    The effect of magnetic resonance image slice thickness and voxel geometry on digital dental implant planning: an in vitro study

    by Hian Parize, Fábio Munhoz, Carlos Cordeiro, Norbert Meier, Johannes Kleinheinz, Dalva Cruz Laganá, Newton Sesma, Lauren Bohner

    Objectives: To evaluate the effect of magnetic resonance imaging (MRI) slice thickness and voxel geometry on digital dental implant planning compared to cone-beam computed tomography (CBCT). Methods: Edentulous phantoms were scanned using CBCT and two MRI protocols: anisotropic and isotropic. Two calibrated examiners digitally planned the position of four implants for each sample ( n = 8) per exam (CBCT, anisotropic and isotropic). Diagnostic accuracy was assessed using implant angular deviation and linear measurements. Image quality was evaluated using a questionnaire regarding visualization of anatomical structures. Cost-to-planning-time ratio was assessed by exam costs per minute of planning. The Friedman and Wilcoxon tests were used to evaluate differences in diagnostic accuracy, planning time, and cost-to-planning-time ratio. Image quality ratings on a 5-point scale were classified as non-valid (≤ 2) or valid (≥ 3) for clinical use. Reliability was assessed by percentage agreement, and differences were evaluated using the chi-square test. Results: A total of 96 implants were planned, with 32 in each exam. No significant differences were observed between exams for angular deviation ( p > 0.197), linear measurements ( p > 0.305), image quality ( p > 0.132), or planning time ( p = 0.093). However, CBCT had lower cost-to-planning-time ratio than anisotropic and isotropic MRI ( p = 0.012), which did not differ from each other ( p = 1.000). Inter-examiner agreement on image quality for anisotropic and isotropic MRI varied widely, with lower ratings for the mandibular nerve canal. Conclusion: No statistically significant differences were detected among the imaging protocols in diagnostic accuracy or image quality under the investigated in vitro conditions.

  • Open Access

    Nutritional conditions in oral squamous cell carcinoma patients –prospective longitudinal observational study

    by Caroline Wurche, Julia Wirth, Johannes Kleinheinz, Lauren Bohner, Sonja Sielker

    Background: Cancer-related malnutrition is an often-disregarded problem with a lack of knowledge and standards concerning diagnosis and therapy. Patients with oral squamous cell cancer can suffer not only from metabolic factors but also from aggravated oral food intake. This study examines the issue of malnutrition in patients with oral squamous cell carcinoma (OSCC) before diagnosis and under treatment. Methods: The nutritional status of 30 patients with OSCC was registered before and after surgical treatment, with a time interval of 16 weeks. The methods applied were body mass index (BMI), subjective global assessment (SGA) and bioelectrical impedance analysis (BIA). The reference group consisted of 30 patients planned for orthognathic surgery. Equal for both groups were postoperative nasogastric tube feeding. The data for the OSCC patients were analysed and tested for significance at the level of p = 0.05. Results: Preoperative malnutrition, as expected, was only detected in the OSCC group. Only 6% of OSCC patients start with a good nutritional status, but this increases to nearly 50% during therapy, although two patients ended up with severe malnutrition. Nonetheless, 40% of the reference group were malnourished after the first week, according to the SGA. The nutritional status improved during therapy to a good status in nearly all cases. Conclusion: Malnutrition is a relevant problem in patients with OSCC due to the high prevalence in this population, which was confirmed by these data. Appropriate diagnostic tools and an adapted treatment concept in terms of application form and ingredients, as well as supplements, should be an integral part of the treatment concept for these patients. Additionally, the data from these studies recommend that patients who are preoperatively healthy and have temporary postoperative restrictions on oral food intake be provided with an adequate nutrient supply. An important component of nutritional interventions should be the long-term prevention of skeletal muscle loss.

  • Open Access

    Bone quality assessment around dental implants in cone-beam CT images: effect of rotation mode and metal artefact reduction tool

    by Lauren Bohner, Hian Parize, João Victor Cunha Cordeiro, Natalia Koerich Laureano, Johannes Kleinheinz, Ricardo Armini Caldas, Dorothea Dagassan-Berndt

    Objectives: The purpose of this study was to evaluate how artefacts caused by titanium and zirconia dental implants affect the bone quality assessment in CBCT images. The effect of scan mode and the use of metal artefact reduction (MAR) algorithm on artefacts suppression were taken in consideration. Methods: Titanium and zirconia dental implants were installed in porcine bone samples and scanned with two CBCT devices with adjustments on scan mode and with the use of MAR. The control group consisted of bone sample without implant and scanned with full-rotation scan mode without MAR. Artefacts extension and bone quality around implants were measured by deviation of grey values and bone histomorphometry measurements (trabecular volume fraction, bone specific surface, trabecular thickness, and trabecular separation), respectively. Mean difference among groups was assessed by within ANOVA with Bonferroni correction. Correlation between bone quality measurements acquired in the experimental and control groups was assessed by Spearman correlation test (α = .05). Results: No statistical difference was found for artefacts extension in images acquired by half and full-rotation modes (P = .82). The application of MAR reduced artefacts caused by titanium and zirconia dental implants, showing no statistically significant difference from the control group (titanium: P = .20; zirconia: P = .31). However, there was no correlation between bone quality measurements (P < .05). Conclusions: Bone quality assessment was affected by the presence of artefacts caused by dental implants. Rotation mode did not affect the appearance of artefacts and bone qualitative measurements. MAR was able to decrease artefacts, however, it did not improve the accuracy of bone quality measurements.