Barkhia Yunas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Barkhia Yunas has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Dyla Midya Octavia
Universitas Adzkia
3 shared publicationsWiwin Putri Zayu
Universitas Adzkia
3 shared publicationsYuni Purnama Syafri
Universitas Adzkia
3 shared publicationsErnawati Ernawati
Universitas Adzkia
2 shared publications- Mutia Alius
Universitas Adzkia
2 shared publications Rehan Putra Saira
Universitas Adzkia
2 shared publications
Latest Publications
- Open Access
- 30 July 2025
- Published by Universitas Wijaya Kusuma Surabaya in axial : jurnal rekayasa dan manajemen konstruksi
- Vol. 13 (2) , 220-231
PERANCANGAN STRUKTUR GEDUNG KANTOR UNIVERSITAS ADZKIA KOTA PADANG DENGAN SISTEM GANDA SESUAI SNI GEMPA 1726:2019
Kota Padang merupakan wilayah dengan tingkat aktivitas seismik yang tinggi, sehingga memerlukan desain struktur bangunan yang adaptif dan andal terhadap beban gempa. Perancangan ini bertujuan merancang struktur Gedung Universitas Adzkia berlantai enam menggunakan Sistem Ganda sesuai ketentuan SNI 1726:2019 dan SNI 2847:2019. Metodologi perancangan meliputi studi literatur untuk menentukan sistem struktur yang tepat, perencanaan awal (preliminary design), pemodelan 3D menggunakan software ETABS v.18 dengan penambahan elemen shear wall, serta analisis struktur terhadap kombinasi pembebanan mengacu pada ketentuan desain Sistem Ganda dan metode dinamik respons spektrum. Hasil analisis menunjukkan bahwa struktur memenuhi seluruh persyaratan desain gempa, dengan faktor koreksi skala terhadap gaya geser dinamis terhadap statis sebesar 1644,98 kN, partisipasi massa melebihi 90persen, simpangan antar lantai di bawah batas 0,002h, serta stabil terhadap pengaruh efek P-Delta. Pada arah X, nilai interstory drift ratio (teta) tertinggi terjadi di lantai 3 sebesar 0,0177 rad dan terendah di atap sebesar 0,0022 rad, sedangkan pada arah Y, nilai tertinggi sebesar 0,0161 rad dan terendah 0,0116 rad. Seluruh nilai teta berada jauh di bawah batas 0,0909 rad (lebih kecil 0,25). Sistem Ganda yang diterapkan mampu memikul 26,24persen gaya lateral gempa pada arah X dan 26,31persen pada arah Y, melampaui syarat minimum 25persen. Elemen struktur seperti balok, kolom, pelat lantai setebal 125 mm, dan shear wall setebal 300 mm dirancang sesuai standar kekuatan dan kekakuan sebesar 73,76persen arah X dan 73,69persen arah Y. Dengan demikian, penerapan Sistem Ganda pada Gedung kantor Universitas Adzkia terbukti efektif, aman, dan relevan untuk pengembangan desain bangunan tahan gempa khususnya Kota Padang
- 30 July 2025
- Published by Universitas Wijaya Kusuma Surabaya in axial : jurnal rekayasa dan manajemen konstruksi
- Vol. 13 (2) , 220-231
Open AccessPERANCANGAN STRUKTUR GEDUNG KANTOR UNIVERSITAS ADZKIA KOTA PADANG DENGAN SISTEM GANDA SESUAI SNI GEMPA 1726:2019
Kota Padang merupakan wilayah dengan tingkat aktivitas seismik yang tinggi, sehingga memerlukan desain struktur bangunan yang adaptif dan andal terhadap beban gempa. Perancangan ini bertujuan merancang struktur Gedung Universitas Adzkia berlantai enam menggunakan Sistem Ganda sesuai ketentuan SNI 1726:2019 dan SNI 2847:2019. Metodologi perancangan meliputi studi literatur untuk menentukan sistem struktur yang tepat, perencanaan awal (preliminary design), pemodelan 3D menggunakan software ETABS v.18 dengan penambahan elemen shear wall, serta analisis struktur terhadap kombinasi pembebanan mengacu pada ketentuan desain Sistem Ganda dan metode dinamik respons spektrum. Hasil analisis menunjukkan bahwa struktur memenuhi seluruh persyaratan desain gempa, dengan faktor koreksi skala terhadap gaya geser dinamis terhadap statis sebesar 1644,98 kN, partisipasi massa melebihi 90persen, simpangan antar lantai di bawah batas 0,002h, serta stabil terhadap pengaruh efek P-Delta. Pada arah X, nilai interstory drift ratio (teta) tertinggi terjadi di lantai 3 sebesar 0,0177 rad dan terendah di atap sebesar 0,0022 rad, sedangkan pada arah Y, nilai tertinggi sebesar 0,0161 rad dan terendah 0,0116 rad. Seluruh nilai teta berada jauh di bawah batas 0,0909 rad (lebih kecil 0,25). Sistem Ganda yang diterapkan mampu memikul 26,24persen gaya lateral gempa pada arah X dan 26,31persen pada arah Y, melampaui syarat minimum 25persen. Elemen struktur seperti balok, kolom, pelat lantai setebal 125 mm, dan shear wall setebal 300 mm dirancang sesuai standar kekuatan dan kekakuan sebesar 73,76persen arah X dan 73,69persen arah Y. Dengan demikian, penerapan Sistem Ganda pada Gedung kantor Universitas Adzkia terbukti efektif, aman, dan relevan untuk pengembangan desain bangunan tahan gempa khususnya Kota Padang
- Open Access
- 4 June 2025
- Published by Politeknik Pratama Purwokerto in Nusantara: Jurnal Pengabdian kepada Masyarakat
- Vol. 5 (3) , 456-474
Perencanaan Desain Musholla Nurul Ikhlas yang Ergonomis, Efisien dan Responsif terhadap Kebutuhan Masyarakat Parak Mujua Kabupaten Solok
The Nurul Ikhlas Mosque, also known as Surau Parak Mujua, located in Pakan Akek, Jorong Kajai, Nagari Koto Baru, Solok Regency, is an important center of religious and social activities for the local community. In June 2023, the mosque suffered a major fire that destroyed the entire structure, creating an urgent need to redesign it to be more functional, ergonomic, efficient, and adaptable to local conditions. This community service project aimed to produce an architectural design that not only met structural and functional needs but also accommodated the social aspirations and cultural values of the local community. The methods used in this project included field observations to understand the community's conditions and needs, participatory discussions with local community leaders to explore aspirations and hopes, technical drawings using AutoCAD software, and structural analysis using ETABS to ensure the building's earthquake resistance. Ergonomics were a key consideration in this design, encompassing circulation flow, room dimensions, natural ventilation, and the selection of materials that were friendly and safe for the elderly, children, and people with disabilities. The output of this activity is a variety of design documents, including floor plans, elevations, building sections, floor plans, columns and beams, and 3D visualizations that can be used as a guide for phased construction. This program demonstrates the importance of collaboration between universities and the community in responding to post-disaster infrastructure needs. This knowledge-based, participatory approach is expected to produce a final design that is appropriate to real needs and the local context, and supports better and more sustainable post-disaster recovery.
- 4 June 2025
- Published by Politeknik Pratama Purwokerto in Nusantara: Jurnal Pengabdian kepada Masyarakat
- Vol. 5 (3) , 456-474
Open AccessPerencanaan Desain Musholla Nurul Ikhlas yang Ergonomis, Efisien dan Responsif terhadap Kebutuhan Masyarakat Parak Mujua Kabupaten Solok
The Nurul Ikhlas Mosque, also known as Surau Parak Mujua, located in Pakan Akek, Jorong Kajai, Nagari Koto Baru, Solok Regency, is an important center of religious and social activities for the local community. In June 2023, the mosque suffered a major fire that destroyed the entire structure, creating an urgent need to redesign it to be more functional, ergonomic, efficient, and adaptable to local conditions. This community service project aimed to produce an architectural design that not only met structural and functional needs but also accommodated the social aspirations and cultural values of the local community. The methods used in this project included field observations to understand the community's conditions and needs, participatory discussions with local community leaders to explore aspirations and hopes, technical drawings using AutoCAD software, and structural analysis using ETABS to ensure the building's earthquake resistance. Ergonomics were a key consideration in this design, encompassing circulation flow, room dimensions, natural ventilation, and the selection of materials that were friendly and safe for the elderly, children, and people with disabilities. The output of this activity is a variety of design documents, including floor plans, elevations, building sections, floor plans, columns and beams, and 3D visualizations that can be used as a guide for phased construction. This program demonstrates the importance of collaboration between universities and the community in responding to post-disaster infrastructure needs. This knowledge-based, participatory approach is expected to produce a final design that is appropriate to real needs and the local context, and supports better and more sustainable post-disaster recovery.
- Open Access
- 7 November 2024
- Published by Fakultas Teknik Universitas Cendrawasih in Jurnal Pengabdian Masyarakat Sains dan Teknologi
- Vol. 3 (4) , 123-137
Pendampingan Masyarakat Nagari Batahan Jorong Sawah Mudik dalam Pembangunan Mesjid Taqwa : Perencanaan dan Desain Mesjid
Taqwa Mosque in Jorong Sawah Mudik, Nagari Batahan Utara, Pasaman Barat Regency, plays a significant role as a center for worship, education, and social activities in the community. However, over time, the mosque's condition has become inadequate to meet the growing needs of its congregation. This study aims to redesign and develop the mosque with an earthquake-resistant structural concept using caisson foundations. The methods employed include data collection, spatial needs analysis, structural design using AutoCAD and ETABS applications, and participatory discussion forums with the local community. The result is an optimal mosque design that considers spatial efficiency, accessibility, and sustainability. This study highlights the importance of community involvement in creating a design that is not only functional but also aligned with local values.
- 7 November 2024
- Published by Fakultas Teknik Universitas Cendrawasih in Jurnal Pengabdian Masyarakat Sains dan Teknologi
- Vol. 3 (4) , 123-137
Open AccessPendampingan Masyarakat Nagari Batahan Jorong Sawah Mudik dalam Pembangunan Mesjid Taqwa : Perencanaan dan Desain Mesjid
Taqwa Mosque in Jorong Sawah Mudik, Nagari Batahan Utara, Pasaman Barat Regency, plays a significant role as a center for worship, education, and social activities in the community. However, over time, the mosque's condition has become inadequate to meet the growing needs of its congregation. This study aims to redesign and develop the mosque with an earthquake-resistant structural concept using caisson foundations. The methods employed include data collection, spatial needs analysis, structural design using AutoCAD and ETABS applications, and participatory discussion forums with the local community. The result is an optimal mosque design that considers spatial efficiency, accessibility, and sustainability. This study highlights the importance of community involvement in creating a design that is not only functional but also aligned with local values.
- Open Access
- 17 September 2024
- Published by Universitas Negeri Padang in CIVED
- Vol. 11 (3) , 1041-1056
Structural Design of a 10-Story Office Building using the Special Moment Frame System (SMFS) in Padang, West Sumatra
Indonesia is located at the convergence of the Eurasian, Pacific, and Indo-Australian tectonic plates, making it prone to significant earthquakes, such as the Aceh earthquake and tsunami in 2004 with a magnitude of 9.1, and the Padang earthquake in 2009 with a magnitude of 7.6, both known for their severe impacts. According to the Central Statistics Agency (BPS), there were 10,843 earthquakes in 2022. Given this high level of risk, all buildings, especially offices, must be designed to be earthquake-resistant due to high activity and user numbers. The city of Padang is categorized in Seismic Design Category D, indicating a high level of earthquake risk. The construction of a ten-story reinforced concrete building for office use is planned, referring to SNI 1726-2019 on earthquake resistance and SNI 1727-2020 on minimum loads, along with the Special Moment Resisting Frame System (SMRF). Structural analysis and modeling are conducted using ETABS software, with element dimensions based on the initial design. This analysis aims to ensure the building meets earthquake resistance requirements through response spectrum evaluation, including natural periods, inter-story drift, P-Delta effects, and checks for irregularities. Based on internal forces from ETABS V.18, reinforcement designs are prepared for structural elements such as columns, beams, slabs, and shear walls. A design capacity evaluation ensures the safety and optimal performance of the structure during an earthquake.
- 17 September 2024
- Published by Universitas Negeri Padang in CIVED
- Vol. 11 (3) , 1041-1056
Open AccessStructural Design of a 10-Story Office Building using the Special Moment Frame System (SMFS) in Padang, West Sumatra
Indonesia is located at the convergence of the Eurasian, Pacific, and Indo-Australian tectonic plates, making it prone to significant earthquakes, such as the Aceh earthquake and tsunami in 2004 with a magnitude of 9.1, and the Padang earthquake in 2009 with a magnitude of 7.6, both known for their severe impacts. According to the Central Statistics Agency (BPS), there were 10,843 earthquakes in 2022. Given this high level of risk, all buildings, especially offices, must be designed to be earthquake-resistant due to high activity and user numbers. The city of Padang is categorized in Seismic Design Category D, indicating a high level of earthquake risk. The construction of a ten-story reinforced concrete building for office use is planned, referring to SNI 1726-2019 on earthquake resistance and SNI 1727-2020 on minimum loads, along with the Special Moment Resisting Frame System (SMRF). Structural analysis and modeling are conducted using ETABS software, with element dimensions based on the initial design. This analysis aims to ensure the building meets earthquake resistance requirements through response spectrum evaluation, including natural periods, inter-story drift, P-Delta effects, and checks for irregularities. Based on internal forces from ETABS V.18, reinforcement designs are prepared for structural elements such as columns, beams, slabs, and shear walls. A design capacity evaluation ensures the safety and optimal performance of the structure during an earthquake.