Steffen Schlegel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Steffen Schlegel has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Dirk Westermann
Power Systems Group, Technische Universität Ilmenau, Ilmenau, Germany
8 shared publications - Teng Jiang
School of Electronics and Information, Zhengzhou University of Aeronautics, Zhengzhou, China
3 shared publications - Hui Cai
Ilmenau University of Technology , Ilmenau , Germany
2 shared publications - Xinya Song
Power System Group, TU Ilmenau, Ilmenau, Germany
2 shared publications - Alexander Novitskiy
Power Systems Department, Faculty of Electrical Engineering and Information Technology at the Ilmenau University of Technology, P.O.B. 100565, D-98684, Ilmenau, Germany
1 shared publication Alexander Raab
Institute of Electrical Energy Systems, Friedrich-Alexander-Universitt Erlangen-Nrnberg (FAU),Erlangen,Germany
1 shared publication
Latest Publications
- 1 November 2025
- Published by Walter de Gruyter GmbH in at - Automatisierungstechnik
- Vol. 73 (11) , 842-853
Field implementation of reactive power management in the congestion management process redispatch 2.0 – methods and findings
The short-term procurement of reactive power is becoming increasingly important, calling for more intensive coordination between grid operators due to local optimization challenges. The German congestion management instrument Redispatch 2.0 provides a platform for such coordination processes. This paper presents an approach and first field test results for extending Redispatch 2.0 by reactive power to provide it from the distribution grid at the point of common coupling to use it for voltage stability in the transmission grid. The results show the potential of expansion and at the same time the challenges that arise in terms of reliable reactive power provision.
- 1 November 2025
- Published by Walter de Gruyter GmbH in at - Automatisierungstechnik
- Vol. 73 (11) , 842-853
Field implementation of reactive power management in the congestion management process redispatch 2.0 – methods and findings
The short-term procurement of reactive power is becoming increasingly important, calling for more intensive coordination between grid operators due to local optimization challenges. The German congestion management instrument Redispatch 2.0 provides a platform for such coordination processes. This paper presents an approach and first field test results for extending Redispatch 2.0 by reactive power to provide it from the distribution grid at the point of common coupling to use it for voltage stability in the transmission grid. The results show the potential of expansion and at the same time the challenges that arise in terms of reliable reactive power provision.
- Open Access
Levelized Cost of Electricity for Electric Vehicle Charging in Off-Grid Solar-Powered Microgrid: A Practical Case Study
The number of electric vehicles is constantly increasing in Europe and around the world. Providing a reliable charging infrastructure for the se vehicles is a major challenge for distribution grid operators. Off-grid microgrids have become a promising solution to this challenge, using renewable energy sources such as solar power to meet the demand in a sustainable way. This paper presents a practical study of a solar-powered microgrid operating at a university campus in Ilmenau, Germany, aimed at supporting electric vehicle (EV) charging at public workplaces. The system includes eight charging stations and utilizes renewable energy to reduce grid dependency. Statistical methods, including distribution functions, medians, and mean values, were applied to classify and evaluate the dataset to analyze energy generation and variable load patterns, as well as system performance. The results show that the Ilmenau microgrid can meet EV charging demand during the warm season but underperform during the cold season. An economic analysis determined costs of EUR 0.58/kWh based on pre-2020 component prices and EUR 0.46/kWh based on 2025 market prices. The calculated annual cost per employee is EUR 308.29 over a 20-year period. Increasing energy storage was found to be neither cost-effective nor operationally beneficial. The scalability of the microgrid to larger workplaces is investigated, and recommendations for system improvements are provided.
Open AccessLevelized Cost of Electricity for Electric Vehicle Charging in Off-Grid Solar-Powered Microgrid: A Practical Case Study
The number of electric vehicles is constantly increasing in Europe and around the world. Providing a reliable charging infrastructure for the se vehicles is a major challenge for distribution grid operators. Off-grid microgrids have become a promising solution to this challenge, using renewable energy sources such as solar power to meet the demand in a sustainable way. This paper presents a practical study of a solar-powered microgrid operating at a university campus in Ilmenau, Germany, aimed at supporting electric vehicle (EV) charging at public workplaces. The system includes eight charging stations and utilizes renewable energy to reduce grid dependency. Statistical methods, including distribution functions, medians, and mean values, were applied to classify and evaluate the dataset to analyze energy generation and variable load patterns, as well as system performance. The results show that the Ilmenau microgrid can meet EV charging demand during the warm season but underperform during the cold season. An economic analysis determined costs of EUR 0.58/kWh based on pre-2020 component prices and EUR 0.46/kWh based on 2025 market prices. The calculated annual cost per employee is EUR 308.29 over a 20-year period. Increasing energy storage was found to be neither cost-effective nor operationally beneficial. The scalability of the microgrid to larger workplaces is investigated, and recommendations for system improvements are provided.
- Open Access
- 13 December 2024
- Published by Springer Nature in e+i Elektrotechnik und Informationstechnik
- Vol. 141 (7-8) , 421-430
Reactive power redispatch at the TSO-DSO interface: analysis of the challenges and differences for processual integration
The increasing challenge of maintaining voltage due to reduced reliable reactive power potentials in the transmission grid requires a fast and economically optimal consideration of reactive power in the congestion management processes of transmission system operators. Established processes such as the German Redispatch 2.0 process adjust the dispatch of plants to avoid congestion but do not make use of available reactive power potentials to avoid voltage-related congestion. This work evaluates the suitability of existing processes for application to reactive power. Using a realistic distribution grid, the procedural Redispatch 2.0 specifications for clustering reactive power are applied. It can be shown that the determination of reliable reactive power capability is associated with more dependencies and influencing factors than with active power. This leads to the need for a separate cluster concept and, due to the operating point dependency, for a procedure coordinated with the grid situation.
- 13 December 2024
- Published by Springer Nature in e+i Elektrotechnik und Informationstechnik
- Vol. 141 (7-8) , 421-430
Open AccessReactive power redispatch at the TSO-DSO interface: analysis of the challenges and differences for processual integration
The increasing challenge of maintaining voltage due to reduced reliable reactive power potentials in the transmission grid requires a fast and economically optimal consideration of reactive power in the congestion management processes of transmission system operators. Established processes such as the German Redispatch 2.0 process adjust the dispatch of plants to avoid congestion but do not make use of available reactive power potentials to avoid voltage-related congestion. This work evaluates the suitability of existing processes for application to reactive power. Using a realistic distribution grid, the procedural Redispatch 2.0 specifications for clustering reactive power are applied. It can be shown that the determination of reliable reactive power capability is associated with more dependencies and influencing factors than with active power. This leads to the need for a separate cluster concept and, due to the operating point dependency, for a procedure coordinated with the grid situation.
- 18 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Positive Sequence Impedances of LV Sector-Shaped Cables in the Frequency Range 2 to 9 kHz
The development of modern LV distribution networks is characterized by the growth in the number of converter-interfaced prosumers using electronic elements with switching frequencies in the kHz range. It causes the emission of so-called “supraharmonics” into electrical networks. For the analysis of the propagation of supraharmonics it is necessary to known the corresponding frequency-dependent parameters of LV distribution lines. Modern LV distribution lines are mainly cable lines and designed for the operation at the fundamental frequency (e.g. 50 Hz). The calculation of line impedances at all other frequencies is the subject of special studies. The paper deals with the analysis of positive sequence series impedances of LV sector-shaped cables in the frequency range 2 to 9 kHz. The analysis is based on FEM simulation results. Novel formulas are suggested for the simplified determination of series resistances and inductances of LV 4-core cables with sector-shaped aluminium conductors.
- 18 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Positive Sequence Impedances of LV Sector-Shaped Cables in the Frequency Range 2 to 9 kHz
The development of modern LV distribution networks is characterized by the growth in the number of converter-interfaced prosumers using electronic elements with switching frequencies in the kHz range. It causes the emission of so-called “supraharmonics” into electrical networks. For the analysis of the propagation of supraharmonics it is necessary to known the corresponding frequency-dependent parameters of LV distribution lines. Modern LV distribution lines are mainly cable lines and designed for the operation at the fundamental frequency (e.g. 50 Hz). The calculation of line impedances at all other frequencies is the subject of special studies. The paper deals with the analysis of positive sequence series impedances of LV sector-shaped cables in the frequency range 2 to 9 kHz. The analysis is based on FEM simulation results. Novel formulas are suggested for the simplified determination of series resistances and inductances of LV 4-core cables with sector-shaped aluminium conductors.
- 6 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Steady-State and Dynamic Security Assessment for System Operation
This contribution provides the implementation of a holistic operational security assessment process for both steady-state security and dynamic stability. The merging of steady-state and dynamic security assessment as a sequential process is presented. A steady-state and dynamic modeling of a VSC-HVDC was performed including curative and stabilizing measures as remedial actions. The assessment process was validated by a case study on a modified version of the Nordic 32 system. Simulation results showed that measure selection based on purely steady-state contingency analysis can lead to loss of stability in time domain. A subsequent selection of measures on the basis of the dynamic security assessment was able to guarantee the operational security for the stationary N-1 scenario as well as the power system stability.
- 6 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Steady-State and Dynamic Security Assessment for System Operation
This contribution provides the implementation of a holistic operational security assessment process for both steady-state security and dynamic stability. The merging of steady-state and dynamic security assessment as a sequential process is presented. A steady-state and dynamic modeling of a VSC-HVDC was performed including curative and stabilizing measures as remedial actions. The assessment process was validated by a case study on a modified version of the Nordic 32 system. Simulation results showed that measure selection based on purely steady-state contingency analysis can lead to loss of stability in time domain. A subsequent selection of measures on the basis of the dynamic security assessment was able to guarantee the operational security for the stationary N-1 scenario as well as the power system stability.
- 31 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A Practical Approach to Construct a Digital Twin of a Power Grid using Harmonic Spectra
The electrical energy system is transforming itself into a sustainable energy supply in response to the decline in fossil fuels. This conversion is driving the expansion of renewable energy facilities such as photovoltaic plants and wind power plants. Except for large hydropower plants and offshore wind farms, the integration of renewable energies takes place predominantly in the medium- and low-voltage distribution networks. This leads to a lack of observability and increasing grid complexity. Consequently, distribution network operators are constantly faced with a challenge in terms of observability. A comprehensive installation of measuring instruments in the medium- and low-voltage networks has proved economically unviable. An alternative approach to network state monitoring within the framework of power grid digital twin (DT) is therefore developed in this paper. The patterns of the electrical energy system are detected and modeled employing an artificial neural network (ANN) in connection with the associated harmonic spectra. Based on this DT model, the active powers of renewable energy facilities are estimated through the measured voltage data. In this regard, this work is first devoted to the modeling of an ANN-based DT estimator. The proposed power state estimation is then validated with the measured data from a field test. The accuracy of the estimation will be investigated according to the different influencing factors.
- 31 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A Practical Approach to Construct a Digital Twin of a Power Grid using Harmonic Spectra
The electrical energy system is transforming itself into a sustainable energy supply in response to the decline in fossil fuels. This conversion is driving the expansion of renewable energy facilities such as photovoltaic plants and wind power plants. Except for large hydropower plants and offshore wind farms, the integration of renewable energies takes place predominantly in the medium- and low-voltage distribution networks. This leads to a lack of observability and increasing grid complexity. Consequently, distribution network operators are constantly faced with a challenge in terms of observability. A comprehensive installation of measuring instruments in the medium- and low-voltage networks has proved economically unviable. An alternative approach to network state monitoring within the framework of power grid digital twin (DT) is therefore developed in this paper. The patterns of the electrical energy system are detected and modeled employing an artificial neural network (ANN) in connection with the associated harmonic spectra. Based on this DT model, the active powers of renewable energy facilities are estimated through the measured voltage data. In this regard, this work is first devoted to the modeling of an ANN-based DT estimator. The proposed power state estimation is then validated with the measured data from a field test. The accuracy of the estimation will be investigated according to the different influencing factors.
- 1 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Modeling Power-to-Gas in the Electrical Energy System in Real-Time Simulator
One solution to compensate for fluctuations in renewable energy sources is the use of power-to-gas (PtG) systems. These convert excess energy from the power grid into synthetic gases that can either be stored or used directly in other energy sectors. The PtG system, therefore, represents an interface between the electrical energy and gas sectors and enables energy transfer between the two. Furthermore, seasonal load fluctuations in the power grid are compensated, e.g. excess solar energy from the summer months can be stored in the form of gas and converted back into electricity in winter if necessary. As part of the work, we develop a simulation model for the modelling of PtG systems in the electrical energy system. This initially requires extensive literature research to characterize the various modules of PtG systems. These include the electrolysis of water, the methanation of hydrogen, the modelling of gas storage and the regeneration of synthetic gases via fuel cells or gas power plants. The model is intended to provide essential insights into the dynamic behavior of PtG systems to determine their suitability for the provision of secondary control power. Furthermore, the model is to be used to create a basis for an economic evaluation of various implementation options for PtG plants.
- 1 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Modeling Power-to-Gas in the Electrical Energy System in Real-Time Simulator
One solution to compensate for fluctuations in renewable energy sources is the use of power-to-gas (PtG) systems. These convert excess energy from the power grid into synthetic gases that can either be stored or used directly in other energy sectors. The PtG system, therefore, represents an interface between the electrical energy and gas sectors and enables energy transfer between the two. Furthermore, seasonal load fluctuations in the power grid are compensated, e.g. excess solar energy from the summer months can be stored in the form of gas and converted back into electricity in winter if necessary. As part of the work, we develop a simulation model for the modelling of PtG systems in the electrical energy system. This initially requires extensive literature research to characterize the various modules of PtG systems. These include the electrolysis of water, the methanation of hydrogen, the modelling of gas storage and the regeneration of synthetic gases via fuel cells or gas power plants. The model is intended to provide essential insights into the dynamic behavior of PtG systems to determine their suitability for the provision of secondary control power. Furthermore, the model is to be used to create a basis for an economic evaluation of various implementation options for PtG plants.
- 1 January 2019
- Published by Institution of Engineering and Technology (IET)
- p. 91 (5 pp.)
Coupling of HV Distributions Systems through multiple point-to-point-DC-connections
This paper deals with the possibility of coupling distribution networks by using point-to-point DC links. The advantages of this approach are due to the improved integration of RES in distribution networks through a direct compensation of Generation and load in the same voltage level. A method was proposed which allows a direct transport of the excess power from one distribution network to another distribution network with transit through an intermediate distribution network with a simple coordination effort. The method is only dependent on power flow measurements in the own distribution network and therefore does not require an additional coordinating instance. The DC links could thus work autonomously as far as possible. In a case study it could be shown that the approach has advantages with regard to system losses as well as relief of the coupling points to the overlayed transmission network in comparison to the previous power extension in AC transmission lines. However, the case study also showed that the method had to be further improved regarding network security.
- 1 January 2019
- Published by Institution of Engineering and Technology (IET)
- p. 91 (5 pp.)
Coupling of HV Distributions Systems through multiple point-to-point-DC-connections
This paper deals with the possibility of coupling distribution networks by using point-to-point DC links. The advantages of this approach are due to the improved integration of RES in distribution networks through a direct compensation of Generation and load in the same voltage level. A method was proposed which allows a direct transport of the excess power from one distribution network to another distribution network with transit through an intermediate distribution network with a simple coordination effort. The method is only dependent on power flow measurements in the own distribution network and therefore does not require an additional coordinating instance. The DC links could thus work autonomously as far as possible. In a case study it could be shown that the approach has advantages with regard to system losses as well as relief of the coupling points to the overlayed transmission network in comparison to the previous power extension in AC transmission lines. However, the case study also showed that the method had to be further improved regarding network security.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 540-544
Research on Cross-Regional Interaction in Converter-Dominated Distribution Grids
Today's electrical power system is subjected to changes and improvements. In distribution grids, the number of converters, which connect the energy devices to the grid, is dramatically increased. The objective of this paper is to analyze the destabilization effect on system stability with increasing number of converter. Coinstantaneous this paper also developed a feasible solution by an enhancement of the converter control structure and an operation point dependent stabilizing factor. The results are demonstrated with Cigré benchmark grid in effective value time domain.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 540-544
Research on Cross-Regional Interaction in Converter-Dominated Distribution Grids
Today's electrical power system is subjected to changes and improvements. In distribution grids, the number of converters, which connect the energy devices to the grid, is dramatically increased. The objective of this paper is to analyze the destabilization effect on system stability with increasing number of converter. Coinstantaneous this paper also developed a feasible solution by an enhancement of the converter control structure and an operation point dependent stabilizing factor. The results are demonstrated with Cigré benchmark grid in effective value time domain.