Abstract
Objectives: To evaluate the effect of magnetic resonance imaging (MRI) slice thickness and voxel geometry on digital dental implant planning compared to cone-beam computed tomography (CBCT). Methods: Edentulous phantoms were scanned using CBCT and two MRI protocols: anisotropic and isotropic. Two calibrated examiners digitally planned the position of four implants for each sample ( n = 8) per exam (CBCT, anisotropic and isotropic). Diagnostic accuracy was assessed using implant angular deviation and linear measurements. Image quality was evaluated using a questionnaire regarding visualization of anatomical structures. Cost-to-planning-time ratio was assessed by exam costs per minute of planning. The Friedman and Wilcoxon tests were used to evaluate differences in diagnostic accuracy, planning time, and cost-to-planning-time ratio. Image quality ratings on a 5-point scale were classified as non-valid (≤ 2) or valid (≥ 3) for clinical use. Reliability was assessed by percentage agreement, and differences were evaluated using the chi-square test. Results: A total of 96 implants were planned, with 32 in each exam. No significant differences were observed between exams for angular deviation ( p > 0.197), linear measurements ( p > 0.305), image quality ( p > 0.132), or planning time ( p = 0.093). However, CBCT had lower cost-to-planning-time ratio than anisotropic and isotropic MRI ( p = 0.012), which did not differ from each other ( p = 1.000). Inter-examiner agreement on image quality for anisotropic and isotropic MRI varied widely, with lower ratings for the mandibular nerve canal. Conclusion: No statistically significant differences were detected among the imaging protocols in diagnostic accuracy or image quality under the investigated in vitro conditions.
Funding Information
  • Universidade de São Paulo

This publication has 33 references indexed in Scilit: