the top co-authors by number of shared publications:
- Qiuliang Wang
Chinese Academy of Sciences
29 shared publications - Feng Liu
University of Queensland
26 shared publications Feng Liu
School of Information Technology and Electrical Engineering, The University of Queensland, St Lucia, Brisbane, QLD 4072, Australia
13 shared publicationsHui Wang
Chinese Academy of Sciences
12 shared publicationsWenhui Yang
Institute of Electrical Engineering, Chinese Academy of Sciences 4 , Beijing 100190
11 shared publicationsShunzhong Chen
Chinese Academy of Sciences
10 shared publications
Latest Publications
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Design and experimental evaluation of a small-size, high-precision nuclear magnetic resonance probe for enlarged magnetic field measurement region on small-bore magnetic resonance imaging magnets
High-quality magnetic resonance imaging (MRI) relies on accurate magnetic field characterization; however, commercial nuclear magnetic resonance (NMR) magnetic field probes are often limited in boundary-accessible field mapping for bore-constrained magnets. In this study, a miniature free-induction-decay-based NMR magnetic field probe was developed, integrating a solenoid microcoil, a compact tuning/matching network, and a liquid sample unit, with a maximum width of ∼8 mm. Compared with a commercial NMR reference probe, the developed microprobe showed close agreement in single-point validation and yielded a mean absolute deviation of 0.27 μT in axial comparison measurements (corresponding to 0.039 ppm at 7 T), confirming its field-measurement accuracy and spatial tracking capability. Temperature-sensitivity tests over a range of 15–35 °C showed that the repeated-measurement standard deviation remained within 0.019–0.046 ppm, indicating good measurement stability. In wall-adjacent measurements inside a 172 mm-bore magnet, the maximum accessible trajectory diameter increased from 152 to 164 mm, corresponding to a 7.9% improvement in an accessible mapping range. Spherical-surface mapping of a 50 mm diameter spherical volume further yields a mean absolute deviation of 0.143 μT and a Pearson correlation coefficient greater than 0.99. These results demonstrate that the proposed microprobe provides a low-cost, stable, high-precision, and broadly applicable solution for extending accessible magnetic field mapping in bore-constrained MRI magnets.
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Design and experimental evaluation of a small-size, high-precision nuclear magnetic resonance probe for enlarged magnetic field measurement region on small-bore magnetic resonance imaging magnets
High-quality magnetic resonance imaging (MRI) relies on accurate magnetic field characterization; however, commercial nuclear magnetic resonance (NMR) magnetic field probes are often limited in boundary-accessible field mapping for bore-constrained magnets. In this study, a miniature free-induction-decay-based NMR magnetic field probe was developed, integrating a solenoid microcoil, a compact tuning/matching network, and a liquid sample unit, with a maximum width of ∼8 mm. Compared with a commercial NMR reference probe, the developed microprobe showed close agreement in single-point validation and yielded a mean absolute deviation of 0.27 μT in axial comparison measurements (corresponding to 0.039 ppm at 7 T), confirming its field-measurement accuracy and spatial tracking capability. Temperature-sensitivity tests over a range of 15–35 °C showed that the repeated-measurement standard deviation remained within 0.019–0.046 ppm, indicating good measurement stability. In wall-adjacent measurements inside a 172 mm-bore magnet, the maximum accessible trajectory diameter increased from 152 to 164 mm, corresponding to a 7.9% improvement in an accessible mapping range. Spherical-surface mapping of a 50 mm diameter spherical volume further yields a mean absolute deviation of 0.143 μT and a Pearson correlation coefficient greater than 0.99. These results demonstrate that the proposed microprobe provides a low-cost, stable, high-precision, and broadly applicable solution for extending accessible magnetic field mapping in bore-constrained MRI magnets.
- 1 July 2026
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 39 (7) , 073002
Magnetic resonance imaging and linear accelerator hybrid instrument technology: magnet, accelerator, treatment plan and medical applications
Magnetic resonance–guided radiotherapy (MRgRT) provides high-contrast soft-tissue imaging, continuous or near-real-time visualization of anatomical structures, and online adaptive treatment planning, demonstrating significant advantages over conventional computed tomography-guided radiotherapy in target localization accuracy, organ motion management, and dosimetric controllability. Meanwhile, the strong static magnetic field leads to deep coupling among the magnet, accelerator, and radiation transport, posing a series of unique challenges in system engineering and medical physics. Focusing on magnetic resonance linear accelerator (MRI-LINAC) systems, this paper reviews the current status and research progress of key MRgRT technologies from the perspectives of superconducting magnet technology, linear accelerators, treatment planning systems, and medical applications. Finally, future development trends in magnet engineering, dose transport modeling, and clinical application expansion are discussed.
- 1 July 2026
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 39 (7) , 073002
Magnetic resonance imaging and linear accelerator hybrid instrument technology: magnet, accelerator, treatment plan and medical applications
Magnetic resonance–guided radiotherapy (MRgRT) provides high-contrast soft-tissue imaging, continuous or near-real-time visualization of anatomical structures, and online adaptive treatment planning, demonstrating significant advantages over conventional computed tomography-guided radiotherapy in target localization accuracy, organ motion management, and dosimetric controllability. Meanwhile, the strong static magnetic field leads to deep coupling among the magnet, accelerator, and radiation transport, posing a series of unique challenges in system engineering and medical physics. Focusing on magnetic resonance linear accelerator (MRI-LINAC) systems, this paper reviews the current status and research progress of key MRgRT technologies from the perspectives of superconducting magnet technology, linear accelerators, treatment planning systems, and medical applications. Finally, future development trends in magnet engineering, dose transport modeling, and clinical application expansion are discussed.
- 19 May 2026
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 132, 110701
Small-bore gradient coil design with plate-rolling error correction for use in micro-MRI
- 19 May 2026
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 132, 110701
Small-bore gradient coil design with plate-rolling error correction for use in micro-MRI
- 6 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (4) , 4401707
Comparison of Passive Shimming Strategies: Overall versus Odd-Even Shim Tray Operation in a 3T Animal MRI Superconducting Magnet
The image quality and spectral accuracy of magnetic resonance imaging (MRI) are highly dependent on the homogeneity of the static magnetic field (B0). In compact 3 T animal MRI systems, susceptibility effects and geometric constraints tend to amplify magnetic field distortions, making efficient shimming particularly essential. Passive shimming corrects field inhomogeneity by strategically placing ferromagnetic materials in shim trays, offering advantages such as structural simplicity and low cost. However, the relative performance of various passive shimming strategies has not been systematically evaluated. In this study, we compared two typical passive shimming methods using a 3 T animal MRI superconducting magnet: 1) Odd-even progressive shimming method, in which the odd and even shim trays are adjusted alternatively in two successive rounds (method I), and 2) overall iterative shimming method, where all shim trays are optimized simultaneously in each round with iterative refinement based on prior results (method II). Magnetic field mapping and quantitative analysis were used to assess shimming performance. The results indicate that the overall iterative method provides higher efficiency. After two rounds, field inhomogeneity decreased from 1174.63 ppm to 87.37 ppm using method I, while method II achieved 54.30 ppm—a 37.8% improvement. Theoretically, method II can reduce residual inhomogeneity to approximately 5.91 ppm, indicating higher theoretical shimming potential for the present compact small-bore magnet. The overall iterative method is recommended as an effective and practical solution for improving magnetic field homogeneity and image quality in compact animal MRI systems.
- 6 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (4) , 4401707
Comparison of Passive Shimming Strategies: Overall versus Odd-Even Shim Tray Operation in a 3T Animal MRI Superconducting Magnet
The image quality and spectral accuracy of magnetic resonance imaging (MRI) are highly dependent on the homogeneity of the static magnetic field (B0). In compact 3 T animal MRI systems, susceptibility effects and geometric constraints tend to amplify magnetic field distortions, making efficient shimming particularly essential. Passive shimming corrects field inhomogeneity by strategically placing ferromagnetic materials in shim trays, offering advantages such as structural simplicity and low cost. However, the relative performance of various passive shimming strategies has not been systematically evaluated. In this study, we compared two typical passive shimming methods using a 3 T animal MRI superconducting magnet: 1) Odd-even progressive shimming method, in which the odd and even shim trays are adjusted alternatively in two successive rounds (method I), and 2) overall iterative shimming method, where all shim trays are optimized simultaneously in each round with iterative refinement based on prior results (method II). Magnetic field mapping and quantitative analysis were used to assess shimming performance. The results indicate that the overall iterative method provides higher efficiency. After two rounds, field inhomogeneity decreased from 1174.63 ppm to 87.37 ppm using method I, while method II achieved 54.30 ppm—a 37.8% improvement. Theoretically, method II can reduce residual inhomogeneity to approximately 5.91 ppm, indicating higher theoretical shimming potential for the present compact small-bore magnet. The overall iterative method is recommended as an effective and practical solution for improving magnetic field homogeneity and image quality in compact animal MRI systems.
- 22 April 2026
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (6) , e70298
Robust Magnetic Field Homogeneity Enhancement via Local Passive Shimming in a Superconducting Magnet for Animal MRI
In ultrahigh‐field magnetic resonance imaging (MRI) systems, achieving subppm static magnetic field homogeneity is critical. However, engineering tolerances and assembly errors often introduce complex field inhomogeneities that global shimming alone cannot always fully correct. In this study, a novel local passive shimming method is developed for small‐bore MRI superconducting magnets. By establishing a linear programming model for local shimming, the approach enables region‐specific correction of high‐order field variations. Numerical simulations and experimental verification on a 7 T/300‐mm superconducting magnet demonstrate significant improvements in homogeneity, reducing root mean square error (RMSE) and peak‐to‐peak variation across the diameter of spherical volume (DSV). The optimized shim configuration achieved a peak‐to‐peak inhomogeneity of 4.23 ppm within the DSV, indicating substantial enhancement over baseline performance. These results indicate that the proposed technique serves as a practical and efficient complement to global shimming strategies, offering a robust solution for field correction in small‐bore MRI systems.
- 22 April 2026
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (6) , e70298
Robust Magnetic Field Homogeneity Enhancement via Local Passive Shimming in a Superconducting Magnet for Animal MRI
In ultrahigh‐field magnetic resonance imaging (MRI) systems, achieving subppm static magnetic field homogeneity is critical. However, engineering tolerances and assembly errors often introduce complex field inhomogeneities that global shimming alone cannot always fully correct. In this study, a novel local passive shimming method is developed for small‐bore MRI superconducting magnets. By establishing a linear programming model for local shimming, the approach enables region‐specific correction of high‐order field variations. Numerical simulations and experimental verification on a 7 T/300‐mm superconducting magnet demonstrate significant improvements in homogeneity, reducing root mean square error (RMSE) and peak‐to‐peak variation across the diameter of spherical volume (DSV). The optimized shim configuration achieved a peak‐to‐peak inhomogeneity of 4.23 ppm within the DSV, indicating substantial enhancement over baseline performance. These results indicate that the proposed technique serves as a practical and efficient complement to global shimming strategies, offering a robust solution for field correction in small‐bore MRI systems.
- 6 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (7) , 4005308
Fabrication and Test of a Curved-Canted-Cosine-Theta Magnet Used for a Laser-Driven Proton Accelerator System
Proton therapy (PT) is a precise and efficient form of radiotherapy that can accurately target lesions to destroy tumor cells while minimizing damage to surrounding healthy tissues. Peking University has initiated a project to develop a laser-driven proton accelerator system. This paper reports a curved Canted-Cosine-Theta (CCT) magnet, which is a critical component in the proton accelerator system. The CCT superconducting magnet was designed with a curved dipole magnet and two quadrupole CCT magnets nested symmetrically at the dipole magnet ends. The curved CCT magnet has a bending radius of 1000 mm, with tilt angles of 30° and 45° for the dipole and quadrupole magnets, respectively. The dipole magnet was used to generate a 2.5T transverse magnetic field in a 63-mm warm bore, and the quadrupole magnets were used to generate a 20T/m gradient magnetic field at both ends of the magnet. The whole magnet was wound with NbTi superconducting wire, with an operating current of 380A. In this paper, the magnet manufacturing process and testing are presented.
- 6 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (7) , 4005308
Fabrication and Test of a Curved-Canted-Cosine-Theta Magnet Used for a Laser-Driven Proton Accelerator System
Proton therapy (PT) is a precise and efficient form of radiotherapy that can accurately target lesions to destroy tumor cells while minimizing damage to surrounding healthy tissues. Peking University has initiated a project to develop a laser-driven proton accelerator system. This paper reports a curved Canted-Cosine-Theta (CCT) magnet, which is a critical component in the proton accelerator system. The CCT superconducting magnet was designed with a curved dipole magnet and two quadrupole CCT magnets nested symmetrically at the dipole magnet ends. The curved CCT magnet has a bending radius of 1000 mm, with tilt angles of 30° and 45° for the dipole and quadrupole magnets, respectively. The dipole magnet was used to generate a 2.5T transverse magnetic field in a 63-mm warm bore, and the quadrupole magnets were used to generate a 20T/m gradient magnetic field at both ends of the magnet. The whole magnet was wound with NbTi superconducting wire, with an operating current of 380A. In this paper, the magnet manufacturing process and testing are presented.
- 5 March 2026
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 129, 110654
Actively shielded gradient coil design for an all-superconducting planar MRI system using progressively-enhanced shielding constraints
- 5 March 2026
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 129, 110654
Actively shielded gradient coil design for an all-superconducting planar MRI system using progressively-enhanced shielding constraints
- 8 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-6
Passive Shimming of a 7T Cryogen-Free MRI Superconducting Magnet via Iron Strip Arrangement
The conventional iron matrix shimming method is highly sensitive to the positional variations, especially in small-aperture magnets where limited space imposes significant constraints on feasibility and precision. To address these challenges, this work studied an iron-strip shimming approach following superconducting shimming, replacing the traditional iron matrix scheme for a 7 T/54 mm micro-imaging MRI magnet. A key objective was to realize a 30 mm magnetic field homogenous area, three times larger than that of the typical 10 mm region in common nuclear magnetic resonance (NMR) magnets. To conserve space and leaving enough room for small animal placement, iron strips were positioned around the outer periphery of the gradient assembly, with the iron thickness limited to remain below 0.2 mm, ensuring no interference with gradient assembly installation. This configuration minimized mutual interactions among the iron strips and maximized field homogeneity. Experimental results showed that the peak-peak field homogeneity improved from 11.12 ppm to 4.82 ppm, presenting a 56% enhancement. Additionally, the sensitivity analysis predicted that the post-shimming magnetic field deviation due to assembly errors would remain below 0.1 ppm, demonstrating the method's robustness. This approach provides greater flexibility and ease of implementation than traditional methods, offering a reliable solution for small-aperture MRI superconducting magnets. Future work will focus on further reduction of field inhomogeneity (e.g., 2–3 ppm) for enhanced imaging precision.
- 8 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-6
Passive Shimming of a 7T Cryogen-Free MRI Superconducting Magnet via Iron Strip Arrangement
The conventional iron matrix shimming method is highly sensitive to the positional variations, especially in small-aperture magnets where limited space imposes significant constraints on feasibility and precision. To address these challenges, this work studied an iron-strip shimming approach following superconducting shimming, replacing the traditional iron matrix scheme for a 7 T/54 mm micro-imaging MRI magnet. A key objective was to realize a 30 mm magnetic field homogenous area, three times larger than that of the typical 10 mm region in common nuclear magnetic resonance (NMR) magnets. To conserve space and leaving enough room for small animal placement, iron strips were positioned around the outer periphery of the gradient assembly, with the iron thickness limited to remain below 0.2 mm, ensuring no interference with gradient assembly installation. This configuration minimized mutual interactions among the iron strips and maximized field homogeneity. Experimental results showed that the peak-peak field homogeneity improved from 11.12 ppm to 4.82 ppm, presenting a 56% enhancement. Additionally, the sensitivity analysis predicted that the post-shimming magnetic field deviation due to assembly errors would remain below 0.1 ppm, demonstrating the method's robustness. This approach provides greater flexibility and ease of implementation than traditional methods, offering a reliable solution for small-aperture MRI superconducting magnets. Future work will focus on further reduction of field inhomogeneity (e.g., 2–3 ppm) for enhanced imaging precision.
- 1 October 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (10)
A hybrid gradient coil design method generating ultra-high gradient magnetic field for micro-MRI utilization
Ultra-high gradient strength is crucial for achieving high spatial resolution in advanced magnetic resonance imaging (MRI) applications. However, it is challenging to design gradient coils to generate ultra-high gradient strengths with superior coil operational efficiency in a limited space. In this work, we propose an innovative hybrid gradient coil design approach that synergistically integrates the discrete wire scheme with the current density technique. The primary coils are configured using a discrete wire technique that achieves a compact and high-density winding structure, generating exceptional gradient field intensity. Concurrently, the shielding layer utilizes the current density method and stream function to effectively constrain stray magnetic fields and eddy current effects. Comparative analysis with conventional gradient coils demonstrates that the hybrid design approach achieves a doubling of gradient strength (e.g., 2450 vs 1000 mT/m) and a quadrupling of efficiency (e.g., 49 vs 12 mT/m/A). Furthermore, the mechanical design is also analyzed to ensure structural integrity and manufacturability. This novel design method provides new insights into overcoming the trade-offs among gradient performance metrics, establishing a promising approach for developing new-generation high-resolution MRI systems.
- 1 October 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (10)
A hybrid gradient coil design method generating ultra-high gradient magnetic field for micro-MRI utilization
Ultra-high gradient strength is crucial for achieving high spatial resolution in advanced magnetic resonance imaging (MRI) applications. However, it is challenging to design gradient coils to generate ultra-high gradient strengths with superior coil operational efficiency in a limited space. In this work, we propose an innovative hybrid gradient coil design approach that synergistically integrates the discrete wire scheme with the current density technique. The primary coils are configured using a discrete wire technique that achieves a compact and high-density winding structure, generating exceptional gradient field intensity. Concurrently, the shielding layer utilizes the current density method and stream function to effectively constrain stray magnetic fields and eddy current effects. Comparative analysis with conventional gradient coils demonstrates that the hybrid design approach achieves a doubling of gradient strength (e.g., 2450 vs 1000 mT/m) and a quadrupling of efficiency (e.g., 49 vs 12 mT/m/A). Furthermore, the mechanical design is also analyzed to ensure structural integrity and manufacturability. This novel design method provides new insights into overcoming the trade-offs among gradient performance metrics, establishing a promising approach for developing new-generation high-resolution MRI systems.
- 27 September 2025
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 381, 107969
Passive shimming performance in 3 T MRI systems: Influence of shim parameters under varying magnet field distributions
- 27 September 2025
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 381, 107969
Passive shimming performance in 3 T MRI systems: Influence of shim parameters under varying magnet field distributions